Technical specifications
| Article Number | 3BSE008534R1 |
|---|---|
| Mechanics | S800 |
| Corrosion Protection | ISA-S71.04: G3 |
| Operating Temperature | 0 to +55 °C |
| Storage Temperature | -25 to +70 °C |
| Relative Humidity | 5 to 95 % no condensation |
| Protection Class | IP20 according to IEC 60529 |
| Dimensions (W x D x H) | 22 mm x 25 mm x 109 mm |
| Weight | 46 g |
Description
The ABB TB805 ModuleBus Cable Adaptor (3BSE008534R1) lets you extend the ModuleBus so I/O modules on the same electrical bus can be mounted on different DIN rails. Maintenance teams and integrators use this adaptor with TB806 and TK801V0xx cables to spread cabinet layouts without losing bus continuity. Autronexa supplies genuine surplus and refurbished units, verified against OEM datasheet markings, so you get a practical alternative to long OEM lead times.
What the TB805 Does in an S800 System
This unit works as a bridge between ModuleBus segments. In an S800 installation, it pairs with the TB806 and a TK801V0xx cable to carry the electrical ModuleBus from one DIN rail to another. That means you can distribute I/O modules across separate rails while keeping them on the same bus — useful when cabinet space or panel layout forces a split. The adaptor is part of ABB’s S800 mechanics family, and its 22 mm width, 25 mm depth and 109 mm height keep it compact on the rail. At 46 g, it adds little mechanical load. The unit carries CE marking and is built to IEC 61131-2 electrical safety, with an IP20 protection class per IEC 60529. For panel builders and maintenance engineers, this is a straightforward way to extend an existing ModuleBus without redesigning the whole rail arrangement.

Surplus Advantage: Why Refurbished Makes Sense Here
A ModuleBus adaptor is a passive interconnect — it has no firmware to age and no moving parts to wear. That makes genuine surplus and refurbished unit units a practical sourcing option when an OEM order would stall a panel build or a maintenance window. Autronexa’s refurbished stock is tested against OEM datasheet specifications and functionally verified by our sourcing team, so you know the unit matches the published electrical and mechanical profile before it ships. The adaptor’s corrosion protection is rated ISA-S71.04: G3, which tells you it is intended for controlled industrial environments; a refurbished unit that has been stored and handled correctly will retain that rating. Compared with waiting on a factory lead time, surplus stock often shortens the path to a working panel. If your maintenance schedule is tight, ask us for current availability and condition notes on the specific unit.
Selection and Sourcing Guide
Before you order a unit, confirm three things. First, check that your application uses the TB806 and TK801V0xx cable combination — the adaptor is designed to work as part of that extension set, not as a stand-alone part. Second, verify the article number 3BSE008534R1 against your existing documentation; ABB uses this number to identify the exact ModuleBus cable adaptor variant. Third, decide whether you need surplus or refurbished condition and confirm any accessory items you already hold. Autronexa can cross-reference the part number and provide condition details so you are not guessing. The adaptor’s operating temperature range is 0 to +55 °C, with storage from -25 to +70 °C at 5 to 95 % RH non-condensing, so check that your cabinet environment stays within those limits. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine ABB TB805 ModuleBus Cable Adaptor, or a copy?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference. The TB805 carries article number 3BSE008534R1, and we confirm that marking before shipping.
What condition will the TB805 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade.
How fast can you ship the TB805?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus units are often ready to ship faster than OEM factory orders.
Does the TB805 work with my existing S800 I/O setup?
The TB805 is designed for use with TB806 and TK801V0xx cables to extend the ModuleBus across DIN rails. Confirm your cable and termination arrangement matches that combination before ordering.
Is the TB805 still supported by ABB?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before you commit to a maintenance plan.
Related & compatible parts
ABB
TB846
Genuine surplus ABB TB846 Modulebus inlet module — verified condition, clear lead times, and sourcing help from Autronexa.
ABB
SD831
Genuine surplus ABB SD831 power supply: 24 V DC, 3 A, 72 W, DIN-rail mount. Verified condition, faster…
ABB
V18347-2041150001
Genuine surplus ABB TZIDC-120 electro-pneumatic positioner with FOUNDATION Fieldbus, ATEX EEx ia IIC T6, verified and ready to…
ABB
DI810
Genuine surplus ABB DI810 digital input module, 16 channels, 24 V d.c., S800 mechanics — verified condition from…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…