General Electric IS200EPDMG1ABA
Mounted on the side
Genuine surplus IS200EPDMG1ABA from General Electric: a verified EX2100 Exciter Power Distribution Module, tested and ready to ship from Autronexa.
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
Technical specifications
| Board Description | Exciter Power Distribution Module (EPDM) |
|---|---|
| Series | EX2100 |
| DC Source Supply | P125V and N125V |
| Nominal Voltages to Ground | +62.5 V and -62.5 V |
| Power Supply from Station Battery | 125 VDC |
| Number of Channels | 12 |
| Analog Output Current | 0-20 mA |
| Operating Temperature | -30 to 65 °C |
| Size | 8.26 cm high x 4.19 cm |
Description
The IS200EPDMG1ABA is a General Electric Exciter Power Distribution Module for the EX2100 series, distributing power from a 125 VDC station battery to protection, I/O, and control boards. Autronexa supplies this module as genuine surplus, verified against OEM datasheet markings and functionally tested before dispatch.
What this unit Does in an EX2100 System
this unit takes 125 VDC from the station battery and delivers the P125V and N125V source supplies that feed the exciter’s control, I/O, and protection boards. It mounts on the side of the IS200EPBP backplane. With the center grounded, the module presents nominal voltages of +62.5 V and -62.5 V to ground. Outputs can reach three EPSM modules, one EXTB board, and up to three EGPA boards. The board carries seven toggle switches and twelve female plug connectors, two of which are twelve-position types. Its analog output current range is 0-20 mA, and the input span is 4-20 mA. Operating temperature is rated from -30 to 65 °C, and the board measures 8.26 cm high by 4.19 cm.

Why Genuine Surplus Fits This Module
When an EPDM fails, the exciter loses its distribution path for control and protection power, so replacement speed matters. Autronexa holds verified surplus and refurbished stock of General Electric EX2100 components, including this module. Each unit is checked against OEM datasheet markings and functionally verified by our sourcing team. That gives you a practical alternative to waiting on a factory order, with clear condition notes before you commit. This unit is listed as in stock, and the manual reference is GEI-100511 for wiring and setup details.

Sourcing Checks Before You Order
Confirm the part number this unit and the EX2100 series match your backplane before ordering. Ask for the condition grade, since surplus and refurbished units differ in cosmetic and test history. Verify that your station battery supply is 125 VDC and that the DACA module is present for AC-to-DC conversion. The board is rated for a common mode voltage range of ±5 V and a maximum lead resistance of 15 Ω. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is the IS200EPDMG1ABA a genuine General Electric module or a clone?
Autronexa verifies each IS200EPDMG1ABA against OEM datasheet markings and part-number cross-reference before listing it. The module is supplied as genuine surplus, not a grey-market copy.
What condition will the IS200EPDMG1ABA arrive in?
Units are supplied as surplus or refurbished, with condition noted before dispatch. Our sourcing team functionally verifies each IS200EPDMG1ABA against the OEM datasheet specifications.
How fast can Autronexa ship the IS200EPDMG1ABA?
The IS200EPDMG1ABA is listed as in stock. Contact Autronexa for current lead time and availability before placing your order.
Does the IS200EPDMG1ABA work with SCADA systems?
The IS200EPDMG1ABA supports integration with SCADA systems via protocols such as RS-232, RS-485, and Ethernet, according to the manufacturer's specification.
Related & compatible parts
FANUC · FANUC System 3/5/6 CNC
A02B-0047-C311
Genuine surplus FANUC A02B-0047-C311 HMI option unit for System 3/5/6 CNC, verified and ready to ship from Autronexa.
Bently Nevada · 31000 / 32000 Series
32000-28-05-06-020-07-02
Bently Nevada 32000-28-05-06-020-07-02 Proximity Probe Housing. Standoff Adapter: 60 mm; Probe Penetration: 20 mm.
Allen-Bradley
22C-B017H103
Genuine surplus Allen-Bradley 22C-B017H103 PowerFlex 400 drive: 3.7 kW, 17.5 A, 200…240V AC, IP20 plate mount. Verified condition…
ABB
TU830V1
Genuine surplus ABB TU830V1 termination unit — 16 channels, DIN rail mount, tested and ready for your S800…
News & guides for General Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…