Honeywell I/O & Function Modules
Honeywell 2MLF-HO2A
High Speed Counter Module
Genuine surplus Honeywell 2MLF-HO2A high-speed counter module: 200 kHz, 2-channel, open-collector input. Verified condition and clear lead times from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Product Type | MasterLogic-200 High Speed Counter Modules |
|---|---|
| Input Type | Open Collector type |
| Frequency | 200 kHz |
| Channels | 2 channel |
| Operating Temperature | 0~55°C |
| Storage Temperature | -25~+70°C |
| Operating Humidity | 5~95%RH, no condensation |
| Storage Humidity | 5~95%RH, no condensation |
| Environment | No corrosive gas or dust |
| Altitude | Below 2000 m |
Description
When a high-speed counter module fails on a running MasterLogic-200 system, pulse counting and position feedback stop, and production visibility drops. The Honeywell 2MLF-HO2A is a MasterLogic-200 high-speed counter module with two open-collector input channels rated at 200 kHz. Autronexa supplies this module as genuine surplus and refurbished stock, verified before dispatch, so maintenance teams can restore counting functions without waiting on OEM lead times.
What the 2MLF-HO2A Does in a MasterLogic-200 System
This unit is a dedicated high-speed counter module for Honeywell’s MasterLogic-200 platform. It accepts open-collector input signals at up to 200 kHz across two channels, making it suitable for fast pulse trains from encoders, flow meters, or proximity sensors. In a typical configuration, the module counts pulses independently of the main processor scan, which helps preserve accuracy when the controller is busy with other tasks. Engineers specify this module when a standard digital input cannot keep pace with the signal frequency. This unit fits directly into the MasterLogic-200 backplane and reports counts to the CPU for use in control logic, totalizing, or speed calculation. Because it is a dedicated counter module, it offloads high-frequency counting from the main CPU and supports deterministic response in time-sensitive applications.

Why Genuine Surplus Makes Sense for This Counter Module
The MasterLogic-200 series is widely deployed in process and manufacturing environments, and replacement modules are often needed long after the original installation. OEM lead times for legacy automation components can stretch from weeks to months, while a verified surplus unit can be dispatched quickly. Autronexa sources genuine Honeywell unit modules from decommissioned systems and refurbishes them to datasheet specifications. Each unit is inspected for physical condition, and the open-collector input channels are functionally verified. This approach gives maintenance managers a practical alternative to full list price without compromising authenticity. Surplus and refurbished, ready to ship — that is the model we work to. For buyers comparing options, the key is to confirm the exact model number and condition grade before ordering, since This unit is specific to the MasterLogic-200 series.

Environmental Limits and Installation Checks
This unit is rated for operating temperatures of 0~55°C and storage temperatures of -25~+70°C. Operating and storage humidity must stay within 5~95%RH, no condensation. The module should be installed in an environment free of corrosive gas or dust, at altitudes below 2000 m, with a contamination level below 2. These limits matter in panel design: if the enclosure is near a washdown area or exposed to fine particulate, additional protection may be needed. Before fitting a replacement, inspect the backplane connector for bent pins and confirm that the slot is clean. After installation, verify that the open-collector input signals are within the module’s expected range and that counting registers respond correctly in the controller. For ongoing reliability, include the module in periodic panel inspections and check for dust accumulation on the faceplate.
Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is the Honeywell 2MLF-HO2A a genuine module or a clone?
Autronexa verifies every 2MLF-HO2A against OEM datasheet markings and part-number cross-reference before listing. We supply genuine surplus and refurbished units, not grey-market copies.
What condition will the 2MLF-HO2A arrive in?
Units are supplied as refurbished unless otherwise stated. Each module is inspected for physical condition and functionally verified for open-collector input operation. Contact Autronexa for the current condition grade of available stock.
How fast can Autronexa ship the 2MLF-HO2A?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; we confirm dispatch timing before you order.
Does the 2MLF-HO2A work with any MasterLogic-200 CPU?
The 2MLF-HO2A is a MasterLogic-200 high-speed counter module. Compatibility depends on your specific CPU and backplane configuration. Share your system details with Autronexa and we will help confirm the match.
Related & compatible parts
Honeywell
TC-FIL081
Genuine surplus Honeywell TC-FIL081 thermocouple input: 8 channels, 16-bit resolution, and support for Type B through Type TXK/XK…
Honeywell
2MLI-CPUH
Genuine surplus Honeywell 2MLI-CPUH MasterLogic-200 PLC with 6,144 I/O points and 3.5 MB program memory. Verified condition, ready…
Honeywell
10313/1/1
Genuine surplus Honeywell 10313/1/1 module distributes 5 V DC and watchdog signals across FSC I/O backplanes with verified…
Honeywell
2MLF-AV8A
Genuine surplus Honeywell 2MLF-AV8A analog input module with 8 channels for MasterLogic ML200 PLC systems, verified and ready…
News & guides for Honeywell
Honeywell spare parts: buying guide, series overview and how to order
Honeywell spare parts buying guide: 3 parts online, popular series, condition options and how our RFQ process works.
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…