Woodward I/O & Function Modules
Woodward 5441-693
Field Terminal Module
Genuine Woodward 5441-693 Field Terminal Module with 24 optically isolated inputs, 1 ms timestamping, and in-stock availability for PLC systems.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Number of Input Channels | 24 |
|---|---|
| Input Type | Optically isolated discrete input |
| Update Time | 5 ms |
| Time Stamping | 1 ms resolution |
| Isolated 24 Vdc Contact Supply | 400 mA maximum |
| Relay Circuits | 13 |
| Availability | In Stock |
| Repair | 3-7 Day |
| Country of Manufacture | United States (USA) |
Description
The Woodward 5441-693 is a Field Terminal Module that provides 24 optically isolated discrete input channels for PLC systems, with 1 ms time-stamping resolution and a 5 ms update time. Engineers specifying this module need a genuine unit that matches the original interface and timing behavior, and Autronexa supplies verified surplus and refurbished stock to meet that requirement.
Product Overview and Series Context
The 5441-693 belongs to Woodward’s line of discrete I/O modules designed for insertion into card guides within a control chassis and connection to the motherboard. Two screws at the top and bottom of the front panel secure the module, while toggling the two handles outward disengages the board connectors for removal. This mechanical arrangement allows maintenance teams to swap a module without disturbing adjacent cards.
Functionally, the module serves as a relay module with 13 relay circuits, providing the PLC with the ability to switch electrical loads based on control signals received through a single interface port. The 24 input channels monitor external devices and sensors, detecting on/off or high/low states. An isolated 24 Vdc contact supply delivers up to 400 mA maximum, supporting field devices without an external supply in many configurations.

Technical Specs Breakdown
Three specifications drive most selection decisions for this module. First, the 1 ms time-stamping resolution allows the PLC to place input events in sequence with millisecond accuracy, which matters in applications where the order of discrete events determines the control response. Second, the 5 ms update time defines how quickly the module refreshes input data to the controller; engineers should confirm this rate matches the scan cycle of the host PLC. Third, the optically isolated discrete input design separates field wiring from the module’s internal electronics, reducing the risk of electrical noise and transient damage reaching the control system.
The isolated 24 Vdc contact supply at 400 mA maximum is a practical constraint worth noting during system design. Count the total current draw of all field contacts powered from this supply before commissioning, and add margin for inrush where inductive devices are involved.

Surplus Advantage for This unit
Woodward controls are often embedded in turbine, engine, and process systems where production cannot wait for a long OEM lead time. Autronexa maintains verified surplus and refurbished stock of Woodward modules, and This unit is currently in stock. Each refurbished unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch. The repair option of 3-7 days applies where a unit requires service, giving maintenance planners a defined window rather than an open-ended wait.
Because this module is manufactured in the United States, buyers replacing a failed card in an existing chassis can source a matching configuration without changing the system architecture. The single interface port and 13 relay circuits are fixed characteristics of the model, so the primary verification task is confirming the part number and revision against the chassis documentation.
Selection and Sourcing Guide
Before ordering, confirm three things. Check that your chassis documentation specifies This unit rather than a different Woodward I/O variant, since relay count and channel configuration differ across the family. Confirm the condition you require: surplus, refurbished, or repaired, and note that Autronexa can advise on current grading. Finally, verify that the host PLC’s input timing requirements align with the 1 ms timestamping and 5 ms update figures.
Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is the Woodward 5441-693 a genuine module or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before listing. The 5441-693 is supplied as genuine surplus or refurbished stock, not as a grey-market copy.
What condition will the 5441-693 arrive in?
Units are supplied refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you require a specific condition grade or a repair option, which runs 3-7 days.
How fast can Autronexa ship the 5441-693?
The 5441-693 is currently in stock. Contact Autronexa for current lead time and shipping arrangements to your location.
Does the 5441-693 work with my existing PLC chassis?
The module inserts into card guides in a Woodward control chassis and connects to the motherboard through a single interface port. Confirm your chassis documentation specifies the 5441-693 before ordering, as relay count and channel configuration vary across the family.
Related & compatible parts
Woodward
5464-654
Genuine surplus Woodward 5464-654 discrete output module with 32 channels and 5 ms update time. Verified condition and…
Woodward
5464-643
Genuine surplus Woodward 5464-643 discrete input module with 48 optically isolated channels and 3 mA input current, verified…
Woodward
5464-213
Genuine surplus Woodward 5464-213 Netcon Serial I/O Module for 5400 Series turbine control, verified and ready to ship…
Woodward
5464-648
Genuine surplus Woodward 5464-648: 8-channel 4-20mA analog output module for gas turbine control systems, verified and ready to…
News & guides for Woodward
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…