Schneider Electric Circuit Protection
Schneider Electric iC60N 4P C32
Circuit Breaker
Genuine surplus Schneider iC60N 4P C32 miniature circuit breaker — verified 32 A, C-curve, 6 kA, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Poles | 4P |
|---|---|
| Rated current | 32A |
| Trip curve | C (thermal-magnetic, magnetic trip 8×In ±20%) |
| Breaking capacity | 6 kA @ 230/400V (IEC 60898-1) |
| Rated voltage | 400V AC |
| Standard | EN/IEC 60898-1, EN/IEC 60947-2 |
| Operating temperature | -35 to 70 °C |
| Mounting | 35 mm DIN rail |
| Mechanical life | 20,000 cycles |
| Electrical life | 10,000 cycles |
Description
When a four-pole feeder trips and the replacement has to match the existing Acti9 board exactly, the iC60N 4P C32 from Schneider Electric is the part most maintenance teams ask for. Autronexa supplies this 32 A C-curve miniature circuit breaker as verified genuine surplus, so you keep the original device footprint without waiting on a factory order.
Why This Breaker Fits the Four-Pole Feeder Role
The iC60N 4P C32 sits in the Acti9 iC60 family, a range built around DIN-rail distribution boards. Its job is to open all four poles together when a fault occurs, which matters on three-phase feeders where a single-pole trip would leave the circuit partially live. The C trip curve uses thermal-magnetic protection with a magnetic trip at 8×In ±20%, so it tolerates short inrush currents from small motors and transformers without nuisance tripping, while still clearing a genuine short circuit. Rated voltage is 400V AC and breaking capacity is 6 kA at 230/400V under IEC 60898-1, which covers the fault levels found in most final distribution boards. The device measures 85 × 72 × 78.5 mm and weighs 0.5 kg, so it drops into the same 35 mm DIN rail space as the unit it replaces.

The Sourcing Problem: Matching an Active Range Without the Wait
Because the Acti9 range is listed as active and in production, buyers sometimes assume a new unit is the only route. In practice, a spare pulled from verified surplus stock often reaches a site faster than a factory lead time, and it keeps the board on its original specification rather than forcing a substitute. Autronexa holds genuine surplus and refurbished automation components, and each unit is checked against OEM datasheet markings and part-number cross-reference before it is offered. For this breaker, the practical checks are the pole count, the 32 A rating, the C curve and the 6 kA rating — all four must match the outgoing device. A refurbished unit is tested against OEM datasheet specifications and functionally verified by our sourcing team, with condition stated clearly before you commit.
What to Confirm Before You Order
Start with the existing device: confirm the four-pole configuration, the 32 A rating and the C curve printed on the front. Check that the board’s fault level does not exceed the 6 kA breaking capacity, and confirm the 35 mm DIN rail mounting and the 85 × 72 × 78.5 mm envelope leave room for adjacent devices. Mechanical life is rated at 20,000 cycles and electrical life at 10,000 cycles, so ask for the cycle history where it is available. Operating temperature spans -35 to 70 °C, which suits most indoor distribution rooms. Standards compliance is stated as EN/IEC 60898-1 and EN/IEC 60947-2. Please verify current lifecycle status and availability with Autronexa before ordering, and contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider iC60N 4P C32, or a copy?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before listing it. The breaker is supplied as genuine surplus or refurbished stock, not as a grey-market clone.
What condition will the breaker arrive in?
The site default condition is Refurbished. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team, and the condition is confirmed with you before dispatch.
How fast can you ship the iC60N 4P C32?
Lead time depends on current stock at the time of your request. Contact Autronexa with the part number and we will confirm verified condition and current availability, including the expected dispatch date.
Does the 6 kA rating suit my distribution board?
The device is rated 6 kA at 230/400V under IEC 60898-1. Compare that figure with the prospective fault level at the board before ordering; if the board's fault level is higher, a different rating is needed.
Is the Acti9 iC60 range still supported by Schneider Electric?
The data lists the range as active and in production, last verified in 2026-09. Contact Autronexa to confirm current OEM support status for this specific configuration.
Related & compatible parts
Schneider Electric
TM221C24R
Genuine surplus Schneider Electric TM221C24R Modicon controller — 14 DI, 10 relay DO, 2 analog inputs. Verified condition,…
Schneider Electric
140NOE77111C
Genuine surplus Schneider 140NOE77111C Ethernet module for Modicon Quantum — verified condition, Modbus TCP/IP, ready to ship.
Schneider Electric
170INT11000C
Genuine surplus Schneider 170INT11000C Interbus adaptor — verified, tested, and ready to ship for Modicon Momentum systems.
Schneider Electric
BMXAMO0410
Genuine surplus BMXAMO0410: 4-channel Modicon X80 analog output module, verified condition, faster lead time than OEM.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…