Vibro Meter Cables & Connectors

Vibro Meter 143-104-000-101

Cables depending on the required temperature

Manufacturer: Vibro Meter Part Number: 143-104-000-101

Genuine surplus Vibro Meter 143-104-000-101 cable for CP 104 pressure transducers, verified for high-temperature service up to +350°C.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Sensitivity 190 pC/bar nominal
Dynamic measuring range 0.00005 bar to 20 bar nominal
Overload capacity Up to 100 bar
Frequency response 2 to 6000 Hz ±5%
Temperature range -196°C to +350°C
Capacitance 85 pF pole/pole, 30 pF pole/ground
Mounting 3 Allen screws M5, 10 Nm

Description

The Vibro Meter 143-104-000-101 is a cable assembly for the CP 104 piezoelectric pressure transducer, specified for high-temperature operation. Maintenance and instrumentation teams choose genuine surplus or refurbished cables like this one to keep critical pressure monitoring running without long OEM waits.

Product Overview

The 143-104-000-101 belongs to the Vibro Meter CP 104 family of compression-mode dynamic pressure transducers. The CP 104 uses a VC2 single-crystal element for stable long-term monitoring and development testing. This cable variant is selected according to the required operating temperature. The transducer itself operates from -196°C to +350°C, so cable choice must match the application’s thermal profile. The CP 104 delivers a charge output through a 2-pole system insulated from the casing, and signal processing is handled by a charge converter. Because input power requirements are none, the transducer is passive at the sensor end, making cable integrity essential for a clean signal. This unit is the practical link between the transducer and your charge converter in high-temperature installations.

Figure 1: Front view of the Vibro Meter 143-104-000-101 Cables depending on the required temperature showing its physical design and enclosure.

Key Specifications at a Glance

Parameter Value
Sensitivity 190 pC/bar nominal
Dynamic measuring range 0.00005 bar to 20 bar nominal
Overload capacity Up to 100 bar
Frequency response 2 to 6000 Hz ±5%
Temperature range -196°C to +350°C
Capacitance 85 pF pole/pole, 30 pF pole/ground
Mounting 3 Allen screws M5, 10 Nm

These figures describe the CP 104 transducer interface that This unit cable serves. The cable must preserve the low-noise charge path across the full 2 to 6000 Hz band. At 190 pC/bar nominal sensitivity, even small cable capacitance shifts can affect readings, so the 85 pF pole/pole and 30 pF pole/ground values are useful reference points during verification. The Inconel 600, hermetically welded construction of the transducer body also signals the environmental class this cable is expected to support.

Figure 2: Technical layout and connection details for the Vibro Meter 143-104-000-101 Cables depending on the required temperature.

Surplus Advantage for This Cable

High-temperature piezoelectric cables are often long-lead items. This unit is a genuine surplus and refurbished candidate because it is a passive accessory with no internal electronics to age. Autronexa verifies each cable against OEM datasheet markings and part-number cross-reference before it ships. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. For a transducer with no input power requirements and a factory dynamic calibration at 1 bar peak and 2 Hz, the cable is the only wear item in the signal chain. Sourcing a verified surplus cable keeps a calibrated CP 104 in service without repeating the full transducer purchase. Contact Autronexa with your part number for verified condition and current availability.

Selection and Sourcing Guide

Buyers should confirm three things before ordering This unit. First, match the cable to the actual temperature at the measurement point, since the CP 104 spans -196°C to +350°C and cable selection depends on that range. Second, verify connector and pole configuration against the 2-pole, case-insulated signal transmission arrangement. Third, confirm the cable length and routing suit the 3 Allen screw M5 mounting at 10 Nm torque. Surplus and refurbished, ready to ship options are available through Autronexa, and our team can help cross-reference the exact revision.

📄 Download Datasheet: 143-104-000-101-datasheet.pdf

Frequently asked questions

Is the Vibro Meter 143-104-000-101 a genuine part or a clone?

Autronexa verifies each 143-104-000-101 against OEM datasheet markings and part-number cross-reference before listing it as genuine surplus or refurbished stock.

What condition will the 143-104-000-101 cable arrive in?

Units are supplied as refurbished unless otherwise stated. Refurbished cables are tested against OEM datasheet specifications and functionally verified by our sourcing team.

How fast can Autronexa ship the 143-104-000-101?

Contact Autronexa for current lead time on the 143-104-000-101. Surplus and refurbished stock is ready to ship once condition and availability are confirmed.

Does the 143-104-000-101 suit high-temperature CP 104 installations?

The CP 104 transducer operates from -196°C to +350°C, and cable selection depends on the required temperature. Confirm your measurement-point temperature with Autronexa before ordering.

Related & compatible parts

Vibro Meter

111-412-000-013-A1-B1-E050-F1-G050-H05

Genuine surplus Vibro Meter proximity measuring system with 5 m integral cable and flexible hose, verified and ready…

In Stock

Vibro Meter

143-216-000-011

Genuine surplus Vibro Meter 143-216-000-011 cable for CP 216 piezoelectric pressure transducers, verified and ready for dynamic pressure…

In Stock

Latest news & guides

View all articles

Request a quote for this part

Part number: 143-104-000-101

We reply within one business day.

143-104-000-101 Quote reply within 1 business day