ABB V18345-1010551001
Valve Positioner
Genuine surplus ABB TZIDC-120 positioner, 4...20 mA two-wire, IP 65, double acting fail freeze — verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Product type | TZIDC-120 Intelligent Positioner: V18345 |
|---|---|
| Input / communication port | Input 4...20 mA, two-wire with connector plug for LKS adapter |
| Output / safe position | Double acting, fail freeze |
| Explosion protection | Without |
| Housing | Aluminium, varnished, IP 65 (NEMA 4X) |
| Connections | Cable: Thread M20 x 1.5; Air pipe: Thread 1/4-18 NPT |
| Output range | 0...6 bar (0...90 psi) |
| Option module | Plug-in analog position feedback (signal range 4...20 mA) |
Description
When a control valve drifts or stops responding mid-process, how quickly can you get a genuine replacement positioner into the loop? The ABB V18345-1010551001 answers that question: a TZIDC-120 intelligent positioner with a 4…20 mA two-wire input, built for linear and rotary actuators. Autronexa supplies it as verified surplus or refurbished stock, so you avoid OEM lead times without risking a clone.
What This TZIDC-120 Variant Actually Does
The TZIDC-120 family converts a 4…20 mA control signal into precise pneumatic valve travel. This variant carries the two-wire input with a connector plug for an LKS adapter, so commissioning follows the standard TZIDC workflow. The aluminium case is varnished to the standard design and rated IP 65 (NEMA 4X), which suits mounting to linear actuators per DIN/IEC 534 / NAMUR or rotary actuators per VDI/VDE 3845, including integral mounting.
Two configuration details matter most for spares matching. First, the output is double acting with fail freeze: on electrical power failure the actuator is blocked rather than vented, so the valve holds its last position. Second, this unit ships without explosion protection and without the optional mechanical kit for digital position feedback. Buyers replacing a unit in a hazardous area should confirm their existing nameplate before ordering.

Why Genuine Surplus Fits This Positioner
Positioners sit in the control loop, so a copy with unverified calibration behaviour is a risk you cannot absorb. Autronexa sources genuine ABB units and verifies each against OEM datasheet markings and part-number cross-reference before it enters stock. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team, covering the input range, digital input thresholds and pneumatic output range.
Availability is the practical argument. New-build lead times on positioner variants can stretch, while a verified surplus unit is often ready to ship. The pneumatic side is straightforward to check on receipt: the output range is 0…6 bar (0…90 psi), with air capacity of 5.0 kg/h at 1.4 bar supply and 13 kg/h at 6 bar supply. Cable entry is M20 x 1.5 and the air pipe connection is 1/4-18 NPT, so existing gland and tubing hardware usually carries over.

Sourcing Checklist Before You Order
Confirm four things against the unit you are replacing. Check the full configuration string, not just the TZIDC-120 family name, because the suffix encodes output function, connections and option modules. Confirm the fail-freeze double-acting output matches your actuator. Confirm whether your installation needs explosion protection, since this variant is supplied without it. Finally, confirm the analog position feedback option your loop expects; this unit’s feedback configuration should be matched to the existing wiring.
Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine ABB TZIDC-120 positioner, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished ABB components, not grey-market copies.
What condition will the positioner arrive in?
The site default condition is Refurbished. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a surplus unit in as-removed condition instead.
How fast can you ship the V18345-1010551001?
Lead time depends on current stock at the time of your request. Contact Autronexa for current lead time and availability; verified surplus units are often ready to ship.
Does this variant include explosion protection?
No. The configuration string specifies explosion protection option 0 - without. If your installation requires an intrinsically safe device, confirm the correct variant with Autronexa before ordering.
What is the fail-safe behaviour on power loss?
This unit is configured for double acting, fail freeze: on electrical power failure the actuator is blocked rather than vented, so the valve holds position. Confirm this matches your actuator and process requirement.
Related & compatible parts
ABB
TU841
Genuine surplus ABB TU841 termination unit for non-redundant I/O — verified condition, practical lead times, sourcing support from…
ABB
DO801
Genuine surplus ABB DO801 16-channel 24 V digital output module for S800 I/O — verified condition, tested, and…
ABB
SD834
Genuine surplus ABB SD834 power supply, 24 V d.c. 20 A, 480 W, DIN-rail. Verified condition and clear…
ABB
DI830
Genuine surplus ABB DI830 16-channel digital input module for S800 I/O — verified condition, faster than OEM lead…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…