Technical specifications
| Number of Inputs | 32 |
|---|---|
| Input Voltage | 24 V DC positive |
| Input Current | 3.5 mA |
| Response Time | ≤ 7 ms |
| Sensor Supply | 19…30 V |
| Electrical Connection | HE-10 connector |
| Mounting | DIN rail |
| IP Degree of Protection | IP20 |
| Product Certifications | CE, UL 508, CSA C22.2 |
Description
The Schneider Electric TSXDEY32D2K is a 32-channel digital input module for TSX Micro PLC systems, built to bring large banks of 24 V DC field signals into a control cabinet. Maintenance and procurement teams choose genuine surplus or refurbished units when OEM lead times stretch and a panel needs to return to service. Autronexa verifies each module against OEM datasheet markings before it ships.
What This Module Does in a TSX Micro Rack
The module reads 32 discrete inputs at 24 V DC positive, with a sensor supply range of 19…30 V. Each channel draws 3.5 mA, so a fully loaded module presents a predictable load to the sensor supply. The input thresholds are clearly defined: state 1 is guaranteed at ≥ 11 V and ≥ 3 mA, while state 0 is guaranteed at ≤ 5 V and ≤ 1.5 mA. That margin matters in panels where cable runs pick up noise — a channel will not chatter between states when the signal sits well inside either band.
Response time is ≤ 7 ms, which suits general-purpose discrete sensing rather than high-speed registration. The module connects through a HE-10 connector and mounts on DIN rail in a standard module format. Isolation resistance is specified at < 10 MOhm at 500 V DC, and the unit carries CE marking along with UL 508 and CSA C22.2 standards. Operating altitude is rated to 2000 m, and the IP20 protection suits cabinet installation.

Why Genuine Surplus Fits This Input Module
The TSX Micro and Premium families are mature platforms, and many plants still run them in packaging, material handling and utility panels. When a 32-channel input card fails, the replacement decision is usually driven by how fast a verified unit can be on site, not by a specification review. Autronexa stocks genuine surplus and refurbished automation components, and each module is functionally verified by our sourcing team before dispatch. That means the thresholds and channel count you depend on are checked, not assumed.
Refurbished units are tested against OEM datasheet specifications, and surplus stock is inspected for physical and electrical condition. Because we specialise in Allen-Bradley, Bently Nevada, Siemens and Schneider Electric among others, our sourcing team can confirm revision details and connector compatibility with your existing rack. Please verify current lifecycle status and availability with Autronexa before ordering, since platform support can change.

Sourcing Checklist Before You Order
Confirm the exact part number and any revision suffix on the failed module, because TSX input cards share a common form factor but differ in channel count and voltage. Check whether your panel uses the HE-10 connector and that the sensor supply stays within 19…30 V. Decide between surplus and refurbished condition based on whether the unit is going into a critical line or a spares shelf. Autronexa provides verified condition notes and clear lead times with every quote, so you can plan the swap without guesswork. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric TSXDEY32D2K or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it is listed. The module you receive is genuine Schneider Electric stock, not a copy.
What condition will the TSXDEY32D2K arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available and are inspected for physical and electrical condition.
How fast can Autronexa ship this input module?
Lead time depends on current stock at the time of your request. Contact Autronexa with your part number for verified condition and current availability, and we will confirm the shipping date.
Does the TSXDEY32D2K work with my existing TSX Micro rack?
The module is designed for TSX Micro PLC systems and uses a HE-10 connector with DIN rail mounting. Confirm your rack series and connector type with our sourcing team before ordering.
Is the TSXDEY32D2K still supported by Schneider Electric?
Lifecycle status can change, so please verify current lifecycle status and availability with Autronexa before ordering. Our team can check OEM support status for you.
Related & compatible parts
Schneider Electric
ATV930U75N4Z
Genuine surplus ATV930U75N4Z variable speed drive from Schneider Electric — verified condition, faster lead time than OEM.
Schneider Electric
TSXCTY2C
Genuine surplus Schneider TSXCTY2C counter module: 2 channels, 1 MHz, 24 V sink inputs. Verified condition, ready to…
Schneider Electric
140AIO33000
Genuine surplus Schneider Electric 140AIO33000 intrinsically safe analog output module — 8 outputs, verified condition, ready to ship.
Schneider Electric
170XTS00900
Genuine surplus Schneider Electric 170XTS00900 Interbus terminal connector kit — verified condition, practical sourcing support, ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…