Technical specifications

Range of Product Modicon Quantum automation platform
Product or Component Type DIO drop interface
Number of Ports 1 single
[Us] Rated Supply Voltage 115/230 V AC
Supply Voltage Limits 85…276 V
Supply Frequency 47...63 Hz
Maximum Supply Current 0.2 A 115 V / 0.4 A 230 V
Output Voltage 5.1 V
Nominal Output Current 3 A
I/O Words 30 I/32 O

Description

The 140CRA21110 is a Schneider Electric DIO drop interface for the Modicon Quantum automation platform, rated for 115/230 V AC supply. Maintenance and procurement teams choose genuine surplus or refurbished units to avoid OEM lead times and keep Quantum systems running without paying full list price. Autronexa verifies each unit against OEM datasheet markings before it ships.

What This Modicon Quantum Interface Does

This DIO drop interface links a Quantum controller to distributed I/O drops over a single port. It accepts 115/230 V AC supply and tolerates a wide input range of 85…276 V, so it suits plants where supply voltage varies. The unit provides 5.1 V output at 3 A nominal, with short-circuit and overvoltage protection built in. It handles 30 input and 32 output words, supporting typical backplane configurations of 2, 3, 4, 6, 10, and 16 positions. A 7-pole terminal block handles connections, and the standard module format fits existing Quantum racks. Diagnostics cover RAM address and checksum at startup and during run time.

Figure 1: Front view of the Schneider Electric 140CRA21110 Typical backplanes showing its physical design and enclosure.

Why Genuine Surplus Fits This Interface

OEM lead times for legacy Quantum components can stretch weeks, and new-from-OEM pricing on discontinued lines often exceeds the value of the part itself. Autronexa stocks genuine surplus and refurbished 140CRA21110 units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. Each unit is inspected for terminal condition, output stability, and diagnostic function before dispatch. For maintenance managers supporting installed Quantum systems, this means a verified spare without the wait or the premium. Surplus and refurbished, ready to ship — with clear condition notes on every order.

Figure 2: Technical layout and connection details for the Schneider Electric 140CRA21110 Typical backplanes.

Sourcing Checklist for This DIO Drop Interface

Before ordering, confirm the exact model and revision match for your Quantum rack, and verify that your backplane position count aligns with the supported configurations. Check whether your application requires the 115 V or 230 V supply setting and confirm the associated 1.5 A fuse rating is correct for your panel. Ask for condition details: surplus units may show minor cosmetic wear, while refurbished units are cleaned and tested. Autronexa provides verified condition reports and can cross-reference your existing part number. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: 140CRA21110-datasheet.pdf

Frequently asked questions

Is this a genuine Schneider Electric 140CRA21110, or a clone?

Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We source only genuine surplus and refurbished components, not grey-market copies.

What condition will the 140CRA21110 arrive in?

Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — contact us for current condition options.

How fast can you ship the 140CRA21110?

Lead time depends on current stock. Contact Autronexa for current availability and lead time — we ship verified units as quickly as possible.

Does this interface work with my existing Modicon Quantum backplane?

The 140CRA21110 supports typical backplane configurations of 2, 3, 4, 6, 10, and 16 positions. Confirm your rack position count and supply voltage before ordering.

Related & compatible parts

Schneider Electric

140DAI74000

Genuine surplus Schneider Electric 140DAI74000: 16-channel 230 V AC discrete input module for Modicon Quantum, verified and ready…

In Stock

Schneider Electric · Advantys STB

STBACO8220

Genuine surplus Schneider STBACO8220: 2-channel HART analog output, 4-20 mA, 15-bit, hot-swappable. Verified condition, sourcing help from Autronexa.

In Stock

Schneider Electric

140AVO02000C

Genuine surplus Schneider 140AVO02000C analog output module — 4 channels, verified condition, ready to ship from Autronexa.

In Stock

Schneider Electric

170NEF16021C

Genuine surplus Schneider 170NEF16021C Modbus Plus adapter for Modicon Momentum — verified condition, faster than OEM lead time.

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: 140CRA21110

We reply within one business day.

140CRA21110 Quote reply within 1 business day