Lenze E82CV251K2C
Replaced by a bare metal cooling plate connected to a separate customer-side
Genuine surplus Lenze E82CV251K2C cold-plate inverter: 0.25 kW, 1.7 A, IP20. Verified condition and practical sourcing support from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated motor power | 0.25 kW typical (4-pole three-phase asynchronous motor) |
|---|---|
| Rated output current | 1.7 A nominal at 8 kHz switching frequency |
| Max. output current | 2.5 A for 60 s (1 min overload at Imax / 2 min base load at 75% Ir) |
| Supply voltage | 1/N/PE AC 180 V -0% … 264 V +0%; 45 … 65 Hz |
| Protection rating | IP20 |
| Operating temperature | -10 … +55 °C (derated by 2.5%/°C above +40 °C) |
| Storage temperature | -25 … +60 °C |
| Relative humidity | Average 85 % RH, without condensation (climatic class 3K3 per EN 50178) |
| Built-in ports | X3 control terminal strip (analog/digital I/O) |
| Communication expansion | FIF slot for plug-in function modules (E82ZAF* family) |
Description
What happens when a standard heatsink inverter cannot fit the enclosure or the ambient airflow is unreliable? The Lenze E82CV251K2C answers that problem with cold-plate technology. This genuine surplus 8200 vector unit is a 0.25 kW frequency inverter whose heatsink is replaced by a bare metal cooling plate for a customer-side cooler. Maintenance teams and panel builders choose verified surplus here because the cold-plate special design remains available on request while standard-body alternatives differ mechanically.
Product Overview: Cold-Plate Inverter in the 8200 vector Family
The E82CV251K2C belongs to the Lenze 8200 vector series, a long-established drive family for three-phase asynchronous motors. In this special design, the heatsink is removed and replaced by a bare metal cooling plate. Heat leaves through that plate into a separate customer-side cooler rather than through cabinet air. Consequently, the inverter suits enclosures where forced air is impractical or where heat must be routed away from sensitive electronics. Rated motor power is 0.25 kW typical for a 4-pole motor, and rated output current is 1.7 A nominal at 8 kHz switching frequency. Control supports V/f characteristic (linear or quadratic) and sensorless vector control, with an output frequency range of -650 to +650 Hz. An integrated brake transistor is included.

Technical Specs Breakdown: What the Numbers Mean in Practice
Three figures matter most during selection. First, the supply voltage of 1/N/PE AC 180 V -0% to 264 V +0% at 45 to 65 Hz covers single-phase industrial networks with generous tolerance. Second, the 2.5 A maximum output current for 60 s supports a periodic load cycle of 1 min overload at Imax followed by 2 min base load at 75% Ir. Third, cold-plate thermal data sets dissipated power loss at 15 W, thermal resistance Rth ≤ 1.5 K/W between cooler and cooling medium, and a maximum permissible cooling-plate temperature of 75 °C. The protection rating is IP20, and operating temperature spans -10 to +55 °C with derating of 2.5%/°C above +40 °C. Built-in I/O on the X3 control terminal strip includes one analog input, one analog output, four digital inputs, one digital output, and one relay output with changeover contact rated 250 V AC / 3 A. No fieldbus protocol is built in; the FIF slot accepts E82ZAF* plug-in function modules.

Surplus Advantage: Why a Verified Refurbished Unit Fits This Model
Lenze lists the 8200 vector among its previous products, and the cold-plate special design is available on request. There is no drop-in same-order-code replacement; Lenze confirms a migration path to the i950, which emulates 8200 vector behaviour via an i950 PROFIBUS module and the L_ICIP library. For a running machine, that migration means engineering work. A genuine surplus or refurbished unit keeps the existing drive architecture in place. Autronexa verifies units against OEM datasheet markings and part-number cross-reference, and refurbished stock is tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Lenze E82CV251K2C, or a clone or copy?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before listing. The E82CV251K2C is supplied as a genuine Lenze 8200 vector cold-plate inverter, not a copy.
What condition will the E82CV251K2C arrive in?
Units are supplied in the condition stated at the time of order, typically refurbished. Refurbished stock is tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the current condition grading of available units.
How fast can you ship the E82CV251K2C?
Lead time depends on current stock. Contact Autronexa for current lead time and availability; surplus and refurbished units are ready to ship once verified.
Does the E82CV251K2C support fieldbus communication?
No fieldbus protocol is built in. The FIF slot accepts E82ZAF* plug-in function modules for communication expansion, and the X3 control terminal strip provides analog and digital I/O.
Is the E82CV251K2C still supported by Lenze?
Lenze lists the 8200 vector among its previous products, and the cold-plate special design is available on request. There is no drop-in same-order-code replacement; Lenze confirms an i950 migration path. Contact Autronexa to verify OEM support status for your application.
Related & compatible parts
Lenze
E94AZPS0034N
Genuine Lenze E94AZPS0034N passive installation backplane for 9400 Single Drive axis modules, without brake module. Verified surplus and…
Lenze
E82EV113-4C200
Genuine surplus Lenze E82EV113-4C200 frequency inverter with 11.0 kW rating and RS232/485 system bus — verified condition, ready…
Lenze
E94ASHE0864
Genuine surplus Lenze E94ASHE0864 axis module: 45 kW, 86 A rated output, CANopen onboard, IP20. Verified condition and…
Lenze
E82CV222K4C
Genuine surplus Lenze E82CV222K4C cold-plate inverter: 2.2 kW, 5.6 A, IP20. Verified condition and practical sourcing support from…
News & guides for Lenze
Lenze spare parts: buying guide, series overview and how to order
Lenze spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…