Flexem F5-MD0032N
Terminal block
Genuine surplus Flexem F5-MD0032N 32-point terminal block with NPN/PNP outputs, 24VDC rated voltage, and short circuit protection.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Output Characteristics | 32 Point |
|---|---|
| Output Type | NPN(PNP) |
| Rated Voltage | 24VDC |
| Voltage Range | 19.2~28.8VDC |
| Rated Current | 0.5A |
| Current/group | 0.5A Output point of each group |
| Voltage/drop | Maximum 1VDC |
| Leakage Current When Turned Off | <5μA |
| Maximum Power of Incandescent Lamp | 2.4W |
| Derating | None |
| Start Time | Maximum 34μs |
| Turn-off Time | Maximum 250μs |
| Maximum Output Frequency | 1KHz |
| Short Circuit Protection | Available |
| Peak Short-circuit Output Current | 1.3A |
Description
When a 32-point output card fails on a running control panel, every hour of downtime adds cost. The Flexem F5-MD0032N terminal block delivers 32 output points with NPN/PNP configuration at a rated 24VDC, making it a practical replacement for genuine surplus sourcing. Autronexa supplies this unit as a verified surplus or refurbished component, helping maintenance teams restore panel functionality without waiting on standard OEM lead times.
What the F5-MD0032N Terminal Block Does in Your Panel
This unit is a 32-point output terminal block designed for industrial control cabinets. It operates at a rated voltage of 24VDC with a voltage range of 19.2~28.8VDC, and each output group carries a rated current of 0.5A. The module includes short circuit protection with a peak short-circuit output current of 1.3A, and it self-recovers after a short circuit or overload every 10ms. For engineers replacing a failed output block, these ratings mean This unit can handle typical 24VDC solenoid, relay, and indicator loads without external fusing in many panel designs. The removable terminal block wiring structure simplifies field replacement, and the unshielded cable length rating of 50m supports distributed I/O layouts.

Why Genuine Surplus Makes Sense for This Output Block
This unit is a current-production Flexem part, but OEM lead times can still stall a maintenance window. Autronexa maintains verified surplus and refurbished stock of Flexem terminal blocks, including this 32-point model. Each unit is inspected for physical condition and tested against the published datasheet ratings, such as the 500V AC isolation between output and internal logic and the maximum 1VDC voltage drop. For plants carrying spares, a refurbished unit offers a practical alternative to a full-list-price purchase. Our sourcing team can confirm current condition and availability before you commit.

Selection and Sourcing Guide for This unit
Before ordering a replacement unit, verify the output type your panel requires: this model supports NPN and PNP configuration, so confirm the existing wiring matches. Check the clamping voltage maximum of 39VDC, ±1V, against your load devices. Also review the maximum output frequency of 1KHz and the turn-off time maximum of 250μs if your application involves fast switching. Because This unit uses a removable terminal block, confirm the mating connector is present or order it separately. Autronexa provides hands-on sourcing help across Flexem and other automation brands, so contact us with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Flexem F5-MD0032N, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. The F5-MD0032N we supply is a genuine Flexem component, sourced as surplus or professionally refurbished.
What condition will the F5-MD0032N arrive in?
Units are supplied as refurbished by default, tested against the published datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for current condition details on specific stock.
How fast can you ship the F5-MD0032N?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability.
Does the F5-MD0032N support both NPN and PNP output types?
Yes, the F5-MD0032N is listed with an output type of NPN(PNP), so it can be configured for either output arrangement. Confirm your panel wiring before installation.
Related & compatible parts
Flexem
FE6400C
Genuine Flexem FE6400C HMI: 10.1-inch 1024x600 resistive touch, dual-core ARM, DC 24V. Verified surplus and refurbished units from…
Flexem
F5-MA0402A
Genuine surplus Flexem F5-MA0402A analog expansion module with 4 inputs, 4/2 outputs, 16-bit resolution, and 24 VDC power.
Flexem
FR-A0004M
Flexem Analog Output Module FR-A0004M: 4-channel analog input, 16-bit resolution, ±10V, 0~20mA
Flexem
F5-BA0200B
Genuine surplus Flexem F5-BA0200B expansion board with 12-bit resolution and 0-10V or 0-20mA/4-20mA signal range, verified and ready…
News & guides for Flexem
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…