ABB TU811V1
ModuleBus to the I/O module and to the next MTU
Genuine surplus ABB TU811V1 compact MTU: 8 channels, 250 V, DIN-rail mounting, verified condition and fast lead times from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Channels | 8 |
|---|---|
| Voltage | 250 V |
| Maximum current per channel | 3 A |
| Wire size (solid) | 0.2 - 4 mm² |
| Wire size (stranded) | 0.2 - 2.5 mm², 24 - 12 AWG |
| Stripping length | 7 mm |
| Operating temperature | 0 to +55 °C |
| Protection class | IP20 |
| Dimensions (W x D x H) | 64 x 64 x 170 mm |
| Weight | 0.17 kg |
Description
What slows down a control system upgrade more than the engineering itself? Often it is the wait for a genuine termination unit that matches the existing S800 I/O footprint. The ABB TU811V1 is an 8-channel, 250 V compact module termination unit (MTU) that connects field wiring to I/O modules and carries the ModuleBus forward. Sourcing a verified surplus or refurbished unit from Autronexa keeps your maintenance schedule on track without OEM lead-time delays.
What This Compact MTU Does in an S800 I/O System
The TU811V1 is a passive termination unit for ABB S800 I/O. It provides the physical connection point for field wiring and distributes the ModuleBus to the I/O module and to the next MTU in the chain. Two mechanical keys give 36 possible configurations, helping prevent insertion of the wrong I/O module. The unit is designed for single (non-redundant) I/O and works with DI820, DI821, DO820, and DO821 modules. Its compact DIN-rail design includes a latching device for grounding. The MTU handles up to 8 isolated channels at 250 V, with a maximum current of 3 A per channel. For wiring, it accepts solid conductors from 0.2 to 4 mm² and stranded conductors from 0.2 to 2.5 mm² (24–12 AWG). The recommended stripping length is 7 mm. The dielectric test voltage is 2000 V a.c. Operating temperature range is 0 to +55 °C, though approvals are issued for +5 to +55 °C. The unit carries CE marking and meets EN 61010-1 and UL 61010-1 safety standards, with marine certifications from ABS, BV, DNV-GL, and LR. Corrosion protection is rated ISA-S71.04: G3.

Why Genuine Surplus Makes Sense for This MTU
New-from-OEM lead times for S800 I/O components can stretch weeks or longer, especially for mature product lines. A verified surplus or refurbished unit from Autronexa offers a practical alternative: the same form, fit, and function, tested against OEM datasheet specifications and functionally verified by our sourcing team. Because this MTU is a passive unit with no firmware or configuration memory, its reliability depends mainly on mechanical integrity and terminal condition. Our refurbishment process checks terminal blocks, keying mechanisms, and ModuleBus contacts. You get a genuine ABB part with clear condition notes and current availability, not a grey-market clone. For maintenance teams managing aging S800 installations, surplus stock often means shorter downtime and lower total cost than waiting on a new-build order.

Sourcing Checklist for This unit
Before ordering, confirm the exact article number 3BSE013231R1 and that your application uses single (non-redundant) I/O. Verify compatibility with your specific I/O module: DI820, DI821, DO820, or DO821. Check the mechanical key configuration matches your module type, as incorrect keying will prevent insertion. Review the wire size range for your field wiring: solid 0.2–4 mm² or stranded 0.2–2.5 mm². Confirm the operating temperature at your mounting location, noting the reduced maximum ambient for vertical mounting. When sourcing surplus, ask for condition details and any available test records. Autronexa provides verified condition notes and practical lead times. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine ABB TU811V1, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished ABB parts, not grey-market copies.
What condition will the TU811V1 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available; condition notes are provided before purchase.
How fast can you ship the TU811V1?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; we typically ship faster than OEM lead times.
Does this MTU work with DI820, DI821, DO820, and DO821 modules?
Yes, the TU811V1 is designed for use with those I/O modules. The mechanical keying must be configured to match your specific module type.
Is the TU811V1 still supported by ABB?
Lifecycle status can vary. Please verify current lifecycle status and availability with Autronexa before ordering.
Related & compatible parts
ABB
07 KT 95
Genuine surplus ABB 07 KT 95 control unit with 12 digital inputs, 8 digital outputs, 4 analog inputs,…
ABB
DI810
Genuine surplus ABB DI810 digital input module, 16 channels, 24 V d.c., S800 mechanics — verified condition from…
ABB
FENA-11
Genuine surplus ABB FENA-11 Ethernet adapter for ACS880 drives — verified condition, faster than OEM lead times.
ABB
TU814V1
Genuine surplus ABB TU814V1 termination unit — 16 I/O channels, 50 V rated, crimp snap-in connectors. Verified condition,…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…