ABB V18347-2041150001
Switches SJ2_x0001_S1N
Genuine surplus ABB TZIDC-120 electro-pneumatic positioner with FOUNDATION Fieldbus, ATEX EEx ia IIC T6, verified and ready to source.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Type | TZIDC-120 Electro-Pneumatic Positioner |
|---|---|
| Input/Communication Port | FOUNDATION Fieldbus |
| Explosion Protection | ATEX EEx ia IIC T6 |
| Output/Safe Position | Single acting, fail safe |
| Case/Mounting | Aluminium, varnished, mechanical position indicator; DIN/IEC 534/NAMUR or VDI/VDE 3845 |
| Ambient Temperature | –40 °C to +85 °C operation, storage and transport |
| Protection Class | IP 65 / NEMA 4X |
| Pneumatic Connection | 1/4-18 NPT |
| Weight | 1.7 kg |
Description
The ABB V18347-2041150001 is a TZIDC-120 electro-pneumatic positioner for FOUNDATION Fieldbus, built for maintenance teams that need a verified, intelligent positioner without waiting on OEM lead times. Autronexa supplies genuine surplus and refurbished units with condition checked before dispatch.
What This Positioner Does on the Valve
The TZIDC-120 sits between the control system and the actuator, converting a FOUNDATION Fieldbus signal into a pneumatic output that moves the valve stem. This variant is single acting with fail-safe output, so the actuator drives to its safe position if electrical power is lost. The aluminium case carries a mechanical position indicator and an operator panel, which lets a technician read valve position at the housing without opening anything. Mounting follows DIN/IEC 534/NAMUR for linear actuators or VDI/VDE 3845 for rotary actuators, so it fits standard valve hardware rather than requiring an adapter. The case is varnished black RAL 9005 and rated IP 65 / NEMA 4X, which suits washdown-adjacent and outdoor installations where dust and hose spray are routine. Pneumatic piping connects at 1/4-18 NPT, and the cable entry uses an M20 x 1.5 thread.

Environmental Limits and Service Access
The unit operates from –40 °C to +85 °C, and that range holds for storage and transport as well, which matters when a spare sits in an unheated warehouse for months before it is needed. With proximity switches SJ2_x0001_S1N fitted, the low end rises to –25 °C. Operational humidity is 95 % annual average with condensation permissible, provided the housing is closed and air supply is on; transport and storage allow 75 % non-condensing. For service work, the screw terminals accept max. 1.0 mm2 for options and max. 2.5 mm2 for the analog signal, and ABB’s own notice applies: do not expose the terminals to strain. Explosion protection is ATEX EEx ia IIC T6, so the unit suits hazardous-area loops within that rating. There is no shutdown option module and no mechanical digital position feedback kit on this configuration, which keeps the bill of materials simple for a like-for-like replacement.

Why Genuine Surplus Fits This Model
Positioners are often pulled from service during turnarounds while still functional, and those units re-enter the surplus chain. A refurbished TZIDC-120 is tested against OEM datasheet specifications and functionally verified by our sourcing team before it ships, so the FOUNDATION Fieldbus communication and fail-safe output are checked rather than assumed. Compared with ordering new from the OEM, surplus stock shortens the wait on a valve that is holding up a loop. Autronexa sources across ABB, Allen-Bradley, Bently Nevada, Siemens and Schneider, and our team works with these systems daily, so you can confirm the exact configuration, including the M20 x 1.5 cable entry and 1/4-18 NPT air connection, before committing. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine ABB TZIDC-120 positioner, or a copy?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before listing. The V18347-2041150001 configuration includes FOUNDATION Fieldbus input and ATEX EEx ia IIC T6 protection, and those markings are checked on the actual unit.
What condition will the positioner arrive in?
Our default supply condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need the specific condition grade recorded for the unit currently in stock.
How fast can you ship the V18347-2041150001?
Lead time depends on current stock. Contact Autronexa for the present lead time and availability; surplus and refurbished units are ready to ship once condition verification is complete.
Does this unit work on a FOUNDATION Fieldbus segment?
Yes. The input/communication port is FOUNDATION Fieldbus per the datasheet. Segment design, wiring and termination remain the responsibility of your control system engineering team.
Is the TZIDC-120 still supported by ABB?
Lifecycle status is not stated in our source data. Contact Autronexa to verify OEM support status before you plan a long-term spares strategy around this model.
Related & compatible parts
ABB
DO880
Genuine surplus ABB DO880 16-channel digital output module, verified and ready to ship for S800 systems.
ABB
DI820
Genuine surplus ABB DI820 digital input module — 8 isolated channels, 120 V a.c./110 V d.c., verified condition…
ABB
3HAC038457-001
Genuine ABB 3HAC038457-001 Weldguide III Basic — verified surplus stock with clear lead times. Contact Autronexa for availability.
ABB
AX522
Genuine surplus ABB AX522 analog I/O module — 8 AI, 8 AO, 12-bit, verified and ready to ship…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…