Technical specifications
| Operating modes | "12 bits" (8 in / 8 out, individually configurable ±10 V or 0...20 mA) and "8 bits" (16 channels in pairs, 0...10 V or 0...20 mA) |
|---|---|
| Rated supply voltage | 24 V DC |
| Max. current consumption | 0.2 A |
| Max. power dissipation | 5 W |
| Permissible operating temperature | 0...55 °C |
| CS31 bus interface | EIA RS-485, electrically isolated |
| Dimensions (W x H x D) | 120 x 140 x 85 mm |
| Weight | 450 g |
| Mounting | DIN rail per DIN EN 50022-35 (15 mm deep) or 4 x M4 screws |
Description
Industrial control systems have evolved from centralized racks to distributed architectures, and the ABB 07 AC 91 analog input/output module reflects that shift. As a remote module on the CS31 system bus, it brings 16 configurable analog channels closer to field devices. Maintenance teams and automation engineers sourcing genuine surplus units get a practical alternative to long OEM lead times — verified condition and clear availability from Autronexa.
What the 07 AC 91 Does in a CS31 System
The module operates in two distinct modes, set via DIL switches under the right-side housing cover. In “12 bits” mode, it provides 8 input channels and 8 output channels, each individually configurable for ±10 V or 0…20 mA with 12-bit resolution. In “8 bits” mode, all 16 channels are configurable in pairs as inputs or outputs, using 0…10 V or 0…20 mA with 8-bit resolution. The CS31 bus interface uses EIA RS-485 and is electrically isolated from the rest of the unit. Up to eight input words and eight output words are used on the bus; in 8-bit mode, two analog values pack into one word. A binary enabling input at terminals 25 (+) and 26 (-) must receive a 24 V signal before analog outputs become active.

Technical Specs That Matter on the Floor
Three specifications directly affect commissioning and reliability. First, the 24 V DC supply draws a maximum of 0.2 A with 5 W power dissipation, and the power connection is protected against reversed polarity. Second, the permitted operating temperature range is 0…55 °C, so cabinet cooling must remain unobstructed — natural convection cooling cannot be blocked by cable ducts. Third, analog cable runs using two-core shielded wire with cross-section greater than 0.5 mm² are limited to 100 m maximum length. The module mounts on DIN rail per DIN EN 50022-35 (15 mm deep) or with four M4 screws, and measures 120 x 140 x 85 mm at 450 g. Removable screw-type terminal blocks handle wiring; supply and bus terminals accept max. 1 x 2.5 mm² or max. 2 x 1.5 mm², all other terminals max. 1 x 1.5 mm².

Why Genuine Surplus Fits This Module
This unit belongs to ABB’s Advant Controller 31 family, and like many CS31 components, new-from-OEM availability can involve extended lead times. Autronexa stocks surplus and refurbished units tested against OEM datasheet specifications and functionally verified by our sourcing team. For maintenance managers, that means genuine parts, verified, without waiting on a production run. Each unit ships with the original scope of delivery where available: one 2-pole terminal block (3.81 mm grid), one 3-pole block (5.08 mm), one 5-pole block (5.08 mm), and four 8-pole blocks (3.81 mm). Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this 07 AC 91 a genuine ABB module or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before listing. The 07 AC 91 carries ABB ordering number GJR5 2523 00 R0101, and we confirm that marking on each module.
What condition will the module arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — contact Autronexa to confirm the specific condition of current stock.
How fast can you ship the 07 AC 91?
Lead time depends on current stock. Contact Autronexa for verified availability and a shipping estimate before ordering.
Does the module include terminal blocks?
Where available, units ship with the original scope of delivery: one 2-pole terminal block (3.81 mm grid), one 3-pole block (5.08 mm), one 5-pole block (5.08 mm), and four 8-pole blocks (3.81 mm). Confirm accessory inclusion with Autronexa at the time of order.
Is the 07 AC 91 still supported by ABB?
Lifecycle status is not stated in our data. Please verify current lifecycle status and availability with Autronexa before ordering.
Related & compatible parts
ABB
TB846
Genuine surplus ABB TB846 Modulebus inlet module — verified condition, clear lead times, and sourcing help from Autronexa.
ABB
PM867K02
Genuine surplus ABB PM867K02 Redundant Processor Unit HI (3BSE081638R1) — SIL3-certified, verified condition, ready to ship from Autronexa.
ABB
TB820V2
Genuine surplus ABB TB820V2 Cluster Modem — fiber optic ModuleBus interface, verified condition, faster lead time than OEM.
ABB
CI540
Genuine surplus ABB CI540 S100 I/O Bus Extension module — verified condition, tested against OEM datasheet specs, ready…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…