Technical specifications
| Poles | 4P |
|---|---|
| Rated current | 16A |
| Trip curve | C (thermal-magnetic, magnetic trip 8×In ±20%) |
| Breaking capacity | 6 kA @ 230/400V (IEC 60898-1) |
| Rated voltage | 400V AC |
| Standard | EN/IEC 60898-1, EN/IEC 60947-2 |
| Operating temperature | -35 to 70 °C |
| Mounting | 35 mm DIN rail |
| Mechanical life | 20,000 cycles |
| Electrical life | 10,000 cycles |
| Dimensions (H×W×D) | 85 × 72 × 78.5 mm |
| Weight | 0.5 kg |
Description
When a 4-pole feeder trips in a live distribution board, every hour of downtime adds cost. The Schneider Electric iC60N 4P C16 is a genuine Acti9 miniature circuit breaker rated 16A with a C-curve trip, and Autronexa supplies verified surplus and refurbished units so you can restore the circuit without waiting on OEM lead times.
What This Acti9 Breaker Does in a Panel
The iC60N sits in the Acti9 iC60 family of DIN-rail miniature circuit breakers. This 4-pole version protects three-phase circuits plus neutral, with a 16A rated current and a C-curve thermal-magnetic trip whose magnetic threshold is 8×In ±20% — a profile that tolerates brief inrush from small motors and transformers while still clearing short circuits. Rated voltage is 400V AC, and breaking capacity is 6 kA at 230/400V under IEC 60898-1. The unit mounts on standard 35 mm DIN rail, measures 85 × 72 × 78.5 mm, and weighs 0.5 kg. It carries dual standards coverage — EN/IEC 60898-1 and EN/IEC 60947-2 — so it fits both domestic-style and industrial distribution designs.

Technical Specs That Matter for Replacement
Three figures drive most replacement decisions. First, the 6 kA breaking capacity sets the maximum prospective fault current the breaker can safely interrupt at 230/400V; check it against your panel’s calculated fault level before installing. Second, the C-curve magnetic trip at 8×In ±20% distinguishes this unit from B- or D-curve alternatives — substituting a different curve changes coordination with upstream and downstream devices. Third, endurance is stated as 20,000 mechanical cycles and 10,000 electrical cycles, so a refurbished unit with verified operation still has substantial service life. Operating temperature spans -35 to 70 °C, covering most industrial enclosure environments.
Why Genuine Surplus Fits This Breaker
The Acti9 range is active in production, but OEM channel lead times on individual configurations can still stall a maintenance window. Autronexa holds surplus and refurbished stock of genuine units, each tested against OEM datasheet specifications and functionally verified by our sourcing team. That means you get the correct 4-pole, 16A, C-curve configuration — not a lookalike — with practical lead times and savings against OEM list price. For panel builders and maintenance teams standardising on Acti9, this is a straightforward way to keep spares on the shelf. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this iC60N 4P C16 a genuine Schneider Electric breaker or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before listing. This is a genuine Schneider Electric Acti9 iC60 breaker, not a grey-market copy.
What condition will the breaker arrive in?
Units ship in our default refurbished condition — tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact us if you need a specific condition grade.
How fast can you ship the iC60N 4P C16?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus units typically move faster than OEM channel orders.
Does this breaker work with standard DIN-rail panels?
Yes — it mounts on 35 mm DIN rail, the standard for Acti9 iC60 devices, and is rated 400V AC with 6 kA breaking capacity at 230/400V.
Is the iC60N 4P C16 still supported by Schneider Electric?
The Acti9 range is listed as active in production as of our last verification in 2026-09. Confirm current lifecycle status with Autronexa before ordering.
Related & compatible parts
Schneider Electric
STBDDI3420K
Genuine surplus STBDDI3420K digital input kit for Modicon STB — 4 DC inputs, verified condition, faster than OEM…
Schneider Electric · Advantys STB
STBDDO3230
Genuine surplus STBDDO3230 digital output module — 2-channel, 2 A, hot-swappable. Verified condition, ready to ship from Autronexa.
Schneider Electric
ATV320U22N4W
Genuine surplus Schneider ATV320U22N4W, 2.2 kW IP66 drive with C2 EMC filter — verified condition and clear lead…
Schneider Electric
ABE7E16EPN20
Genuine surplus Schneider Electric ABE7E16EPN20 passive discrete I/O sub-base — 16 channels, 24 V DC, verified condition, ready…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…