Schneider Electric Power Supplies
Schneider Electric 140CPS11420C
Power Supply Module
Genuine surplus Schneider 140CPS11420C Modicon Quantum power supply, 115/230 VAC to 5.1 VDC at 11 A — verified condition and clear lead times.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Product Line | Modicon Quantum |
|---|---|
| Input Voltage | 115/230 VAC |
| Output Voltage | 5.1 VDC |
| Output Current | 11 A |
| Input Current | 1300 mA at 115 V, 750 mA at 230 V |
| Inrush Current | 38 A at 115 V, 19 A at 230 V |
| Rated Power | 130 VA |
| Relay Contact | Normally closed, 220 VAC 6 A / 30 VDC 5 A |
| Operating Temperature Range | 0 to 60 °C |
| Dimensions / Weight | 40 mm W x 250 mm H x 104 mm D; 1.5 kg |
Description
When a Modicon Quantum rack loses its 5.1 VDC rail, every module downstream stops communicating. The Schneider Electric 140CPS11420C power supply module restores that rail: 115/230 VAC input, 5.1 VDC output at up to 11 A, rated 130 VA. Autronexa supplies this unit as verified genuine surplus or refurbished stock, giving maintenance teams a tested alternative to long OEM lead times.
What This Quantum Power Supply Does in the Rack
The 140CPS11420C sits in the Modicon Quantum product line and converts plant AC into the regulated DC the backplane needs. Its dual input range lets the same module run on 115 V or 230 V mains, so a single spare covers both supply standards in a mixed plant. Input current is 1300 mA at 115 V and 750 mA at 230 V; inrush current reaches 38 A and 19 A respectively at startup. The normally closed relay contact is rated 220 VAC, 6 A or 30 VDC, 5 A, giving you a switching path for status or alarm wiring. The module measures 40 mm wide, 250 mm high and 104 mm deep and weighs 1.5 kg, so it fits standard Quantum rack space without reworking the enclosure.

Why Genuine Surplus Beats Waiting on a New Build
Power supplies are among the first Quantum parts to fail and among the hardest to justify buying new at list price when a line is down. A genuine surplus or refurbished unit solves both problems: it is verified against OEM datasheet markings and functionally tested by our sourcing team, and it ships from stock rather than a production queue. For this model the practical checks are the dual input configuration and the 11 A output rating — a lower-rated substitute will not carry the same load. Autronexa stocks surplus and refurbished, ready to ship, and every unit is inspected before dispatch. Please verify current lifecycle status and availability with Autronexa before ordering.

Sourcing Checklist Before You Buy
Confirm three things before committing to any unit. First, the exact part number and revision — Quantum power supplies are not interchangeable across ratings. Second, the input setting your panel uses: 115 V draws 1300 mA and 230 V draws 750 mA, and the inrush figures differ too, so match the unit to your supply. Third, condition: ask whether the unit is surplus or refurbished and request the test record. The operating range of 0 to 60 °C suits most control cabinets, but check ambient temperature at the mounting slot. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 140CPS11420C, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished modules, not grey-market copies.
What condition will the power supply arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — ask for the condition and test record for the specific unit.
How fast can you ship the 140CPS11420C?
Lead time depends on current stock. Contact Autronexa for current lead time and availability; surplus and refurbished units typically ship faster than a new OEM build.
Does this module work on both 115 V and 230 V supplies?
Yes. The module accepts 115/230 VAC input, drawing 1300 mA at 115 V and 750 mA at 230 V, with inrush current of 38 A and 19 A respectively. Confirm your panel's supply setting before installation.
Is the 140CPS11420C still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status, and we can confirm current availability of surplus or refurbished units.
Related & compatible parts
Schneider Electric
140NOE77110C
Genuine surplus Schneider Electric 140NOE77110C Ethernet module for Modicon Quantum — Modbus TCP/IP, verified condition, ready to ship.
Schneider Electric
BMENOC0321C
Genuine surplus Schneider Electric BMENOC0321C communication module for Modicon M580 — verified condition, faster than OEM lead times.
Schneider Electric
TM3DI32K
Genuine surplus Schneider TM3DI32K discrete input module — 32 sinking/sourcing inputs, 24V DC, HE10 connector. Verified condition, ready…
Schneider Electric
BMXEHC0800
Genuine surplus Schneider Electric BMXEHC0800 8-channel high-speed counter module — verified, tested, and ready to ship from Autronexa.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…