Lenze E82CV223K4B201
Replaced by a bare metal cooling plate connected to a separate customer-side
Genuine surplus Lenze E82CV223K4B201 cold-plate inverter: 22 kW, 47 A, IP20. Verified condition and practical sourcing support from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated motor power | 22.0 kW typical (4-pole three-phase asynchronous motor) |
|---|---|
| Rated output current | 47 A nominal at 8 kHz switching frequency |
| Max. output current | 70.5 A for 60 s (1 min overload at Imax / 2 min base load at 75% Ir) |
| Supply voltage | 3/PE AC 320 V -0% … 550 V +0%; 45 … 65 Hz |
| Control | V/f characteristic control (linear/quadratic) and sensorless vector control; output frequency -650 … +650 Hz |
| Built-in I/O | 1 analog input, 1 analog output, 4 digital inputs, 1 digital output, 1 relay output (changeover contact, 250 V AC / 3 A) |
| Cooling-plate thermal data | Dissipated power loss 610 W; Rth ≤ 0.057 K/W; max. permissible cooling-plate temperature 75 °C |
| Operating temperature | -10 … +50 °C (derated by 2.5%/°C above +40 °C) |
| Protection rating | IP20 |
Description
When a standard air-cooled drive will not fit a sealed cabinet, the Lenze E82CV223K4B201 cold-plate frequency inverter solves the thermal problem directly. This 8200 vector unit delivers 22.0 kW typical motor power with the heatsink replaced by a bare metal cooling plate for a customer-side cooler. Autronexa supplies genuine surplus and refurbished units with verified condition, giving maintenance teams a practical alternative to long OEM lead times.
What the Cold-Plate Design Solves
Heat buildup inside enclosed panels is the first pain point this model addresses. Instead of dissipating heat into the cabinet air, the E82CV223K4B201 transfers it through a bare metal plate to an external cooling circuit. The published thermal data makes this predictable: dissipated power loss is 610 W, thermal resistance Rth is ≤ 0.057 K/W between cooler and cooling medium, and the maximum permissible cooling-plate temperature is 75 °C. For panel builders, that means the cooling load moves outside the enclosure rather than adding to it. The unit is rated IP20 and operates from -10 … +50 °C, derated by 2.5%/°C above +40 °C. Storage temperature spans -25 … +60 °C, and relative humidity averages 85 % RH without condensation.

Electrical Performance and Control
Matching a drive to an existing motor is the second pain point. This unit is rated 47 A nominal output current at 8 kHz switching frequency, with 70.5 A maximum output current for 60 s. That overload follows a periodic load cycle of 1 min at Imax and 2 min base load at 75% Ir. Supply voltage is 3/PE AC 320 V -0% … 550 V +0% at 45 … 65 Hz. Control covers V/f characteristic control (linear/quadratic) and sensorless vector control, with an output frequency range of -650 … +650 Hz. An integrated brake transistor is included. Built-in I/O comprises 1 analog input, 1 analog output, 4 digital inputs, 1 digital output, and 1 relay output with a changeover contact rated 250 V AC / 3 A, all via the X3 control terminal strip.

Sourcing a Legacy Drive Without Guesswork
Finding a genuine replacement for a legacy 8200 vector unit is the third pain point. Lenze lists this series among its previous products, and the cold-plate special design is available on request. There is no drop-in same-order-code replacement; Lenze confirms a migration path to the i950, which emulates 8200 vector behaviour via the i950 PROFIBUS module and L_ICIP library. For like-for-like maintenance, a verified surplus unit keeps the existing panel design and wiring concept intact. Autronexa verifies units against OEM datasheet markings and part-number cross-reference, then reports condition and current availability before you commit. Note that no fieldbus protocol is built in; the FIF slot accepts plug-in function modules from the E82ZAF* family. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Lenze E82CV223K4B201, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. The E82CV223K4B201 is supplied as a genuine Lenze 8200 vector cold-plate inverter, not a copy.
What condition will the E82CV223K4B201 arrive in?
Units are supplied refurbished as the site default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the specific condition grade of current stock.
How fast can you ship the E82CV223K4B201?
Lead time depends on current verified stock. Contact Autronexa with your part number for verified condition and current availability before placing an order.
Does the E82CV223K4B201 include a built-in fieldbus port?
No. Protocols are not built in; fieldbus communication requires a plug-in function module in the FIF slot, from the E82ZAF* family. The built-in X3 terminal strip provides analog and digital I/O.
Is the E82CV223K4B201 still supported by Lenze?
Lenze lists the 8200 vector series among its previous products, and the cold-plate special design is available on request. Lenze confirms a migration path to the i950. Contact Autronexa to verify OEM support status for your application.
Related & compatible parts
Lenze
E82CV222K4C
Genuine surplus Lenze E82CV222K4C cold-plate inverter: 2.2 kW, 5.6 A, IP20. Verified condition and practical sourcing support from…
Lenze
E82CV371K2C
Genuine surplus Lenze E82CV371K2C cold-plate inverter, 0.37 kW, verified condition and clear lead times from Autronexa.
Lenze
E70ACPSE0304S
Genuine surplus Lenze E70ACPSE0304S i700 power supply module: 400 V AC input, 30 A output, 10.3 kW rated,…
Lenze
E82CV402K4C
Genuine surplus Lenze E82CV402K4C cold-plate inverter: 4.0 kW, 9.5 A, 320–550 V AC, IP20. Verified condition and practical…
News & guides for Lenze
Lenze spare parts: buying guide, series overview and how to order
Lenze spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…