Technical specifications

Outputs per module 8, isolated in 2 groups of 4 outputs (1-4, 5-8)
Current range 0 to 21.0 mA range selectable
Load resistance 750 ohms max
Galvanic isolation 500 VDC group to group; 500 VDC from logic
Accuracy 0.1% full scale at reference conditions
D/A resolution 13+ bits (1 part in 13332)
Modules per rack 5 max internal 24V backplane; 10 max external 24V backplane
Terminal block Euro style 36-terminal terminal block required

Description

The Honeywell 900B08-0202 is a Analog Outputs 0 to 20mA for industrial control and automation applications.

When a control loop needs eight independent current outputs but the cabinet is already crowded, engineers often face a choice between extra hardware and compromised signal integrity. The Honeywell 900B08-0202 analog output module solves that problem directly: eight 0 to 21.0 mA outputs, each user-scalable to any span within that range, all isolated from controller logic. Autronexa supplies this module as genuine surplus and refurbished stock, verified against OEM datasheet markings before dispatch.

What this unit Delivers in a Control Cabinet

The module provides eight outputs isolated in two groups of four (channels 1–4 and 5–8). Group-to-group galvanic isolation is rated 500 VDC, and each group is also isolated from logic at 500 VDC. That arrangement lets a single module drive field devices in different signal-reference zones without adding separate isolators. Accuracy is 0.1% of full scale at reference conditions, with a maximum load resistance of 750 ohms. A 13+ bit D/A resolution (1 part in 13332) supports fine current steps for span-scaled loops. Outputs update synchronously with control execution, and a user-specified slew rate limit can be applied per output through the slew rate function block. A Euro-style 36-terminal terminal block is required for wiring.

Figure 1: Front view of the Honeywell 900B08-0202 Analog Outputs 0 to 20mA showing its physical design and enclosure.

Diagnostics, Failsafe Behaviour, and Rack Capacity

A green blinking status LED shows when the module is being scanned; a red LED indicates module or channel diagnostics. Calibration data lives in non-volatile memory with redundant factory calibration and automatic rejection of a bad version. Diagnostics cover factory calibration, configuration, and the +24 VDC supply, while output verification feeds current-flow status back to the controller. For failsafe behaviour, users can select hold-last-value or a specified failsafe value, so outputs move to a predictable state if communication with the controller is interrupted. Rack capacity depends on backplane power: up to 5 modules per rack on internal 24 VDC, or up to 10 modules when powered from an external 24 VDC backplane supply.

Figure 2: Technical layout and connection details for the Honeywell 900B08-0202 Analog Outputs 0 to 20mA.

Why Genuine Surplus Fits This Module

For a module with redundant calibration memory and group isolation, authenticity matters more than cosmetics. Autronexa verifies each this unit against OEM datasheet markings and part-number cross-reference, then functionally checks it before listing. Surplus and refurbished units give maintenance teams a practical alternative to waiting on OEM lead times, especially when a single failed output card is holding up a running process. Every unit is genuine parts, verified, and surplus and refurbished, ready to ship once condition and availability are confirmed. Share your part number with Autronexa and we will confirm verified condition and current availability.

Frequently asked questions

Is the Honeywell 900B08-0202 a genuine module or a clone?

Autronexa verifies each 900B08-0202 against OEM datasheet markings and part-number cross-reference before listing it. Units are sourced as genuine surplus or professionally refurbished stock, not grey-market copies.

What condition will the 900B08-0202 arrive in?

The 900B08-0202 is supplied as refurbished stock by default. Each unit is functionally verified by our sourcing team, and condition details are confirmed with you before dispatch.

How many 900B08-0202 modules can share one rack?

The 900B08-0202 supports up to 5 modules per rack when powered from internal 24 VDC backplane power, or up to 10 modules per rack when an external 24 VDC backplane supply is used.

Does the 900B08-0202 support failsafe output states?

Yes. The 900B08-0202 offers a user-specified failsafe value and a hold-last-value option, so outputs behave predictably if communication between the module and controller is interrupted.

Related & compatible parts

Honeywell

2108B2101N

Genuine Honeywell 2108B2101N Optima Plus hydrocarbon gas detector, surplus and refurbished, with 0-100% LEL range and 4-20 mA…

In Stock

Honeywell

2MLF-AV8A

Genuine surplus Honeywell 2MLF-AV8A analog input module with 8 channels for MasterLogic ML200 PLC systems, verified and ready…

In Stock

Honeywell

2MLF-DC8A

Genuine surplus Honeywell 2MLF-DC8A analog output module with 8 current channels and selectable DC 4~20mA or DC 0~20mA…

In Stock

Honeywell

2MLF-AD4S

Genuine surplus Honeywell 2MLF-AD4S analog I/O module with 4 isolated input channels, verified and ready for MasterLogic ML200…

In Stock

News & guides for Honeywell

View all articles

Request a quote for this part

Part number: 900B08-0202

We reply within one business day.

900B08-0202 Quote reply within 1 business day