| Supply Voltage | 5 VDC |
|---|---|
| Mounting | Flange mount |
| Connection | 10 pin |
| Mechanical Contact Voltage Rating | 24 V AC/DC |
| Mechanical Contact Breaking Capacity | 0.5 A / max. 1 A |
| Inductive Contact Voltage Rating | 10 to 30 V DC |
| Inductive Contact Current | 100 mA |
| Degree of Protection | IP66 (EN 60529) |
| Ambient Temperature Range | -20°C to +80°C (mechanical); -20°C to +70°C (inductive) |
| Safety Rating | SIL2 capable - IEC 61508:2010 |
Description
The EMERSON 191736-01 is a flange-mount rotary encoder rated at 5 VDC with a 10-pin connection, used to signal valve end-of-travel positions. For maintenance and procurement teams, a verified genuine surplus unit keeps critical valve feedback loops running without the wait of a full OEM order. Autronexa supplies this encoder as tested surplus or refurbished stock, with condition confirmed before dispatch.
What the 191736-01 Does in a Valve Control Loop
At both end-of-travel positions of the valve stem, cams on the signaling box plunger operate contacts that provide an electrical signal confirming the end position is reached. The 191736-01 therefore acts as the feedback element that tells your control system whether a valve is fully open or fully closed. Its flange-mount body and 10-pin interface suit direct replacement in the SCS-2/SDC50-2-7 signaling arrangement, so engineers can restore position feedback without reworking the mounting. Because the encoder is a mechanical signaling device, correct fit and contact condition matter more than cosmetic appearance.

Key Electrical and Environmental Ratings
The 191736-01 supports mechanical contacts rated at 24 V AC/DC with a breaking capacity of 0.5 A and a maximum of 1 A. Inductive PNP/NPN contacts operate from 10 to 30 V DC at 100 mA, with a maximum wattage rating of 0.95 W. The housing carries IP66 protection to EN 60529, and the ambient temperature range is -20°C to +80°C for mechanical contacts or -20°C to +70°C for inductive contacts. Vibration tolerance is 1 g to EN 60068-2-6. The unit is SIL2 capable to IEC 61508:2010, so it can support safety-related valve signaling when the surrounding system is engineered accordingly. These figures let you confirm the encoder matches your panel voltage and contact type before ordering.

Why Genuine Surplus Fits This Encoder
Valve signaling components are often replaced on short notice, and OEM lead times can stall a planned outage. Autronexa holds genuine surplus and refurbished Emerson units, each checked against OEM datasheet markings and functionally verified by our sourcing team. That approach gives you a practical alternative to full list price while keeping the part authentic. For the 191736-01, confirm the contact type your circuit uses, since mechanical and inductive variants carry different voltage and temperature limits. Share your exact model and application details, and our team will confirm condition, test status, and current availability before you commit.
Frequently asked questions
Is the EMERSON 191736-01 a genuine Emerson part or a clone?
Autronexa supplies genuine surplus and refurbished Emerson units. Each 191736-01 is checked against OEM datasheet markings and part-number cross-references before it is listed.
What condition will the 191736-01 arrive in?
Units are supplied as refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the current condition grade of available stock.
How fast can Autronexa ship the 191736-01?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability before placing your order.
Does the 191736-01 suit both mechanical and inductive contact circuits?
The 191736-01 supports mechanical contacts rated 24 V AC/DC and inductive PNP/NPN contacts rated 10 to 30 V DC. Confirm which contact type your circuit uses, as temperature limits differ between the two.
Related & compatible parts
Emerson
A6125
Genuine surplus Emerson A6125 two-channel vibration monitor module for CSI 6500 systems, verified and ready to ship from…
Emerson
499AOZ-54-03CC
Genuine Emerson Rosemount 499AOZ-54-03CC dissolved ozone sensor, new in factory packing with 12-month warranty, available through Autronexa's verified…
Emerson
A6220
Genuine surplus Emerson A6220 four-channel process input monitor for CSI 6500. Verified condition and practical sourcing support from…
Emerson
EZ1080-18-08-010
Genuine surplus Emerson EZ1080-18-08-010 8mm eddy current sensor, verified and ready to ship for turbomachinery displacement measurement.
News & guides for Emerson
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…