Lenze E82CV552K2C
Replaced by a bare metal cooling plate connected to a separate customer-side
Genuine surplus Lenze E82CV552K2C cold-plate inverter, 5.5 kW and 22.5 A nominal, verified and ready to ship for hard-to-source 8200 vector systems.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated motor power | 5.5 kW typical (4-pole three-phase asynchronous motor) |
|---|---|
| Rated output current | 22.5 A nominal at 8 kHz switching frequency |
| Max. output current | 33.8 A for 60 s (periodic load cycle: 1 min overload at Imax / 2 min base load at 75% Ir) |
| Supply voltage | 3/PE AC 100 V -0% … 264 V +0%; 45 … 65 Hz |
| Operating temperature | -10 … +55 °C (derated by 2.5%/°C above +40 °C) |
| Storage temperature | -25 … +60 °C |
| Relative humidity | Average 85 % RH, without condensation (climatic class 3K3 per EN 50178) |
| Protection rating | IP20 |
| Built-in ports | X3 control terminal strip (analog/digital I/O) |
| Communication expansion | FIF slot for plug-in function modules (E82ZAF* family) |
Description
How do you keep an 8200 vector drive running when the standard heatsink body no longer fits the enclosure? The Lenze E82CV552K2C answers that with cold-plate technology: a 5.5 kW frequency inverter whose heatsink is replaced by a bare metal cooling plate connected to a separate customer-side cooler. For maintenance and procurement teams supporting legacy Lenze systems, a genuine surplus or refurbished unit is often the practical route to keeping production moving.
What the Cold-Plate Design Changes
The E82CV552K2C belongs to the Lenze 8200 vector series, a family widely used for V/f and sensorless vector control of three-phase asynchronous motors. In this special design, heat leaves the drive through the cooling plate rather than a finned heatsink. The published thermal data is specific: dissipated power loss is 205 W, thermal resistance between cooler and cooling medium is Rth ≤ 0.13 K/W, and the maximum permissible cooling-plate temperature is 75 °C. Because the customer-side cooler becomes part of the thermal path, the plate mounting and coolant circuit deserve attention during installation and service.

Key Ratings at a Glance
| Parameter | Value |
|---|---|
| Rated motor power | 5.5 kW typical (4-pole three-phase asynchronous motor) |
| Rated output current | 22.5 A nominal at 8 kHz switching frequency |
| Max. output current | 33.8 A for 60 s |
| Supply voltage | 3/PE AC 100 V -0% … 264 V +0%; 45 … 65 Hz |
| Operating temperature | -10 … +55 °C (derated by 2.5%/°C above +40 °C) |
| Protection rating | IP20 |
Control covers V/f characteristic control (linear/quadratic) and sensorless vector control, with an output frequency range of -650 … +650 Hz. An integrated brake transistor and the X3 control terminal strip provide 1 analog input, 1 analog output, 4 digital inputs, 1 digital output and 1 relay output with a changeover contact rated 250 V AC / 3 A. No fieldbus protocol is built in; networking requires a plug-in function module in the FIF slot, part of the E82ZAF* family.

Why Genuine Surplus Fits This Model
Lenze lists the 8200 vector among its previous products, and the cold-plate special design is available on request. There is no drop-in same-order-code replacement, although Lenze documents a migration path to the i950. For operators who are not ready to migrate, sourcing a verified surplus or refurbished unit can bridge the gap. Each unit is checked against OEM datasheet markings and functionally verified by our sourcing team before dispatch. That approach gives you genuine parts, verified, without waiting on a special-design order. Surplus and refurbished, ready to ship when your maintenance window opens.
Sourcing Checklist Before You Order
Confirm the exact model code and the cold-plate configuration, since the standard E82EV body is not interchangeable. Check that your customer-side cooler can hold the plate below the 75 °C limit and that the Rth ≤ 0.13 K/W figure suits your cooling medium. Review the ambient range against your cabinet conditions, remembering the 2.5%/°C derating above +40 °C. Finally, decide whether a fieldbus module from the E82ZAF* family is needed for your network. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Lenze E82CV552K2C, or a clone?
Autronexa verifies units against OEM datasheet markings and part-number cross-reference before listing. The E82CV552K2C is supplied as a genuine Lenze surplus or refurbished unit, not a copy.
What condition will the E82CV552K2C arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the current condition grading of available units.
How fast can you ship the E82CV552K2C?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability, and we will confirm the shipping window.
Does the E82CV552K2C need a separate cooler to operate?
Yes. In this cold-plate design the heatsink is replaced by a bare metal cooling plate connected to a separate customer-side cooler. The maximum permissible cooling-plate temperature is 75 °C, with thermal resistance Rth ≤ 0.13 K/W.
Is the Lenze 8200 vector still supported by Lenze?
Lenze lists the 8200 vector among its previous products, and the cold-plate special design is available on request. Lenze documents a migration path to the i950, but there is no drop-in same-order-code replacement. Contact Autronexa to verify OEM support status.
Related & compatible parts
Lenze
E82CV302K4C
Genuine surplus Lenze E82CV302K4C 8200 vector inverter with cold-plate cooling, 3.0 kW rating and 7.3 A output —…
Lenze
E94AMHE0244
Genuine surplus Lenze E94AMHE0244 axis module, 11 kW, CANopen, DC-bus mounting. Verified condition and practical sourcing support from…
Lenze
E82CV251K2C
Genuine surplus Lenze E82CV251K2C cold-plate inverter: 0.25 kW, 1.7 A, IP20. Verified condition and practical sourcing support from…
Lenze
E94ASHE0074
Genuine surplus Lenze E94ASHE0074 axis module, 3 kW, CANopen on board. Verified condition and practical sourcing support from…
News & guides for Lenze
Lenze spare parts: buying guide, series overview and how to order
Lenze spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…