ABB V18345-1010261001
Valve Positioner
Genuine surplus ABB TZIDC valve positioner, 4–20 mA two-wire, IP65 aluminum case, fail-safe single acting — verified and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Input signal | 4...20 mA, two-wire with connector plug for LKS adapter |
|---|---|
| Output / safe position | Single acting, fail safe |
| Housing material / protection | Aluminum, IP 65 / NEMA 4X |
| Supply pressure | 1.4 ... 6 bar (20 ... 90 psi) |
| Air consumption | < 0.03 kg/h / 0.015 scfm (independent of supply pressure) |
| Pneumatic connections | Threads G 1/4 or 1/4-18 NPT |
| Cable entry | Thread M20 x 1.5 |
| Weight | 1.7 Kg |
| Position feedback | Plug-in module analog position feedback (4 ... 20 mA) |
Description
When a control valve loses its positioner, the loop goes manual and production suffers. The ABB V18345-1010261001 TZIDC valve positioner restores precise 4–20 mA two-wire control with a fail-safe single-acting output, and Autronexa supplies it as a genuine surplus or refurbished unit — verified against OEM datasheet markings and functionally tested, so you avoid OEM lead times without risking a clone.
What This TZIDC Variant Delivers
This is the intelligent, configurable TZIDC positioner with integral indicator and operator panel, built into a varnished aluminum case rated IP 65 / NEMA 4X. The case mounts to linear actuators per DIN/IEC 534 / NAMUR or rotary actuators per VDI/VDE 3845, and it is ready for integral mounting. The electrical input is a 4–20 mA two-wire signal with a connector plug for an LKS adapter. Output configuration is single acting, fail safe — on electrical power failure the valve moves to its safe position. A plug-in analog position feedback module (4–20 mA) is fitted; the mechanical digital feedback kit is not included. Cable entry uses an M20 x 1.5 thread, and the air pipe connection is G 1/4. Supply pressure range is 1.4 to 6 bar (20 to 90 psi), and air consumption stays below 0.03 kg/h (0.015 scfm) independent of supply pressure. The unit weighs 1.7 kg.

Why Surplus Beats Waiting for OEM
A failed positioner on a critical valve often means weeks of OEM lead time — or paying a premium for expedited new stock. Genuine surplus and refurbished units close that gap. Every TZIDC positioner we supply is inspected for case integrity, terminal condition, and pneumatic port threads, then tested against the OEM datasheet specifications and functionally verified by our sourcing team. You get the same form, fit, and 4–20 mA behavior as the original, at a fraction of OEM list price. Because this variant is a specific configuration — analog feedback, no explosion protection, single-acting fail-safe — matching the exact suffix matters. Autronexa cross-references the full part number so you receive the correct build, not a lookalike.

Sourcing Checklist for This Positioner
Before ordering, confirm three things. First, verify the actuator interface: this unit suits linear actuators per DIN/IEC 534 / NAMUR or rotary actuators per VDI/VDE 3845, and integral mounting is supported. Second, check the electrical interface — the 4–20 mA two-wire input with LKS adapter plug must match your control system; if your loop uses a different signal, this is not the right variant. Third, confirm the fail-safe direction: single acting, fail safe means the valve drives to a defined safe position on power loss. Also note the M20 x 1.5 cable entry and G 1/4 air connection; adapters may be needed if your existing piping uses 1/4-18 NPT. This unit carries no explosion protection, so it is not for hazardous areas. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this ABB V18345-1010261001 a genuine unit or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished ABB positioners, not grey-market copies.
What condition will the positioner arrive in?
Our default condition is Refurbished: the unit is inspected, tested against OEM datasheet specifications, and functionally verified by our sourcing team before shipment.
How fast can you ship the V18345-1010261001?
Lead time depends on current stock. Contact Autronexa for current availability and lead time — surplus units typically ship faster than OEM factory orders.
Does this positioner work with my existing 4–20 mA control loop?
Yes, this variant has a 4–20 mA two-wire input with a connector plug for an LKS adapter. Confirm your control system matches this signal before ordering.
Is the ABB TZIDC still supported by ABB?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before ordering.
Related & compatible parts
ABB
TU805K01
Genuine surplus ABB TU805K01 kit: 10 pcs TU805 16-channel 50 V terminal units for S800 I/O DI801/DO801. Verified…
ABB
TU890
Genuine surplus ABB TU890 MTU for S800 I/O — verified condition, 8 channels, intrinsic-safety ready, ready to ship…
ABB
DI814
Genuine surplus ABB DI814 digital input module: 16 channels, 24 V d.c., 600 m field cable length. Verified…
ABB
FENA-21
Genuine ABB FENA-21 dual-port Ethernet adapter for drives — PROFINET IO, EtherNet/IP, Modbus TCP. Verified surplus, ready to…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…