Technical specifications

Inputs per module 16 (isolated)
Input types V, mA
Input impedance >1 megohm for volts and 250 ohms for mA inputs
Galvanic input isolation 400 VDC point to point; 1K VDC to logic
Accuracy ±0.1% of range (factory configured)
A/D resolution ±15 Bits
Update rate 100ms

Description

The Honeywell 900A16-0103 is a Analog Input High Level for industrial control and automation applications.

How do you add sixteen isolated analog inputs without stretching scan time or risking signal integrity? The Honeywell 900A16-0103 high-level analog input module answers that question with point-to-point isolation and parallel processing. Autronexa supplies this genuine surplus module with verified condition and practical sourcing support for maintenance and controls teams.

What the Honeywell this unit Delivers in a Control System

this unit is a 16-channel analog input module for Honeywell control systems. Each input is user-configurable per point for voltage or current, so one module covers mixed signal types. Point-to-point isolation and backplane isolation are provided, with galvanic input isolation rated 400 VDC point to point and 1K VDC to logic. A green blinking status LED indicates when the module is being scanned, while a red LED signals module or channel diagnostics. This visible status helps technicians confirm operation during routine checks. The module stores calibration and channel configuration data in non-volatile memory, which supports consistent behavior after power cycles.

Figure 1: Front view of the Honeywell 900A16-0103 Analog Input High Level showing its physical design and enclosure.

Technical Specs That Matter on the Plant Floor

this unit provides 16 isolated inputs with input impedance greater than 1 megohm for volts and 250 ohms for mA inputs. Factory-configured accuracy is ±0.1% of range under reference conditions of 25 °C ± 3 °C and 45% to 55% RH non-condensing. Temperature effect on accuracy is ±0.01% of full scale per degree Celsius maximum. Noise rejection is greater than 31dB in series mode and greater than 90dB common mode at 120VAC. The A/D converter offers ±15 bits resolution with an update rate of 100ms per module. Long-term stability is 0.1% per year. These figures help engineers judge whether the module suits low-level signal monitoring in demanding cabinets.

Figure 2: Technical layout and connection details for the Honeywell 900A16-0103 Analog Input High Level.

Why Genuine Surplus Makes Sense for This Module

OEM lead times for analog input modules can stall planned maintenance. Autronexa offers genuine surplus and refurbished Honeywell this unit units that are verified against OEM datasheet markings and functionally checked by our sourcing team. Because the module performs analog-to-digital conversion in synchronization with CPU control execution, replacing a faulty unit with a verified spare restores signal processing without data interchange latency. Our practical sourcing help covers Allen-Bradley, Bently Nevada, Siemens, Schneider and more, so you can consolidate spare-parts requests. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is the Honeywell 900A16-0103 a genuine module or a clone?

Autronexa verifies each Honeywell 900A16-0103 against OEM datasheet markings and part-number cross-reference before it enters stock. Units are genuine surplus or refurbished, not grey-market copies.

What condition will the 900A16-0103 arrive in?

The Honeywell 900A16-0103 is supplied in refurbished condition by default. Our team tests against OEM datasheet specifications and performs functional verification before dispatch.

How fast can Autronexa ship the 900A16-0103?

Lead time for the Honeywell 900A16-0103 depends on current stock. Contact Autronexa with your part number to confirm verified condition and current availability.

Does the 900A16-0103 support both voltage and current inputs?

Yes. The Honeywell 900A16-0103 supports up to 16 user-configurable inputs on a per-point basis for voltage or current signals, with input impedance greater than 1 megohm for volts and 250 ohms for mA inputs.

Related & compatible parts

Honeywell

CC-PCF901

Genuine surplus Honeywell CC-PCF901 Control Firewall Module for FTE cable distribution to Series C FIMs and C300 controllers.

In Stock

Honeywell

2MLI-CPUS

Genuine surplus Honeywell 2MLI-CPUS CPU for MasterLogic-200 Series Max, with 768 I/O points and 640KB program memory. Verified…

In Stock

Honeywell

2MLF-HO2A

Genuine surplus Honeywell 2MLF-HO2A high-speed counter module: 200 kHz, 2-channel, open-collector input. Verified condition and clear lead times…

In Stock

Honeywell

2108B2001N

Genuine Honeywell 2108B2001N Hydrocarbon Searchpoint Optima Plus ATEX detector — new in factory packing, verified with a 12-month…

In Stock

News & guides for Honeywell

View all articles

Request a quote for this part

Part number: 900A16-0103

We reply within one business day.

900A16-0103 Quote reply within 1 business day