Schneider Electric Drives & Inverters

Schneider Electric ATV310H075N4S

Variable speed drive

Manufacturer: Schneider Electric Part Number: ATV310H075N4S

Genuine surplus Schneider ATV310H075N4S drive: 0.75 kW, 380–460 V three-phase, sensorless vector control, verified condition and clear lead times.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Rated motor power 0.75 kW (1 HP)
Supply voltage 380...460 V AC, 50/60 Hz, three-phase
Maximum continuous output current (In) 2.3 A at 380 V
Motor compatibility Three-phase synchronous motors (SPM and IPM)
Integrated EMC filter None (external filter required for IEC/EN 61800-3)
Built-in communication 1 RJ45, 2-wire RS-485, Modbus RTU
Operating temperature -10...+55 °C without derating
Protection rating IP20 (IP4X/IP40 top with vent cover)
Dimensions (H×W×D) 143 × 72 × 140 mm
Weight 0.8 kg

Description

When a 0.75 kW three-phase synchronous motor on a pump or fan skid needs precise speed control but the OEM lead time stretches weeks, the Schneider Electric ATV310H075N4S variable speed drive becomes the practical answer. Autronexa supplies this Easy Altivar 310 unit as genuine surplus or professionally refurbished stock — verified against OEM datasheet markings, not a grey-market clone.

What This Drive Does in a Synchronous-Motor Installation

The ATV310H075N4S is a frame-size 1 AC frequency inverter rated 0.75 kW (1 HP) with a 380…460 V three-phase supply. Unlike the asynchronous-only N4E variants, this N4S model adds control of three-phase synchronous motors (SPM and IPM), per the user manual EAV94277 p.69. It offers 2-point V/f, sensorless vector control with an internal speed loop, and a U2/f pump law for variable-torque fan and pump loads. A 4-digit keypad with navigation and RUN/STOP buttons handles local setup. The drive has no integrated EMC filter — an external EMC filter is required to meet IEC/EN 61800-3 — so plan your panel layout accordingly.

Figure 1: Front view of the Schneider Electric ATV310H075N4S Variable speed drive showing its physical design and enclosure.

Technical Specs That Affect Your Panel Design

At 380 V the maximum continuous output current is 2.3 A at the nominal 4 kHz switching frequency, with 3.5 A transient for 60 s. Maximum input current is 3.5 A at 380 V and 3.1 A at 460 V; apparent power is 2.5 kVA at 460 V. The switching frequency adjusts from 2…12 kHz, but derate nominal current 10% for continuous 8 kHz and 20% for 12 kHz. Starting torque reaches 150% of rated motor torque at 3 Hz, and the integrated braking chopper terminals (PA/+ and PB) deliver more than 70% braking torque without an external resistor. The drive dissipates 34.1 W at In on 380 V, measures 143 × 72 × 140 mm with heatsink, and weighs 0.8 kg. Built-in communication is one RJ45 port for 2-wire RS-485 Modbus RTU; there is no plug-in fieldbus slot.

Figure 2: Technical layout and connection details for the Schneider Electric ATV310H075N4S Variable speed drive.

Why Genuine Surplus Fits This Model

Autronexa stocks surplus and refurbished Easy Altivar 310 units because the line remains active — official product pages were verified as of 2026-10 — yet OEM channel lead times can still stall a maintenance window. Each refurbished drive is tested against OEM datasheet specifications and functionally verified by our sourcing team before it ships. The fan is the only wearing part and is tool-free to replace, which makes a verified used unit a low-risk choice for spare-holding or immediate replacement. You get genuine parts, verified, at a fraction of new-list pricing, with practical lead times instead of indefinite backorder dates. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: ATV310H075N4S-datasheet.pdf

Frequently asked questions

Is this ATV310H075N4S a genuine Schneider Electric drive or a clone?

Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before listing. This is genuine surplus or refurbished Schneider Electric stock, not a grey-market copy.

What condition will the drive arrive in?

Our default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade confirmed before ordering.

How fast can Autronexa ship the ATV310H075N4S?

Lead time depends on current stock at the time of your request. Contact Autronexa with your part number for verified condition and current availability; we confirm ship dates before you commit.

Does this drive work with synchronous motors?

Yes. The N4S variant adds three-phase synchronous motor control (SPM and IPM) to the standard V/f and sensorless vector modes, per the user manual EAV94277 p.69.

Is the Easy Altivar 310 line still supported by Schneider Electric?

Official product pages for the Easy Altivar 310 line were active as of 2026-10. Please verify current lifecycle status and availability with Autronexa before ordering.

Related & compatible parts

Schneider Electric

BMXP342010

Genuine surplus Schneider Electric BMXP342010 Modicon M340 CPU module — verified condition, tested, and ready to ship from…

In Stock

Schneider Electric

ATV930C16N4

Genuine surplus Schneider ATV930C16N4 Altivar 930 drive — 160 kW ND, dual-rated, STO safety, verified and ready to…

In Stock

Schneider Electric

TSXAEY800

Genuine surplus Schneider TSXAEY800 analog input module, verified and ready to ship for TSX Micro PLC systems.

In Stock

Schneider Electric

170XTS04200

Genuine surplus Schneider 170XTS04200 shunt plug for Modicon Momentum — verified condition, ready to ship from Autronexa.

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: ATV310H075N4S

We reply within one business day.

ATV310H075N4S Quote reply within 1 business day