Schneider Electric Communication Modules

Schneider Electric 140CRA21120

Typical backplanes

Manufacturer: Schneider Electric Part Number: 140CRA21120

Genuine surplus Schneider 140CRA21120 DIO drop interface for Modicon Quantum — verified condition, faster than OEM lead time.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Supply voltage limits 20…30 V
Maximum supply current 1.6 A at 24 V
Number of ports 2 redundant
Output voltage 5.1 V
Nominal output current 3 A
I/O words 30 I/32 O
Power dissipation 11 W
Operating temperature 32…140 °F (0…60 °C)
Relative humidity 95 % without condensation
Operating altitude <= 16404.2 ft (5000 m)

Description

How do you keep a Modicon Quantum DIO network running when a drop interface fails and the OEM lead time stretches into weeks? The Schneider Electric 140CRA21120 DIO drop interface is the genuine surplus answer: a 24 V DC, two-port redundant module that maintenance and procurement teams rely on to restore distributed I/O communications without paying full list price or waiting on factory backorders. Autronexa stocks verified surplus and refurbished units, tested and ready to ship.

What This DIO Drop Interface Does in a Quantum System

The 140CRA21120 is a DIO drop interface for the Modicon Quantum automation platform. It links the Quantum controller to distributed I/O drops, and its two redundant ports let you maintain communications if one path fails. The module accepts a 24 V DC supply and tolerates a 20…30 V range, so it fits standard control cabinet power without extra conditioning. It delivers a 5.1 V output at up to 3 A nominal, with short-circuit and overvoltage protection built in. The 7-pole terminal block keeps wiring straightforward, and the standard module format slots into the typical backplanes listed for this family. With 30 input and 32 output words, the unit handles a meaningful I/O load per drop. Power dissipation is 11 W, which matters when you calculate enclosure heat load.

Figure 1: Front view of the Schneider Electric 140CRA21120 Typical backplanes showing its physical design and enclosure.

Why Genuine Surplus Fits This Module

Schneider no longer prioritizes every legacy Quantum component for fast factory shipment, and a failed drop interface can idle an entire I/O segment. Autronexa sources genuine surplus and refurbished unit units through verified channels. Each unit is checked against OEM datasheet markings and functionally verified by our sourcing team before it ships. You get the authentic module — not a grey-market clone — at a fraction of OEM list price, with lead times that reflect stock on hand rather than factory scheduling. For maintenance managers, that means restoring the drop without a capital request or a multi-week wait.

Figure 2: Technical layout and connection details for the Schneider Electric 140CRA21120 Typical backplanes.

Sourcing Checklist Before You Order

Confirm the exact part number and revision match your existing Quantum drop configuration. Decide whether you need surplus or refurbished condition — both are genuine, and our team states the condition clearly on every quote. Verify that your backplane position count and terminal block wiring match the original installation. Ask about the 24 V DC supply limits and the 1.6 A maximum supply current if your cabinet power budget is tight. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is this 140CRA21120 a genuine Schneider Electric module or a clone?

Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it ships. The 140CRA21120 we supply is genuine Schneider Electric surplus or refurbished stock, not a grey-market copy.

What condition will the 140CRA21120 arrive in?

Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available and clearly labeled as such on your quote.

How fast can Autronexa ship the 140CRA21120?

Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability — we confirm lead time before you order.

Does the 140CRA21120 work with my existing Modicon Quantum backplane?

This module is a DIO drop interface for the Modicon Quantum platform and fits the typical backplane positions listed for the family. Confirm your backplane position count and terminal block wiring with our team before ordering.

Is the 140CRA21120 still supported by Schneider Electric?

Lifecycle status varies by production date. Contact Autronexa to verify OEM support status and current availability for your specific unit.

Related & compatible parts

Schneider Electric

170BSM01600

Genuine surplus Schneider 170BSM01600 16-channel input simulator — verified, tested, and ready to ship from Autronexa.

In Stock

Schneider Electric

LMC058LF424

Genuine surplus Schneider LMC058LF424 Modicon LMC058 motion controller — 4 axes, 42 I/O, verified condition and clear lead…

In Stock

Schneider Electric

TSXCANCB50

Genuine surplus Schneider Electric TSXCANCB50 CANopen cable, 50 m, IP20, UL — verified condition with practical lead times…

In Stock

Schneider Electric

TM3AI2H

Genuine surplus Schneider TM3AI2H analog input module — 2 channels, 16-bit, verified condition, ready to ship.

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: 140CRA21120

We reply within one business day.

140CRA21120 Quote reply within 1 business day