Technical specifications
| Product Type | Replacement gasket |
|---|---|
| Product Line | Quickpanel |
| Compatibility | 15-inch Quickpanel+ Units |
| Weight | 3.00 lbs (1.36 kg) |
| Enclosure | Metal Enclosure |
| Required Enclosure Protection Rating | IP 65 |
| Repeated Insertion and Removal | Not Recommended |
| Input Voltage | 12/24 Volts DC |
| Power Consumption Rating | 30 Watts |
Description
The IC755ACC15GAS is a General Electric replacement gasket designed for 15-inch Quickpanel+ units. It restores the seal that comes pre-installed on these industrial touchscreen computers, and Autronexa supplies it as a genuine surplus component with verified condition. Maintenance teams turn to this gasket when the original seal is damaged and the panel needs to keep its IP 65 enclosure protection. Because the gasket is a field-replaceable item, keeping a verified spare on hand avoids extended downtime while a replacement is sourced.
What this unit Gasket Does in a Quickpanel+ Installation
The gasket sits between the Quickpanel+ terminal and its metal enclosure, helping maintain the IP 65 protection rating required for the installation. General Electric specifies a metal enclosure for these 15-inch units, and the gasket is the sealing element that supports that environmental protection. The part is not a connector or a display component; it is a consumable seal. Repeated insertion and removal of the terminal is not recommended, because each cycle can stress the gasket. When the seal is compromised, fitting a fresh gasket like this unit restores the intended protection. The 15-inch Quickpanel+ units themselves weigh approximately 9.83 pounds and measure 15.71 x 12.72 x 2.76 inches, so the gasket is matched to that specific chassis size. The terminals run on 12/24 Volts DC with a maximum power consumption rating of 30 Watts, and they are based on a 1 Gigahertz ARM Cortex A8 microprocessor running Windows Embedded Compact 7. None of those electronics are affected by the gasket, but the seal is what keeps the enclosure rating intact around them.

Why Genuine Surplus Makes Sense for This Gasket
A replacement gasket is a small part with a large operational role. If a 15-inch Quickpanel+ unit loses its seal, the IP 65 rating is no longer assured, and the terminal becomes vulnerable to the dust and moisture the enclosure was designed to exclude. Sourcing a genuine General Electric gasket avoids the fit and material uncertainty of an unbranded alternative. Autronexa specializes in genuine surplus and refurbished automation components, so this this unit is supplied as a verified surplus item rather than a new-from-OEM purchase. That approach helps when OEM lead times stretch and a maintenance window cannot wait. The gasket is lightweight at 3.00 lbs (1.36 kg), which keeps shipping practical. For engineers maintaining Quickpanel+ fleets, holding a verified spare gasket is a straightforward way to protect the enclosure rating without overstocking.

Sourcing Checklist Before You Order
Before purchasing, confirm that your unit is a 15-inch Quickpanel+ model, because this unit is specified for that display size. Check the condition of the existing gasket and the enclosure surface; a damaged or distorted metal enclosure can prevent a proper seal even with a new gasket. Review the installation environment as well, since General Electric recommends well-ventilated locations free from rain, dust, corrosive gases, and direct sunlight. Avoid repeated removal and insertion of the terminal after fitting the gasket, as this is not recommended and can shorten seal life. When you contact Autronexa, share your part number and confirm the verified condition and current availability. Our team can also help you cross-check related Quickpanel+ accessories and answer practical questions about fitting. Genuine parts, verified, with surplus and refurbished stock ready to ship.
Frequently asked questions
Is the IC755ACC15GAS a genuine General Electric part or a clone?
The IC755ACC15GAS is supplied by Autronexa as a genuine surplus General Electric component. Each unit is checked against OEM datasheet markings and part-number references before it is offered, so you can fit it with confidence.
What condition will the IC755ACC15GAS gasket arrive in?
Autronexa supplies the IC755ACC15GAS as a verified surplus item. Contact us with your part number to confirm the verified condition and current availability before ordering.
How fast can Autronexa ship the IC755ACC15GAS?
Lead time for the IC755ACC15GAS depends on current stock. Share your part number with Autronexa and we will confirm verified condition and current availability, including shipping timing.
Which Quickpanel+ units does the IC755ACC15GAS fit?
The IC755ACC15GAS is a replacement gasket for 15-inch Quickpanel+ units. It is not specified for other display sizes, so confirm your terminal is the 15-inch model before ordering.
Related & compatible parts
ABB
DI880
Genuine ABB DI880 16-channel digital input module — surplus and refurbished, verified condition, ready to ship.
Schneider Electric
170ADM54080
Genuine surplus Schneider Electric 170ADM54080 Modbus I/O base for Modicon Momentum — 6 discrete inputs, 3 outputs, verified…
Schneider Electric
TM218LDA40DR2HN
Genuine surplus Schneider Modicon M218 controller, 40 I/O with relay outputs and Ethernet — verified condition, ready to…
Bently Nevada · 31000 / 32000 Series
31000-28-10-00-020-03-02
Bently Nevada 31000-28-10-00-020-03-02 Proximity Probe Housing. Fittings: Two plugs, one 3/4-14 NPT fitting; O-Ring Material: Neoprene®.
News & guides for General Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…