Honeywell I/O & Function Modules

Honeywell 900G03-0202

Digital Input 120/240 VAC

Manufacturer: Honeywell Part Number: 900G03-0202

Genuine surplus Honeywell 900G03-0202 digital input module with 16 sinking inputs and 80–264 VAC range, verified and ready to ship.

Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

Technical specifications

Inputs per module 16 (sinking)
Input Voltage Range 80 VAC to 264 VAC
Peak Voltage 264 VAC
AC Frequency 47 Hz to 63 Hz
Galvanic Isolation 2 groups of 8 inputs (350 VAC max.)
ON Voltage Level 75 VAC
OFF Voltage Level 20 VAC
Input Impedance 48 K ohms nominal
Input Current 1 mA nominal @ 120 VAC, 60 Hz; 2 mA nominal @ 230 VAC, 50 Hz
Response Time OFF to ON: 4 ms + 1.5-line cycles max.; ON to OFF: 4 ms + 2-line cycles max.

Description

The Honeywell 900G03-0202 is a Digital Input 120/240 VAC for industrial control and automation applications.

The Honeywell 900G03-0202 is a 16-point AC digital input module for 120/240 VAC systems, offering an 80 VAC to 264 VAC input range and 2 groups of 8 inputs with galvanic isolation. Maintenance teams choose genuine surplus or refurbished units to restore input integrity quickly without waiting on OEM lead times.

What Does this unit Do in a Control Cabinet?

This unit accepts externally powered AC signals and converts them into logic states for the controller. Each input turns ON when AC power is applied between the common terminal and the input. Two common terminals are provided for each circuit, simplifying field wiring for eight inputs per group. A green LED per channel shows the ON state, so technicians can confirm signal presence at a glance. The module also supports logic inversion in the controller when necessary, giving engineers flexibility during commissioning or troubleshooting.

Figure 1: Front view of the Honeywell 900G03-0202 Digital Input 120/240 VAC showing its physical design and enclosure.

How Do the Isolation and Voltage Ratings Support Reliable Service?

Galvanic isolation splits the module into two groups of eight inputs, each rated to 350 VAC maximum. This separation helps contain faults and reduces noise coupling between field circuits. The wide 80 VAC to 264 VAC input range covers both 120 VAC and 240 VAC systems, while the 47 Hz to 63 Hz frequency band suits standard industrial supplies. With a nominal input impedance of 48 K ohms and a nominal input current of 1 mA at 120 VAC, 60 Hz (2 mA at 230 VAC, 50 Hz), the module presents a predictable load to field devices. The ON voltage level is 75 VAC and the OFF voltage level is 20 VAC, giving clear thresholds for reliable state detection.

Figure 2: Technical layout and connection details for the Honeywell 900G03-0202 Digital Input 120/240 VAC.

Why Choose Genuine Surplus for this unit?

When a digital input module fails, every hour of downtime adds pressure to maintenance and production schedules. Autronexa supplies genuine surplus and refurbished Honeywell this unit units that are verified against OEM datasheet specifications and functionally tested by our sourcing team. This approach gives you a practical alternative to OEM lead times while keeping the input architecture of your existing system intact. Our team understands this unit’s role in AC input subsystems and can help you confirm the exact configuration you need. Surplus and refurbished, ready to ship, with clear condition notes and lead times provided before you commit.

What Should Maintenance Engineers Verify Before Installing?

Before ordering, confirm the input voltage of your field circuits falls within the 80 VAC to 264 VAC range and that your wiring plan matches the two groups of eight inputs. Check that the common terminals are available for each circuit and that the 350 VAC isolation rating meets your panel requirements. Review the response times: OFF to ON is 4 ms plus 1.5-line cycles maximum, and ON to OFF is 4 ms plus 2-line cycles maximum. These figures help you assess compatibility with your controller scan time. Also verify the module’s diagnostic indicators: a green blinking status LED indicates the module is being scanned, and a red status LED indicates module diagnostics exist. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is the Honeywell 900G03-0202 a genuine module or a clone?

Autronexa verifies each 900G03-0202 against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished units, not grey-market clones.

What condition will the 900G03-0202 arrive in?

The 900G03-0202 is supplied as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Condition notes are provided before purchase.

How fast can Autronexa ship the 900G03-0202?

Lead time for the 900G03-0202 depends on current stock. Contact Autronexa for current availability and lead time before placing your order.

Does the 900G03-0202 support both 120 VAC and 240 VAC systems?

Yes, the 900G03-0202 has an input voltage range of 80 VAC to 264 VAC, covering both 120 VAC and 240 VAC circuits, with a frequency range of 47 Hz to 63 Hz.

Related & compatible parts

Honeywell

2108B2101N

Genuine Honeywell 2108B2101N Optima Plus hydrocarbon gas detector, surplus and refurbished, with 0-100% LEL range and 4-20 mA…

In Stock

Honeywell

900H03-0202

Genuine surplus Honeywell 900H03-0202 digital output module with 8 isolated Triac outputs, verified condition and clear lead times…

Quote on request

Honeywell

TC-PIL081

Honeywell TC-PIL081 Vibration Monitoring. L/ Range: Not presently supported; Inches: 3.0 x 3.7 x 1.8. New surplus stock,…

Available on request

Honeywell

MLE-TN32A

Genuine surplus Honeywell MLE-TN32A digital output module with 32 open collector channels, verified condition and practical sourcing support…

Quote on request

News & guides for Honeywell

View all articles

Request a quote for this part

Part number: 900G03-0202

We reply within one business day.

900G03-0202 Quote reply within 1 business day