ABB DI825
Cable length 600 meters
Genuine surplus ABB DI825, 8-channel 125 V d.c. digital input for S800 I/O, individually isolated, verified and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Article number | 3BSE036373R1 |
|---|---|
| Signal specification | 125 V d.c. |
| Number of channels | 8 |
| Input voltage range, "1" | 71 .. 156 V |
| Input impedance | 41.5 kΩ |
| Maximum field cable length | 600 meters (656 yards) |
| Operating temperature | 0 to +55 °C |
| Protection class | IP20 according to IEC 60529 |
| Dimensions (W x D x H) | 45 x 102 x 119 mm |
| Weight | 0.14 kg (0.31 lbs.) |
Description
The ABB DI825 is an 8-channel 125 V d.c. digital input module for the S800 I/O system, built for maintenance and procurement teams who need a genuine, verified replacement without OEM lead-time delays. Each channel is individually isolated and carries its own status LED, so fault finding stays local to the field wiring. Autronexa supplies this module as tested surplus or refurbished stock, functionally checked against the published datasheet before it ships.
What the DI825 Does in an S800 I/O Rack
The module reads eight digital input signals and reports them to the S800 I/O system over the ModuleBus. Every input channel combines current-limiting components, EMC protection, an input state indication LED and an optical isolation barrier. Channel 1 can serve as a voltage supervision input for channels 2–4, and channel 8 can do the same for channels 5–7. If the supervised voltage disappears, the module sets a channel error and turns on the Warning LED; the error signal is readable from the ModuleBus. Sequence of event (SOE) functionality records transitions with 0.4 ms resolution and event recording accuracy of -0.25 ms to 1.0 ms. Selectable digital filter times run from 0 to 100 ms, which helps reject contact bounce on long field runs.

Technical Specifications Buyers Should Confirm
This unit accepts 125 V d.c. signals with a “1” input voltage range of 71 to 156 V and a “0” range of 0 to 20 V. Input impedance is 41.5 kΩ, and input current is 3.0 mA at 125 V. The maximum field cable length is 600 meters (656 yards), which suits long runs in process areas. The module is rated for 0 to +55 °C operating temperature, with approvals issued for +5 to +55 °C, and carries IP20 protection according to IEC 60529. Power dissipation peaks at 4.9 W, and +5 V ModuleBus current consumption is a maximum of 90 mA. The unit is 45 mm wide, 102 mm deep (111 mm including connector) and 119 mm high, weighing 0.14 kg. It is CE marked and complies with RoHS Directive 2011/65/EU and WEEE Directive 2012/19/EU.
Surplus Advantage and Sourcing Guidance
For a module that sits in a running S800 I/O rack, the practical question is not list price but how fast a verified unit can reach the panel. Genuine surplus and refurbished stock often closes that gap when OEM lead times stretch. Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference, then functionally checks it before dispatch. When you request a quote, confirm the keying code AB and the MTU pairing: the module is used with TU811, TU813, TU831, TU839 and TU851, and TU811V1 is the matching MTU listed for this product. Ask for the exact article number 3BSE036373R1 on the label, and state whether you need surplus or refurbished condition. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine ABB DI825, or a clone or copy?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference, including the article number 3BSE036373R1. We supply genuine surplus and refurbished modules, not grey-market clones.
What condition will the DI825 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available; state your preference when requesting a quote.
How fast can you ship the DI825?
Contact Autronexa for current lead time. Stocked surplus and refurbished units are ready to ship once condition and availability are confirmed for your order.
Which MTUs work with this module?
The DI825 is used with MTU types TU811, TU813, TU831, TU839 and TU851. TU811V1 is the matching MTU listed for this product. Confirm your MTU model before ordering.
Is the DI825 still supported by ABB?
Contact Autronexa to verify OEM support status. We can confirm current lifecycle information and availability before you commit to an order.
Related & compatible parts
ABB
DO818
Genuine surplus ABB DO818 digital output module for S800 I/O — 32 channels, 24 V d.c., verified condition…
ABB
AI523
Genuine surplus ABB AI523 S500 analog input module — 16 channels for U, I, RTD and DI signals,…
ABB
V18345-2010420001
Genuine surplus ABB TZIDC positioner, 4–20 mA two-wire, IP 65, double acting fail safe — verified condition and…
ABB
TB846
Genuine surplus ABB TB846 Modulebus inlet module — verified condition, clear lead times, and sourcing help from Autronexa.
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…