General Electric IC697CPU731
Series 90-70 IC697CPU731 CPU
Genuine surplus GE Fanuc IC697CPU731 CPU for Series 90-70 PLCs, verified and refurbished with 512 mixed I/O capacity.
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
Technical specifications
| Series | Series 90-70 |
|---|---|
| Product Type | PLC CPU |
| Microprocessor Type | 80C186 Microprocessor |
| Maximum I/O | 512 (any mix) |
| Maximum Analog I/O | 8000 |
| Real-Time Application Control | Supported |
| Remote Module Control | Supported |
| Communication | Through the Backplane |
Description
The General Electric IC697CPU731 is a Series 90-70 single-slot CPU that processes data from up to 512 inputs and outputs in any mix. It suits maintenance teams needing a verified surplus or refurbished unit to keep a 90-70 PLC running without waiting on OEM lead times.
What this controller CPU Does in a Series 90-70 System
This module is the processing core of a Series 90-70 PLC rack. It uses an 80C186 microprocessor and communicates with I/O and smart option modules through the backplane, so no separate communication cabling is required for rack-level data exchange. The CPU supports real-time application control and remote module control, and it can be programmed with DOS or Windows-based software. Data and program memory are user-configurable. Because it occupies a single slot, it fits baseplates where slot count is tight. The unit must be installed with the PLC powered off, and its battery must be connected to one of the battery connectors before operation.

Why Choose Surplus or Refurbished for This CPU
A failed CPU halts the whole rack, and OEM lead times for legacy Series 90-70 hardware can stretch well beyond a planned maintenance window. Autronexa supplies genuine surplus and refurbished this controller units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. That gives you a practical path to restore processing capability without redesigning the control system. Each unit is checked for correct model marking and revision before dispatch, and condition is confirmed in writing so your maintenance planner knows exactly what will arrive.

this controller vs Other Series 90-70 CPUs
Buyers comparing 90-70 CPUs should weigh slot count, I/O capacity and memory configuration. The table below sets this model against typical alternatives in the same family.
| Feature | this controller | Higher-tier 90-70 CPUs |
|---|---|---|
| Slot width | Single slot | Often multi-slot |
| Maximum I/O | 512 (any mix) | Larger capacity |
| Analog I/O | 8000 | Varies by model |
| Microprocessor | 80C186 | Faster variants |
| Best fit | Compact racks, standard control | Large, high-point-count systems |
For many retrofits, this controller offers the right balance of capacity and rack space. Confirm your required I/O count and memory needs before ordering.
Sourcing Checklist Before You Order
Verify the exact part number and any revision notes on your existing CPU. Confirm whether your application needs the full 512-point I/O capacity or the 8000 analog I/O support. Decide between surplus and refurbished condition based on your maintenance criticality. Autronexa can cross-reference your rack configuration and confirm compatibility with your existing I/O and option modules. Share your part number with Autronexa and we will confirm verified condition and current availability.
Frequently asked questions
Is the IC697CPU731 a genuine GE Fanuc unit or a clone?
Autronexa verifies every IC697CPU731 against OEM datasheet markings and part-number cross-reference before it is listed. Units are genuine surplus or professionally refurbished, not grey-market copies.
What condition will the IC697CPU731 arrive in?
The IC697CPU731 is supplied as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus condition may also be available on request.
How fast can you ship the IC697CPU731?
Lead time for the IC697CPU731 depends on current stock and condition. Contact Autronexa with your part number for verified condition and current availability.
Does the IC697CPU731 work with my existing Series 90-70 I/O modules?
The IC697CPU731 communicates with connected I/O and smart option modules through the PLC backplane. Confirm your specific module mix with Autronexa before ordering.
Related & compatible parts
Schneider Electric
BMXP341000H
Genuine surplus BMXP341000H processor module for Modicon M340 — verified condition, clear lead times, and practical sourcing support…
Schneider Electric
ATV71HU40N4
Genuine surplus Schneider ATV71HU40N4 4 kW drive — verified condition, faster lead time than OEM, and practical sourcing…
Schneider Electric
BMEH582040C
Genuine surplus BMEH582040C redundant processor module for Modicon M580 — verified condition, tested, and ready to ship.
Schneider Electric
PC-E984-785
Genuine surplus Schneider Electric PC-E984-785 Modicon compact controller — verified condition, Modbus connectivity, ready to ship.
News & guides for General Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…