Technical specifications
| Number of Counters | 2 |
|---|---|
| Counter Input Resolution | 24 bits + sign |
| Counting Frequency | 10 kHz single ended; 200 kHz differential |
| Discrete Inputs / Outputs | 6 inputs / 4 outputs |
| Discrete Output Voltage | 24 V DC |
| Input Overvoltage Protection | 45 V for 10 s |
| Current Consumption | 280 mA at 24 V DC |
| Operating Temperature | 32…140 °F (0…60 °C) |
| Certifications | UL, CSA |
| Net Weight | 0.46 lb (0.21 kg) |
Description
When a high-speed counting axis stalls on a running Modicon Momentum line, every hour of downtime compounds. The Schneider Electric 170AEC92000 high-speed counter module base gives you two 24-bit counters with 200 kHz differential counting, and sourcing a genuine surplus unit through Autronexa gets you back online faster than waiting on OEM lead times.
What This Counter Base Does in a Momentum System
The 170AEC92000 is the base-level counter module for Schneider’s Modicon Momentum platform. It carries two counter channels, each configurable for incremental up/down, quadrature, or absolute SSI counting with four sub-modes. Counting resolution reaches 24 bits plus sign, so the module tracks position or flow pulses without rollover errors on long moves. The base provides six discrete inputs arranged in two groups of three, and four discrete outputs in two groups of two. Inputs accept 3…30 V DC single-ended or 5 V differential signals; outputs switch 24 V DC positive logic at 0.5 A per point, 1 A per counter, and 2 A per module. Response time is under 0.1 ms on the output circuit and 3 ms on the input circuit — fast enough for registration and cut-to-length work where the counter must react before the next pulse arrives.

Technical Specs That Matter on the Floor
Three values drive most selection decisions. First, counting frequency: 10 kHz single-ended and 200 kHz differential. If your encoder runs differential 5 V lines, the module keeps pace with high-resolution feedback; single-ended 24 V signals top out an order of magnitude lower. Second, input overvoltage protection: 45 V for 10 seconds. That tolerance absorbs the inductive spikes common on 24 V DC input wiring without latching the module into a fault. Third, current thresholds: state 1 guaranteed at ≥ 2.5 mA and state 0 guaranteed at ≤ 1.2 mA, with voltage thresholds of ≥ 11 V for ON and ≤ 5 V for OFF. These margins define how clean your field wiring must be — marginal signals that sit between 5 V and 11 V will read unpredictably. The module also carries TC (Tropicalization Protection) and UL/CSA certification, and operates from 32…140 °F (0…60 °C) at up to 95 % relative humidity without condensation.
Why Genuine Surplus Fits This Module
Schneider’s Modicon Momentum platform remains widely installed, but OEM lead times on individual base modules can stretch while a line sits idle. Autronexa stocks surplus and refurbished unit units that our sourcing team tests against OEM datasheet specifications and functionally verifies before shipment. You get a genuine part with documented condition, not a grey-market pull of unknown history. The module draws 280 mA at 24 V DC and weighs roughly 0.46 lb (0.21 kg), so it ships economically. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 170AEC92000, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished modules, not copies.
What condition will the 170AEC92000 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade.
How fast can you ship the 170AEC92000?
Lead time depends on current stock. Contact Autronexa for current lead time and availability on this counter module base.
Does this module work with my existing Modicon Momentum adapter?
Counter configuration is set via the comm adapter, and the base uses two connectors for removable terminal blocks. Confirm your adapter model with Autronexa before ordering.
Is the 170AEC92000 still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability.
Related & compatible parts
Schneider Electric
BMEP582020H
Genuine surplus BMEP582020H M580 processor for severe environments — verified condition, faster than OEM lead times.
Schneider Electric
ATV71HU75N4
Genuine surplus Schneider ATV71HU75N4 Altivar 71 drive, 7.5 kW, 480 V three-phase, IP20, with integrated EMC filter and…
Schneider Electric
140ARI03010C
Genuine surplus Schneider Electric 140ARI03010C analogue input module — 8 differential inputs, 13-bit resolution, verified condition and ready…
Schneider Electric
170LNT71000
Genuine surplus Schneider Electric 170LNT71000 DeviceNet adapter for Modicon Momentum — verified condition, faster than OEM lead times.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…