Honeywell I/O & Function Modules
Honeywell 900B08-0202
Analog Outputs 0 to 20mA
Genuine surplus Honeywell 900B08-0202 analog output module with eight 0–21 mA channels, group isolation, and failsafe support — verified and ready to source.
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
Technical specifications
| Outputs per module | 8, isolated in 2 groups of 4 outputs (1-4, 5-8) |
|---|---|
| Current range | 0 to 21.0 mA range selectable |
| Load resistance | 750 ohms max |
| Galvanic isolation | 500 VDC group to group; 500 VDC from logic |
| Accuracy | 0.1% full scale at reference conditions |
| D/A resolution | 13+ bits (1 part in 13332) |
| Modules per rack | 5 max internal 24V backplane; 10 max external 24V backplane |
| Terminal block | Euro style 36-terminal terminal block required |
Description
The Honeywell 900B08-0202 is a Analog Outputs 0 to 20mA for industrial control and automation applications.
When a control loop needs eight independent current outputs but the cabinet is already crowded, engineers often face a choice between extra hardware and compromised signal integrity. The Honeywell 900B08-0202 analog output module solves that problem directly: eight 0 to 21.0 mA outputs, each user-scalable to any span within that range, all isolated from controller logic. Autronexa supplies this module as genuine surplus and refurbished stock, verified against OEM datasheet markings before dispatch.
What this unit Delivers in a Control Cabinet
The module provides eight outputs isolated in two groups of four (channels 1–4 and 5–8). Group-to-group galvanic isolation is rated 500 VDC, and each group is also isolated from logic at 500 VDC. That arrangement lets a single module drive field devices in different signal-reference zones without adding separate isolators. Accuracy is 0.1% of full scale at reference conditions, with a maximum load resistance of 750 ohms. A 13+ bit D/A resolution (1 part in 13332) supports fine current steps for span-scaled loops. Outputs update synchronously with control execution, and a user-specified slew rate limit can be applied per output through the slew rate function block. A Euro-style 36-terminal terminal block is required for wiring.

Diagnostics, Failsafe Behaviour, and Rack Capacity
A green blinking status LED shows when the module is being scanned; a red LED indicates module or channel diagnostics. Calibration data lives in non-volatile memory with redundant factory calibration and automatic rejection of a bad version. Diagnostics cover factory calibration, configuration, and the +24 VDC supply, while output verification feeds current-flow status back to the controller. For failsafe behaviour, users can select hold-last-value or a specified failsafe value, so outputs move to a predictable state if communication with the controller is interrupted. Rack capacity depends on backplane power: up to 5 modules per rack on internal 24 VDC, or up to 10 modules when powered from an external 24 VDC backplane supply.

Why Genuine Surplus Fits This Module
For a module with redundant calibration memory and group isolation, authenticity matters more than cosmetics. Autronexa verifies each this unit against OEM datasheet markings and part-number cross-reference, then functionally checks it before listing. Surplus and refurbished units give maintenance teams a practical alternative to waiting on OEM lead times, especially when a single failed output card is holding up a running process. Every unit is genuine parts, verified, and surplus and refurbished, ready to ship once condition and availability are confirmed. Share your part number with Autronexa and we will confirm verified condition and current availability.
Frequently asked questions
Is the Honeywell 900B08-0202 a genuine module or a clone?
Autronexa verifies each 900B08-0202 against OEM datasheet markings and part-number cross-reference before listing it. Units are sourced as genuine surplus or professionally refurbished stock, not grey-market copies.
What condition will the 900B08-0202 arrive in?
The 900B08-0202 is supplied as refurbished stock by default. Each unit is functionally verified by our sourcing team, and condition details are confirmed with you before dispatch.
How many 900B08-0202 modules can share one rack?
The 900B08-0202 supports up to 5 modules per rack when powered from internal 24 VDC backplane power, or up to 10 modules per rack when an external 24 VDC backplane supply is used.
Does the 900B08-0202 support failsafe output states?
Yes. The 900B08-0202 offers a user-specified failsafe value and a hold-last-value option, so outputs behave predictably if communication between the module and controller is interrupted.
Related & compatible parts
Honeywell
2108B2101N
Genuine Honeywell 2108B2101N Optima Plus hydrocarbon gas detector, surplus and refurbished, with 0-100% LEL range and 4-20 mA…
Honeywell
2MLF-AV8A
Genuine surplus Honeywell 2MLF-AV8A analog input module with 8 channels for MasterLogic ML200 PLC systems, verified and ready…
Honeywell
2MLF-DC8A
Genuine surplus Honeywell 2MLF-DC8A analog output module with 8 current channels and selectable DC 4~20mA or DC 0~20mA…
Honeywell
2MLF-AD4S
Genuine surplus Honeywell 2MLF-AD4S analog I/O module with 4 isolated input channels, verified and ready for MasterLogic ML200…
News & guides for Honeywell
Honeywell spare parts: buying guide, series overview and how to order
Honeywell spare parts buying guide: 3 parts online, popular series, condition options and how our RFQ process works.
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…