MTL IOP HC32
Drive solenoids
Genuine MTL IOP HC32 surge protector for one high-current loop up to 5A, with 20kA hybrid protection and zero loop resistance.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Maximum rated load current | 5A (IOP HC32) |
|---|---|
| Maximum surge current | 20kA (8/20µs waveform) per line |
| Loop resistance | 0 ohm (IOP HC32) |
| Leakage current | <1µA @ working voltage |
| Response time | <1ns |
| Terminals | 2.5mm2 (12 AWG) |
| Mounting | T-section DIN-rail (35 x 15mm rail) |
| Case flammability | UL94-V0 |
Description
How do you protect a high-current solenoid circuit from surges without adding resistance that dulls response? The MTL IOP HC32 answers that question with a 5A-rated surge protector built for one high-current loop, combining a 20kA hybrid circuit with 0 ohm series resistance so the driven load sees no added impedance.
What the IOP HC32 Does in a Solenoid Circuit
This unit belongs to the MTL IOP range of surge protection devices for digital and analogue I/O. Its specific role is protecting circuits that drive solenoids, relays and actuators at load currents up to 5A. The hybrid circuit pairs 20kA gas discharge tubes with solid-state components, and the module reacts in under 1ns to redirect surges between lines or to ground. Because series resistance is 0 ohm, the protector adds no measurable voltage drop to the loop. The module occupies 12mm of DIN rail width for its single loop, mounts on T-section 35 x 15mm rail, and uses plug/header screw terminals accepting 2.5mm2 (12 AWG) conductors. Removable terminals allow a loop disconnect by unplugging them from the side of the module.

Technical Specs That Matter for High-Current Loops
Three values define this model’s fit. First, the 5A maximum rated load current separates the HC32 from the 0.675A rating of the rest of the IOP family, so it suits solenoid drive circuits rather than signal-level I/O. Second, the 0 ohm loop resistance means the protection stays electrically transparent to the load. Third, the 20kA maximum surge current per line, rated on an 8/20µs waveform, gives the module its surge-handling capacity. Leakage current stays below 1µA at working voltage, and the case carries a UL94-V0 flammability rating. This unit is not bandwidth-rated, which reflects its role on slower, higher-current drive circuits rather than high-frequency signal lines.

Why Genuine Surplus Makes Sense for This Module
Surge protectors are often replaced on a schedule or after a known surge event, so tested surplus units fit the maintenance cycle well. Autronexa supplies genuine surplus and refurbished unit modules, each checked against OEM datasheet specifications and functionally verified before dispatch. That approach gives maintenance teams a practical alternative to waiting on OEM lead times for a part that protects a single loop. Because the module resets automatically after diverting a surge, a verified unit returns to service without intervention. Confirm the exact model and condition when you enquire, since the IOP family includes single-loop, dual-loop and AC variants with different ratings.
Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is the MTL IOP HC32 a genuine unit or a copy?
Autronexa verifies each IOP HC32 against OEM datasheet markings and part-number cross-reference before it is listed. Units are genuine surplus or professionally refurbished, not grey-market clones.
What condition will the IOP HC32 arrive in?
Units are supplied refurbished as standard, tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask Autronexa to confirm the condition grade on the specific unit before ordering.
How fast can Autronexa ship the IOP HC32?
Contact Autronexa for current lead time on the IOP HC32. Stock levels for surplus modules change with incoming batches, so the team confirms availability at the time of your request.
Can the IOP HC32 protect a 5A solenoid loop?
Yes. The IOP HC32 is rated for one high-current loop up to 5A, with 0 ohm series resistance and a 20kA maximum surge current per line on an 8/20µs waveform.
Related & compatible parts
MTL
MTL4041P
Genuine surplus MTL4041P isolator: high-power 4-20mA loop driver for hazardous-area transmitters, verified and ready to ship from Autronexa.
MTL
SD32R
Genuine surplus MTL SD32R surge protector with 32 Vdc nominal voltage, 400 mA nominal current, and high bandwidth…
MTL
SD16R
Genuine MTL SD16R surge protection device with 50MHz bandwidth and <1ns response time. Verified surplus and refurbished units…
MTL
SD55X
Genuine surplus MTL SD55X surge protection device with 55 VDC nominal voltage and low resistance, verified and ready…
News & guides for MTL
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…