Schneider Electric I/O & Function Modules
Schneider Electric TSXASZ401
Analog Output Module
Genuine surplus Schneider Electric TSXASZ401 analog output module — 4 channels, 400 µs response, verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Number of Channels | 4 |
|---|---|
| Output Type | 0...10 V, +/- 10 V |
| Response Time | 400 µs |
| Analog/Digital Conversion | 11 bits (0...10 V), 11 bits (+/- 10 V) |
| Output Load | >= 2 Ohm |
| Protection Type | Short-circuit protection |
| Isolation Voltage | 1000 V AC |
| Current Consumption | 90 mA |
| Temperature Drift | 0.096%/10 °C |
Description
When an analog output channel drops out on a running TSX Micro PLC, every minute of unplanned downtime adds cost. The Schneider Electric TSXASZ401 is a four-channel analog output module for the Modicon TSX Micro automation platform, and Autronexa supplies it as genuine surplus — verified against OEM markings before it ships.
What This Module Does in a TSX Micro Rack
The TSXASZ401 slots into the TSX Micro PLCs series and converts controller commands into 0…10 V or +/- 10 V analog signals for actuators, drives, and positioners. Its 400 µs response time suits control loops that need prompt signal processing, and the 11-bit conversion (11 bits 0…10 V, 11 bits + sign +/- 10 V) gives the resolution needed for fine setpoint changes. Short-circuit protection and 1000 V AC isolation help protect the module and downstream wiring during faults. Current consumption is 90 mA, keeping the load on the rack supply modest. For maintenance teams, the practical point is simple: this is a drop-in replacement for a failed output card in an existing TSX Micro installation, with the same channel count and output ranges the application was built around.

Why Genuine Surplus Fits This Output Card
TSX Micro systems are long-established in the field, and OEM lead times for legacy cards can stretch while a line sits idle. Autronexa stocks surplus and refurbished units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. That means you get the four-channel configuration, the 0…10 V and +/- 10 V ranges, and the >= 2 Ohm output load rating this module was designed for — not a substitute with different characteristics. Refurbished units are checked for channel integrity and isolation before dispatch, and we confirm condition and current availability before you commit. For a maintenance engineer, that shortens the path from fault finding to a working output channel without paying full OEM list price.

Sourcing Checklist Before You Order
Confirm the exact model and revision against the failed card, and note whether your application uses the 0…10 V or +/- 10 V range so the replacement matches the existing wiring. Decide between surplus and refurbished condition based on how critical the loop is and how soon you need the part. Check that the module is RoHS compliant as your site records require. Please verify current lifecycle status and availability with Autronexa before ordering, since legacy TSX Micro stock moves quickly. If you are unsure which variant your rack accepts, send us the existing part number and a photo of the label — our sourcing team works with these platforms daily and can confirm the match.
Frequently asked questions
Is this a genuine Schneider Electric TSXASZ401, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. The TSXASZ401 we supply is genuine Schneider Electric, not a copy or grey-market substitute.
What condition will the module arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — confirm the condition you need when you contact us.
How fast can you ship the TSXASZ401?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus and refurbished units are ready to ship once confirmed.
Does this module work with my existing TSX Micro PLC?
The TSXASZ401 is an analog output module for the Modicon TSX Micro automation platform, with four channels and 0...10 V or +/- 10 V output. Confirm your rack and wiring match this configuration before ordering.
Is the TSXASZ401 still supported by Schneider Electric?
Lifecycle status is not stated in our data. Please verify current lifecycle status and availability with Autronexa before ordering, as legacy TSX Micro stock changes frequently.
Related & compatible parts
Schneider Electric
170AAO92100
Genuine surplus Schneider Electric 170AAO92100 analog output base module — 4 outputs, 16-bit signed, verified condition and ready…
Schneider Electric
ATV930U55N4Z
Genuine surplus Schneider ATV930U55N4Z Altivar 930 drive, 5.5 kW ND, dual-rated, verified condition and ready to ship.
Schneider Electric
ATV320U11N4W
Genuine surplus Schneider ATV320U11N4W: 1.1 kW, IP66, integrated C2 EMC filter. Verified condition, fast lead times.
Schneider Electric
ABFM04S200
The Schneider Electric ABFM04S200 cable connector is built for reliable analog output connections within the Modicon Quantum series.…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…