Schneider Electric Communication Modules
Schneider Electric 140NOE77111C
Ethernet module
Genuine surplus Schneider 140NOE77111C Ethernet module for Modicon Quantum — verified condition, Modbus TCP/IP, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Product Line | Modicon Quantum |
|---|---|
| Communication Port Protocol | Ethernet Modbus TCP/IP |
| Transmission Rate | 10/100 Mbit/s |
| Web Server Class | C30 |
| Current Consumption | 750 mA 5 V DC |
| Supply | Via the power supply of the rack |
| Protection Class | IP20 |
| Ambient Temperature | 0 to 60 °C |
| Humidity | 95 % without condensation |
| Certifications | UL 508, cUL |
Description
When a Modicon Quantum rack loses its Ethernet link, every scan cycle that depends on that data path stalls. The 140NOE77111C from Schneider Electric restores Ethernet Modbus TCP/IP communication at 10/100 Mbit/s, and Autronexa supplies it as verified genuine surplus — tested against OEM datasheet specifications and functionally verified before dispatch.
What This Module Does in a Quantum Rack
The 140NOE77111C is a standard-format Ethernet communication module for the Modicon Quantum product line. It carries the Transparent Ready concept and a Class C30 web server classification, which means the module can serve diagnostic and status pages over the network in addition to handling Modbus TCP/IP traffic. For maintenance engineers, that web server is often the first place to look when a controller stops responding: you can check link state and module health without pulling the rack apart.
The module draws 750 mA at 5 V DC and takes its supply directly from the rack power supply, so there is no separate feed to wire or fuse. That single-rail arrangement simplifies swap-outs — one less connection to verify during a replacement. The IP20 protection class suits it to cabinet-mounted installations, and the 0 to 60 °C ambient range with 95 % humidity tolerance without condensation covers typical control-room and enclosure conditions.

Why Surplus Makes Sense for This Part
Quantum installations are long-lived, and Ethernet modules are among the first components pulled when a network segment is reworked or a rack is decommissioned. That keeps genuine units circulating in the surplus channel. Autronexa sources these modules, verifies markings and part-number cross-reference against the OEM datasheet, and functionally tests each unit before it ships. You get a verified module rather than an untested pull, and lead times are typically shorter than waiting on a factory order for an older platform. The CE marking and UL 508 / cUL certifications on the original unit remain the reference point for what the module was built to — we do not re-certify, we verify that the unit matches its original specification.

Sourcing Checklist Before You Order
Confirm the rack slot and backplane position where the module will sit, and check that your existing Quantum CPU firmware expects this communication module rather than a different Ethernet variant in the 140 series. Verify the revision level on your current unit against the replacement — mixed revisions in one rack can complicate diagnostics. Decide whether you need a tested surplus unit or a refurbished one; both are available through Autronexa, and condition is stated on the quote. If your application relies on the web server pages, confirm the Class C30 classification matches what your monitoring tools expect. Please verify current lifecycle status and availability with Autronexa before ordering, since Quantum platform support evolves. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 140NOE77111C, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. The module you receive is a genuine Schneider Electric unit, not a copy.
What condition will the module arrive in?
Units ship as refurbished by default — tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus condition is also available; the exact condition is confirmed on your quote.
How fast can you ship the 140NOE77111C?
Contact Autronexa for current lead time. Stock levels on Quantum modules change quickly, and we confirm availability before accepting an order.
Does this module work with my existing Modicon Quantum rack?
It is a standard-format module for the Modicon Quantum line, powered from the rack supply at 750 mA 5 V DC. Confirm your CPU firmware and slot assignment with our team before ordering.
Is the 140NOE77111C still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before you commit to a replacement plan.
Related & compatible parts
Schneider Electric
BMENOR2200
Genuine surplus Schneider Electric BMENOR2200 RIO head module for Modicon M580 — verified condition, faster lead time than…
Schneider Electric
BMXDDI6402K
Genuine surplus Schneider Electric BMXDDI6402K Modicon X80 64-channel input module — verified, tested, and ready to ship from…
Schneider Electric
140NOM21200
Genuine surplus Schneider 140NOM21200 DIO head-end adaptor for Modicon Quantum — verified, tested, and ready to ship.
Schneider Electric
TSXPSY1610
Genuine surplus Schneider Electric TSXPSY1610 power supply for Modicon — verified condition, fast lead time, practical sourcing support.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…