Technical specifications

Module type I/O base (wide)
Base width 18.4 mm
Weight 0.028 kg
Compatible modules STBDAI, STBDAO, STBDRC series
Protection rating IP20
Lifecycle Discontinued (superseded by Modicon X80 range)

Description

When an Advantys STB analog or AC I/O module needs a replacement base, the STBXBA2000 from Schneider Electric is the wide I/O base that carries STB DAI, STBDAO, and STBDRC series modules. Maintenance and procurement teams choose genuine surplus or refurbished units here because the Advantys STB range is discontinued and OEM new stock is no longer a reliable route.

What This Wide I/O Base Does in an Advantys STB System

The STBXBA2000 is a mounting base, not an active module. It provides the physical seat and backplane connection for STB DAI, STBDAO, and STBDRC analog and AC I/O modules inside an Advantys STB island. The 18.4 mm base width is the wide format, so it accepts the wider analog and AC modules that the narrow bases cannot carry. At 0.028 kg, the base adds negligible mechanical load to the DIN rail assembly. The IP20 protection rating tells you this is an in-cabinet component, intended for a clean control enclosure rather than an exposed field location. If you are repairing an existing island rather than designing a new one, matching the base format to the module family is the first check — a narrow base will not seat a wide analog module.

Figure 1: Front view of the Schneider Electric STBXBA2000 Mounting base showing its physical design and enclosure.

Why Genuine Surplus Makes Sense for a Discontinued Base

Schneider Electric has discontinued the Advantys STB range and points users toward the Modicon X80 range. That lifecycle status changes the sourcing math. A passive base like this rarely fails on its own, but it becomes the blocker when a module is swapped or an island is rebuilt and the original base is damaged. OEM new stock is no longer the dependable channel, and grey-market bases with unclear history add risk to a system you are trying to keep running. Autronexa stocks genuine surplus and refurbished units, each checked against OEM datasheet markings and part-number cross-reference before it is listed. For a low-cost passive component, that verification matters more than the price difference — a base that does not seat correctly costs far more in repeat downtime than the part itself.

Figure 2: Technical layout and connection details for the Schneider Electric STBXBA2000 Mounting base.

Sourcing Checks Before You Order

Confirm three things before committing. First, verify the module family on your island: this base is specified for STBDAI, STBDAO, and STBDRC series modules, and the wide 18.4 mm format is the distinguishing physical feature. Second, confirm the condition you need — surplus and refurbished units are both available, and the sourcing team can describe the actual state of a specific unit. Third, plan for the discontinued status: if your maintenance strategy depends on long-term availability, ask about quantity holdings before you standardize on this base. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: STBXBA2000-datasheet.pdf

Frequently asked questions

Is this STBXBA2000 a genuine Schneider Electric base or a copy?

Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before listing. The base is genuine Schneider Electric Advantys STB stock, not a grey-market clone.

What condition will the mounting base arrive in?

Units are supplied as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — ask for the specific condition of current stock.

How fast can you ship the STBXBA2000?

Lead time depends on current stock. Contact Autronexa for the present lead time and availability before placing your order.

Which I/O modules does this base accept?

The wide 18.4 mm base is specified for STBDAI, STBDAO, and STBDRC series analog and AC I/O modules in an Advantys STB island. Confirm your module family before ordering.

Is the Advantys STB range still supported by Schneider Electric?

The range is discontinued and superseded by the Modicon X80 range. Contact Autronexa to verify OEM support status and current availability for your maintenance plan.

Related & compatible parts

Schneider Electric

140AVI03000C

Genuine surplus Schneider Electric 140AVI03000C analog input module for Modicon Quantum — verified condition, sourcing support and faster…

In Stock

Schneider Electric

140CPU67261C

Genuine surplus Schneider 140CPU67261C Hot Standby processor — verified, tested, and ready to ship with sourcing support from…

In Stock

Schneider Electric

TM218LDA24DRN

Genuine surplus Schneider TM218LDA24DRN logic controller — verified, refurbished, ready to ship. Contact Autronexa for current availability.

In Stock

Schneider Electric

140DAI75300C

Genuine surplus Schneider Electric 140DAI75300C: 32-channel 230 VAC discrete input module for Modicon Quantum, verified and ready to…

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: STBXBA2000

We reply within one business day.

STBXBA2000 Quote reply within 1 business day