Schneider Electric I/O & Function Modules
Schneider Electric TSXDSY16R5
Output Module Modicon Premium 16-point Relay
Genuine surplus Schneider Electric TSXDSY16R5 16-point relay output module for Modicon Premium — verified condition, practical sourcing support.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Channels | 16 points (2 groups × 8) |
|---|---|
| Signal type | Relay output (NO, electromechanical) |
| Voltage range | 24 V DC to 250 V AC |
| Output current | 3 A per channel (conventional thermal current), 5 A max at 250 V AC / 30 V DC |
| Isolation | Channel-to-bus: 1500 V AC dielectric; isolation resistance >10 MΩ @ 500 V |
| Response time | <8 ms (activation), <10 ms (deactivation) |
| Bus current | 80 mA @ 5 V DC |
| Power consumption | 0.25 W + (0.2 W × number of outputs at state 1) |
| Protection rating | IP20 |
| Dimensions (H×W×D) | 140 × 35 × 80 mm |
Description
The Schneider Electric TSXDSY16R5 is a 16-point relay output module for the Modicon Premium platform, built for maintenance and procurement teams keeping discrete control systems running. Because the model is discontinued, sourcing a genuine surplus or professionally refurbished unit — verified against OEM datasheet markings — is often the fastest practical route to restoring output capacity without redesigning the rack.
What This Module Does in a Modicon Premium Rack
The TSXDSY16R5 provides 16 discrete relay outputs arranged as two groups of eight, occupying a single slot in a Modicon Premium rack. Each channel is a normally-open electromechanical relay, so the module can switch loads across a 24 V DC to 250 V AC range — useful where a panel mixes low-voltage signalling with higher-voltage contactor or valve circuits. Per-channel conventional thermal current is 3 A, with 5 A maximum at 250 V AC or 30 V DC. Channel-to-bus isolation is rated 1500 V AC dielectric with isolation resistance above 10 MΩ at 500 V, which matters when field wiring runs near noisy equipment. Activation response is under 8 ms and deactivation under 10 ms. There are no built-in diagnostics: each channel or group needs an external fuse, so plan fuse coordination before commissioning. The module draws 80 mA at 5 V DC from the backplane and is rated IP20, with dimensions of 140 × 35 × 80 mm and a weight of 0.25 kg.

Why Surplus Makes Sense for a Discontinued Output Module
Schneider Electric lists this module as discontinued, last verified in 2026-09. That changes the buying decision: OEM lead time may be unavailable or unpredictable, and a rack that still needs 16 relay outputs cannot wait on a redesign. Autronexa stocks genuine surplus and refurbished automation components, and refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch. For a module like this, the practical checks are the relay contact condition, the backplane connector, and the channel-to-bus isolation — the same points a maintenance engineer would inspect on a pulled unit. Surplus and refurbished stock is ready to ship once condition is confirmed, which shortens the gap between fault finding and a running line.

Buyer Checklist Before You Order
Start with the exact model and series match: this is the Modicon Premium 16-point relay variant, not a transistor or triac output module, and the two are not interchangeable in wiring or load behaviour. Confirm your rack slot budget — the unit needs one slot — and verify that your field loads fall inside the 24 V DC to 250 V AC range and the stated current limits. Because there is no built-in diagnostics, check that external fusing exists per channel or group in your panel. Ask for the condition grade (surplus versus refurbished) and any markings or labels present on the unit. Please verify current lifecycle status and availability with Autronexa before ordering, and contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric TSXDSY16R5, or a clone?
Autronexa verifies units against OEM datasheet markings and part-number cross-reference before listing. The TSXDSY16R5 is supplied as genuine surplus or refurbished stock, not a grey-market copy.
What condition will the module arrive in?
The site default condition is Refurbished: units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa to confirm the specific condition grade of the unit on hand.
How fast can you ship the TSXDSY16R5?
Lead time depends on current stock. Contact Autronexa for current lead time and availability; surplus and refurbished units are ready to ship once condition is confirmed.
Is the TSXDSY16R5 still supported by Schneider Electric?
The model is listed as discontinued, last verified in 2026-09. Contact Autronexa to verify OEM support status and to discuss surplus or refurbished replacement options.
Does this module need external fusing?
Yes. The TSXDSY16R5 has no built-in diagnostics, and an external fuse is required per channel or group. Confirm your panel's fuse coordination before commissioning.
Related & compatible parts
Schneider Electric
ATV320U15N4WS
Genuine surplus Schneider ATV320U15N4WS: 1.5 kW, IP65 wall-mount VSD with disconnect switch and C2 EMC filter. Verified condition,…
Schneider Electric
iC60N 3P C63
Genuine surplus Schneider Electric iC60N 3P C63 miniature circuit breaker — 63A, C-curve, 6 kA, verified condition and…
Schneider Electric · Advantys STB
STBDAO5260
Genuine surplus Schneider STBDAO5260: 2-channel 115V AC isolated digital output module for Advantys STB. Verified condition, ready to…
Schneider Electric
NWBP85002
Genuine surplus NWBP85002 Modbus Plus bridge for Modicon Premium/Quantum — verified condition, faster than OEM lead time.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…