Honeywell Cables & Connectors

Honeywell 2MLF-DC8A

Cable program or parameters

Manufacturer: Honeywell Part Number: 2MLF-DC8A

Genuine surplus Honeywell 2MLF-DC8A analog output module with 8 current channels and selectable DC 4~20mA or DC 0~20mA ranges.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Output Type Current Output
Number of Channels 8 channels
Output Range DC 4 ~ 20mA / DC 0 ~ 20mA
Load Resistance 550Ω or less
Range Selection Through applicable program or parameters (respective channels)

Description

When an analog output channel drifts or fails on a running control system, maintenance engineers need a genuine replacement they can trust. The Honeywell 2MLF-DC8A is an eight-channel current output module for the MasterLogic-200 series, offering selectable DC 4~20mA or DC 0~20mA output ranges per channel through the applicable program or parameters. Autronexa supplies this module as verified surplus or refurbished stock, giving you a practical alternative to long OEM lead times.

What the 2MLF-DC8A Does in a Control System

This unit is a current output module, not a cable or parameter file. It provides eight independent output channels, each configurable for either DC 4~20mA or DC 0~20mA operation. Because the output range is selected through the applicable program or parameters for each channel, you can match the module to the field device requirements without changing hardware. The load resistance rating of 550Ω or less tells you the module can drive typical current-loop instruments within that limit. For maintenance teams, this means one spare module can cover multiple loop types across the plant, simplifying spares holding and reducing the number of variants you need to stock.

Figure 1: Front view of the Honeywell 2MLF-DC8A Cable program or parameters showing its physical design and enclosure.

Surplus Advantage for Maintenance Engineers

Keeping a genuine unit on the shelf is a practical reliability measure. When a channel fails, you can swap the module and restore the loop without waiting for a factory order. Autronexa sources surplus and refurbished Honeywell modules and verifies each unit against OEM datasheet markings and part-number cross-reference. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. This approach gives you a verified spare with clear lead times, which is often more practical than holding a brand-new unit at full list price. For maintenance engineers, the priority is a module that works when fitted, and genuine surplus stock supports that goal.

Figure 2: Technical layout and connection details for the Honeywell 2MLF-DC8A Cable program or parameters.

Selection and Sourcing Guide

Before ordering, confirm the exact model number unit and check that your application requires current output, not voltage output. Verify the channel count and output range against your loop schedule. If you are replacing an existing module, note any revision markings on the original unit and share them with your supplier. Autronexa can help you confirm compatibility with your MasterLogic-200 configuration and advise on condition options. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: 2MLF-DC8A-datasheet.pdf

Frequently asked questions

Is the 2MLF-DC8A a genuine Honeywell module or a clone?

Autronexa verifies each 2MLF-DC8A against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished units, not grey-market copies.

What condition will the 2MLF-DC8A arrive in?

Units are supplied as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus condition may also be available; confirm at the time of order.

How fast can Autronexa ship the 2MLF-DC8A?

Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability.

Can the 2MLF-DC8A output range be changed per channel?

Yes. The output range can be selected through the applicable program or parameters for respective channels, supporting DC 4~20mA or DC 0~20mA as required.

Related & compatible parts

Honeywell

10302/2/1

Genuine surplus Honeywell 10302/2/1 watchdog repeater, verified and ready to ship for multiple-PSU configurations.

In Stock

Honeywell

05701-A-0284

Genuine surplus Honeywell 05701-A-0284 catalytic sensor drive, verified and ready to ship from Autronexa.

In Stock

Honeywell

CC-PCF901

Genuine surplus Honeywell CC-PCF901 Control Firewall Module for FTE cable distribution to Series C FIMs and C300 controllers.

In Stock

Honeywell

05701-A-0283

Genuine surplus Honeywell 05701-A-0283 Sensor Drive Module for reliable 4-20mA sensor signal conditioning and power supply in gas…

In Stock

News & guides for Honeywell

View all articles

Request a quote for this part

Part number: 2MLF-DC8A

We reply within one business day.

2MLF-DC8A Quote reply within 1 business day