ABB AX522
Analog input/output module
Genuine surplus ABB AX522 analog I/O module — 8 AI, 8 AO, 12-bit, verified and ready to ship from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Channels | 8 AI, 8 AO |
|---|---|
| Input ranges | 0 V…10 V, -10 V…+10 V, 0 mA…20 mA, 4 mA…20 mA, Pt100/1000, Ni1000 |
| Resolution | 12 bits (0 V…10 V, 0/4 mA…20 mA); 12 bits + sign (-10 V…+10 V) |
| Conversion cycle | 2 ms (8 inputs + 8 outputs); 1 s with Pt/Ni |
| Input resistance | Voltage: > 100 kW; Current: ca. 330 W |
| Input filter time constant | 100 µs (voltage and current) |
| Max. analog cable length | 100 m (> 0.14 mm²) |
| Rated supply | 24 VDC, max. ripple 5 % |
| Weight | 300 g |
Description
Industrial control has moved from relay logic to distributed I/O, and analog modules like the ABB AX522 analog input/output module now carry the measurement burden once handled by separate signal conditioners. This 8 AI / 8 AO unit gives maintenance teams a genuine surplus path when an OEM replacement is weeks out. Autronexa verifies each unit against OEM datasheet markings before it ships.
What the AX522 Does in a Control Cabinet
The module combines eight analog inputs and eight analog outputs in one housing, configurable per channel for 0 V…10 V, -10 V…+10 V, 0 mA…20 mA, 4 mA…20 mA, Pt100/1000 and Ni1000. Input resolution reaches 12 bits on the 0 V…10 V, 0 mA…20 mA and 4 mA…20 mA ranges, and 12 bits plus sign on the bipolar -10 V…+10 V range. A 2 ms conversion cycle covers all eight inputs and eight outputs together; switching to Pt/Ni temperature channels extends that cycle to 1 s. Each input carries its own LED, so a technician can confirm signal presence at the terminal without a meter. The module is galvanically isolated per module, and unused voltage inputs are configured as “unused” while unused current inputs present a low resistance and can be left open-circuited.

Technical Specs That Matter on the Floor
Three values drive most selection decisions. First, channel input resistance: voltage inputs exceed 100 kW, while current inputs sit at approximately 330 W — a difference that affects loop loading and must be matched to the transmitter. Second, the input filter time constant is 100 µs on both voltage and current paths, fast enough for pressure and flow loops but still filtering switching noise. Third, analog cable length is rated to 100 m with conductor cross-section above 0.14 mm², which covers most cabinet-to-field runs without repeaters. Conversion error stays at typically ±0.5 % of full scale at 25 °C and max ±1 % of full scale across 0 °C…60 °C or under EMC disturbance.

Why Genuine Surplus Fits This Module
ABB has long product cycles, but a failed analog card still stops a line. Surplus and refurbished stock gives maintenance managers a practical alternative to waiting on factory allocation. Every unit we list is tested against OEM datasheet specifications and functionally verified by our sourcing team — genuine parts, verified, not pulled from an unknown bin. The module weighs 300 g and mounts horizontally or vertically with derating (output load reduced to 50 % at 40 °C per group), so it drops into existing cabinet space. Natural convection cooling must not be blocked by cable ducts or other parts in the switchgear cabinet. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine ABB AX522, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished ABB modules, not grey-market copies.
What condition will the AX522 arrive in?
Our default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade confirmed before purchase.
How fast can you ship the AX522?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus and refurbished units are ready to ship once confirmed.
Can the AX522 handle Pt100 sensors on all eight inputs?
Yes. Each input is individually configurable for Pt100/1000 or Ni1000, though the conversion cycle extends to 1 s when temperature channels are used. Bipolar input mode is not available with current or Pt100/Pt1000/Ni1000 configurations.
Is the AX522 still supported by ABB?
Lifecycle status is not stated in our current data. Contact Autronexa to verify OEM support status and availability before ordering.
Related & compatible parts
ABB
CI920AB
Genuine surplus ABB CI920AB communication interface for S900 I/O — PROFIBUS DP-V1, ATEX Zone 2, verified and ready…
ABB
PTB810K01
Genuine surplus ABB PTB810K01 power injection terminal block for Select I/O TUS810 MTUs — verified condition, clear lead…
ABB
CI867A
Genuine surplus ABB CI867A Modbus TCP module for AC 800M — verified, tested, and ready to ship from…
ABB
DI828
Genuine surplus ABB DI828 digital input module — 16 isolated channels, 120V AC/DC, verified and ready to ship.
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…