Schneider Electric Power Supplies
Schneider Electric 140CPS12420C
Power supply module
Genuine surplus Schneider Electric 140CPS12420C power supply for Modicon Quantum — verified condition, faster lead time than OEM.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Input Voltage | 115 V to 230 V |
|---|---|
| Input Current | 1100 mA |
| Inrush Current | 19/38 A |
| Rated Power | 130 VA |
| Output Voltage | 5.1 V DC |
| Associated Fuse Rating | 2 A, slow-blow |
| Alarm Output | 1 NC 6 A 220 V power supply fault |
| Local Signalling | 1 LED (green) for PWR OK |
| Output Overvoltage Protection | Internal |
| Weight | 0.65 kg |
Description
When a Modicon Quantum rack loses its 5.1 V DC supply, every I/O module on that backplane goes dark. The Schneider Electric 140CPS12420C power supply module restores that rail, accepting 115 V to 230 V input and delivering a rated 130 VA. For maintenance teams running legacy Quantum systems, a verified surplus or refurbished unit is often the fastest path back to production — genuine parts, verified before dispatch.
What This Power Supply Does in a Quantum Rack
The 140CPS12420C is a single-slot power supply module built for the Modicon Quantum platform. It converts a 115 V to 230 V AC input into a regulated 5.1 V DC output, which is the logic rail that Quantum processors and I/O modules draw from. Input current is rated at 1100 mA, with an inrush current of 19/38 A at startup — a figure that matters when you are sizing upstream breakers and confirming the circuit can absorb the initial surge without nuisance trips.
Two diagnostic features make this module practical to commission. A green PWR OK LED gives a local indication that the output rail is healthy, so a technician can confirm power at the rack without a meter. A normally closed alarm contact, rated 6 A at 220 V, can be wired to a panel or PLC input to report a power supply fault remotely. Internal output overvoltage protection is built in, guarding downstream modules against spikes on the 5.1 V rail. The associated fuse rating is 2 A, slow-blow, which tolerates brief peak currents during startup.

Why Genuine Surplus Fits This Module
Schneider Electric has moved its control portfolio forward over the years, and Quantum installations remain in service across process and utility plants. When a supply module fails, waiting on an OEM lead time is rarely acceptable — the rack is down. Autronexa stocks surplus and refurbished Quantum components, and each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before it ships. That means the 5.1 V DC output, the PWR OK LED and the alarm contact are checked, not assumed.
Buying surplus here is not a gamble on condition. You get a genuine Schneider Electric module with the ratings above, at a cost below OEM list, with a clear lead time confirmed before you commit. For a 0.65 kg module that slots directly into an existing Quantum backplane, that is a practical swap rather than a re-engineering project.

Sourcing Checklist Before You Order
Confirm three things before you request a unit. First, verify the part number matches your existing module exactly — unit is the specific Quantum power supply variant, and mixing it with a different supply in the same rack can leave modules under-fed. Second, confirm the input voltage available at your panel falls within the 115 V to 230 V range. Third, decide whether you need a surplus unit or a refurbished one, and ask for the condition grading in writing.
Autronexa can cross-reference the EAN and part number against OEM markings so you know the module is authentic. Please verify current lifecycle status and availability with Autronexa before ordering, since Quantum support varies by region. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 140CPS12420C, or a clone?
Autronexa verifies every unit against OEM datasheet markings and cross-references the part number and EAN before it enters stock. The module you receive is a genuine Schneider Electric power supply, not a copy.
What condition will the 140CPS12420C arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — ask for the condition grading in writing when you request a quote.
How fast can Autronexa ship this power supply module?
Lead time depends on current stock. Contact Autronexa with your part number and we will confirm verified condition and current availability, including the expected ship date, before you place the order.
Does the 140CPS12420C work in any Modicon Quantum rack?
It is built for the Modicon Quantum platform and delivers 5.1 V DC at a rated 130 VA. Confirm your rack's power budget and slot assignment against your existing configuration before ordering.
Is the 140CPS12420C still supported by Schneider Electric?
Lifecycle status for Quantum components varies by region. Contact Autronexa to verify OEM support status and availability for this specific part number before you plan a replacement.
Related & compatible parts
Schneider Electric
ATV71HU15N4
Genuine surplus Schneider Electric ATV71HU15N4 drive — 1.5 kW, 3-phase, vector control. Verified condition and current availability from…
Schneider Electric
BMXP342020
Genuine surplus Schneider BMXP342020 processor module for Modicon M340 — verified condition, faster than OEM lead time.
Schneider Electric
170ADM37012
Genuine surplus Schneider 170ADM37012 mixed I/O module — 16 DI, 8 DO, 4 AI, 2 AO. Verified condition,…
Schneider Electric
BMXP342000
Genuine surplus Schneider Electric BMXP342000 processor module for Modicon M340 — verified condition, practical pricing, and faster sourcing…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…