Emerson 499AOZ-54-03CC
Rosemount Analytical 499AOZ Dissolved Ozone Sensor
Genuine Emerson Rosemount 499AOZ-54-03CC dissolved ozone sensor, new in factory packing with 12-month warranty, available through Autronexa's verified surplus network.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Ambient Temperature | 32 to 122 °F (0 to 50 °C) |
|---|---|
| Weight | 1 lb (0.5 kg) |
| Shipping Weight | 3 lb (1.5 kg) |
| Transmitter Compatibility | Rosemount 1056, 1066-DO, 56, and 5081-A |
| Cable | Integral 33-ft. (10 m) optimum EMI/RFI protected cable |
| Accuracy | Depends on the accuracy of the chemical test used to calibrate the sensor |
| Condition | New & Original in Factory Packing |
| Factory Warranty | 12 Months |
Description
The 499AOZ-54-03CC is an Emerson Rosemount Analytical 499AOZ dissolved ozone sensor supplied new and original in factory packing. Maintenance and instrumentation teams choose this genuine unit when they need a verified sensor for ozone measurement rather than an unconfirmed substitute. Autronexa sources authentic automation components with clear condition reporting and practical lead times.
What This Dissolved Ozone Sensor Does
The 499AOZ family measures dissolved ozone in water treatment and process streams. This variant, the 499AOZ-54-03CC, is configured for transmitter compatibility with the Rosemount 1056, 1066-DO, 56, and 5081-A. Its body is molded from ozone-resistant polysulfone, which suits continuous contact with ozonated water. The membrane is easily replaceable without special tools, so routine service stays straightforward. Pressure equalization maintains correct membrane tension in pressurized samples, and automatic compensation adjusts for changes in membrane permeability. The integral 33-ft. (10 m) cable is specified as optimum EMI/RFI protected, which helps in electrically noisy plant environments. Ambient temperature range is 32 to 122 °F (0 to 50 °C).

How This Sensor Compares With Other Ozone Measurement Options
Buyers often weigh This unit against other dissolved ozone sensors or against generic replacements. The comparison below reflects only the data available for this model.
- Membrane service: Easily replaceable membrane, no special tools required.
- Pressurized samples: Pressure equalization maintains correct membrane tension.
- Permeability drift: Automatic compensation for changes in membrane permeability.
- Cable replacement: Variopol connector option allows sensor replacement without running new cable.
- Calibration accuracy: Accuracy depends on the accuracy of the chemical test used to calibrate the sensor.

Sourcing This Sensor Through Autronexa
This unit is listed as new and original in factory packing with a 12-month factory warranty. Autronexa verifies condition and part-number markings before dispatch, so you know what arrives. For current availability and lead time, contact Autronexa with your part number. Genuine parts, verified.
Frequently asked questions
Is the 499AOZ-54-03CC a genuine Emerson Rosemount sensor?
Yes. Autronexa verifies units against OEM datasheet markings and part-number cross-reference before dispatch. This listing is for a new and original unit in factory packing.
What condition will the 499AOZ-54-03CC arrive in?
The unit is supplied new and original in factory packing, with a 12-month factory warranty stated in the source data.
How fast can Autronexa ship the 499AOZ-54-03CC?
Contact Autronexa for current lead time and availability. Lead time is confirmed per order so you can plan maintenance windows.
Which transmitters is the 499AOZ-54-03CC compatible with?
The 54 ordering code indicates compatibility with Rosemount 1056, 1066-DO, 56, and 5081-A transmitters.
Related & compatible parts
Emerson
EZ1080-18-08-010
Genuine surplus Emerson EZ1080-18-08-010 8mm eddy current sensor, verified and ready to ship for turbomachinery displacement measurement.
Emerson
EMERSON 191736-01
Genuine surplus Emerson 191736-01 rotary encoder, 5 VDC flange mount with 10-pin connection. Verified condition and practical sourcing…
Emerson
A6210
Genuine surplus Emerson A6210 monitor for thrust, differential expansion, and rod position — verified condition with clear lead…
Emerson
EZ1080-12-00-010
Genuine surplus Emerson EZ1080-12-00-010 8mm eddy current sensor with M10x1 threads and 1m cable, verified for turbomachinery displacement…
News & guides for Emerson
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…