Honeywell 51202329-722
Cable assembly
Genuine Honeywell 51202329-722 36-inch gray I/O Link extension cable for Experion PKS Series C. Verified surplus and refurbished units from Autronexa.
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
Technical specifications
| Cable family | Series C I/O Link (IOL1), 750 KBaud |
|---|---|
| Cable length | 36 inches (1000 mm) |
| Jacket color | Gray |
| Redundancy variant | Cable pair (one Cable A yellow + one Cable B green) |
| Built-in ports | None (passive pre-terminated cable) |
| Maximum extension length | 30 ft (9 m) per grounding rules |
| I/O Links per C300 Controller | 2 (IOL1 + IOL2) |
Description
The Honeywell 51202329-722 is a Cable assembly for industrial control and automation applications.
The Honeywell 51202329-722 is a 36-inch (1000 mm) gray pre-terminated I/O Link extension cable assembly for Experion PKS Series C C300 Controller IOTA cabling. Maintenance and procurement teams choose genuine surplus or refurbished units of this passive cable to restore I/O Link runs without waiting on OEM lead times.
What this unit Does in a Series C Cabinet
This cable assembly extends the Series C I/O Link (IOL1) past areas with no IOTA connections or to another cabinet side. It carries the 750 KBaud I/O Link signaling between the C300 Controller IOTA ports (IOL1A/B or IOL2A/B) and Series C IOTAs or IOMs. Because it is passive with no built-in ports, it simply plugs into the IOTA and IOTA drop connectors. The gray jacket identifies the IOL1 link, and the assembly is available as a single cable or as a redundant pair with one yellow Cable A and one green Cable B. Both cables are always required as a pair for redundancy. Per Honeywell grounding rules, extension cable length must not exceed 30 ft (9 m).

Surplus Advantage: Why a Verified Cable Beats a Long OEM Wait
Cable assemblies are easy to overlook until a link goes down. A failed or missing this unit can stall a cabinet build or a controller upgrade, and OEM spare channels often add weeks. Autronexa stocks genuine surplus and refurbished Honeywell cable assemblies, each inspected and functionally verified before dispatch. You get a practical alternative to full OEM list price with clear lead times. The Series C platform remains active in Honeywell documentation, so sourcing a verified cable keeps existing cabinets serviceable without redesign.

How This Cable Compares with Other Sourcing Options
- Genuine surplus or refurbished (Autronexa): verified Honeywell assembly, tested condition, faster availability than factory order.
- New from OEM: guaranteed current build, but longer lead time and higher list price.
- Third-party distributor listings: often show contradictory specs (connector type, temperature range, cable length) that do not match Honeywell documentation.
- Generic cable substitutes: no guarantee of 750 KBaud link performance or correct IOL1/IOL2 color coding.
Selection and Sourcing Checks
Confirm you need the 36-inch (1000 mm) extension length rather than a shorter drop cable. Verify whether your cabinet uses IOL1 (gray) or IOL2 (violet) coding, and order Cable A and Cable B together if redundancy is required. Ask for the exact model this unit and state whether you need a single cable or a pair. Autronexa can cross-check your IOTA port labels against the cable color coding before shipping. Share your part number with Autronexa and we will confirm verified condition and current availability.
Frequently asked questions
Is the Honeywell 51202329-722 a genuine part or a clone?
Autronexa supplies genuine Honeywell 51202329-722 cable assemblies sourced as surplus or professionally refurbished units. Each cable is checked against OEM markings and the published Series C cable part number before it is listed.
What condition will the 51202329-722 cable arrive in?
The Honeywell 51202329-722 is supplied in verified surplus or refurbished condition, tested for continuity and link integrity. Contact Autronexa for the specific condition grade of the unit in stock.
How long is the 51202329-722 cable and how far can it extend an I/O Link?
The Honeywell 51202329-722 is a 36-inch (1000 mm) pre-terminated extension cable. Honeywell grounding rules limit total extension cable length to 30 ft (9 m).
Does the 51202329-722 work with both IOL1 and IOL2 ports?
The Honeywell 51202329-722 has a gray jacket for the IOL1 link. For IOL2, Honeywell uses violet coding, so confirm your port label and cable color before ordering.
How fast can Autronexa ship the 51202329-722?
Lead time depends on current verified stock of the Honeywell 51202329-722. Contact Autronexa with your required quantity and we will confirm availability and dispatch timing.
Related & compatible parts
Honeywell
900G03-0202
Genuine surplus Honeywell 900G03-0202 digital input module with 16 sinking inputs and 80–264 VAC range, verified and ready…
Honeywell
TC-PIL081
Honeywell TC-PIL081 Vibration Monitoring. L/ Range: Not presently supported; Inches: 3.0 x 3.7 x 1.8. New surplus stock,…
Honeywell
2MLF-AD16A
Genuine surplus Honeywell 2MLF-AD16A analog input module with 16 channels and 500μs/channel conversion, verified and ready to ship.
Honeywell
10302/2/1
Genuine surplus Honeywell 10302/2/1 watchdog repeater, verified and ready to ship for multiple-PSU configurations.
News & guides for Honeywell
Honeywell spare parts: buying guide, series overview and how to order
Honeywell spare parts buying guide: 3 parts online, popular series, condition options and how our RFQ process works.
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…