FANUC Cables & Connectors FANUC System 3/5/6 CNC
FANUC A02B-0047-C902
Cable
Genuine surplus FANUC A02B-0047-C902 cooling fan unit for System 3/5/6 CNC cabinets, verified and ready to ship from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Function | Cooling fan unit for CNC cabinet ventilation |
|---|---|
| Series | FANUC System 3/5/6 CNC |
| Lifecycle | Legacy spare for early FANUC CNC generations |
| Weight | ~2.15 kg (supplier-reported, family-level reference) |
| Supply Voltage | Not published by manufacturer for this order code |
| Communication Interface | Not applicable (fan unit) |
Description
When a cabinet cooling fan fails on a running FANUC System 3/5/6 CNC, heat builds inside the enclosure and puts every board at risk. The A02B-0047-C902 is the FANUC cooling fan unit specified for that ventilation role, and sourcing a genuine unit quickly keeps the control reliable. Autronexa supplies this legacy part as verified surplus, so maintenance teams can restore airflow without waiting on a long OEM channel.
What the A02B-0047-C902 Does in a FANUC CNC Cabinet
This unit is a cooling fan unit built for FANUC System 3/5/6 CNC cabinet ventilation. Its job is straightforward: move air through the enclosure so heat from drives and control boards does not accumulate. Because the part belongs to the early FANUC CNC generations, it is now a legacy spare rather than a current-production item. That makes condition and authenticity the two things a maintenance engineer should check first. The unit is a passive component with no fieldbus or network interface, so replacement is a mechanical and electrical fit question, not a configuration task. In practice, that means service work stays simple: isolate the cabinet, confirm the mounting and connector arrangement, and swap the unit.

Why Genuine Surplus Fits This Legacy Fan Unit
FANUC lists this fan unit as a spare for early CNC generations, and it appears in aftermarket channels rather than as a standard catalog line. For a plant keeping System 3/5/6 machines in service, that changes the sourcing calculation. A genuine surplus unit avoids the uncertainty of an unbranded copy, while refurbished stock gives a tested alternative when new supply is not practical. Autronexa verifies units against OEM datasheet markings and part-number cross-reference before they enter stock. Each unit is functionally checked by the sourcing team, and condition is stated clearly before you commit. For a fan unit, that verification matters because airflow and bearing condition are not visible from the outside. Genuine parts, verified — that is the standard we apply to legacy FANUC spares like this one.

Sourcing Checklist for This unit
Before ordering, confirm the exact order code on the existing unit and compare it with unit. Check the cabinet mounting arrangement and the connector type on the failed fan, since these details decide whether a replacement drops in cleanly. Ask for the condition grade — surplus or refurbished — and request the verification details for the specific unit offered. Note that FANUC does not publish a rated supply voltage for this order code, so the cabinet wiring and the original unit’s label are the practical references. Weight is supplier-reported at approximately 2.15 kg at family level, so treat it as a shipping guide rather than a confirmed figure for every unit. Because this is a legacy part, please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine FANUC A02B-0047-C902, or a copy?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it is listed. The A02B-0047-C902 is supplied as genuine surplus or refurbished stock, and the verification details are available on request.
What condition will the A02B-0047-C902 arrive in?
Units are supplied as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available, and the condition grade is confirmed before you order.
How fast can you ship the A02B-0047-C902?
Lead time depends on current stock for this legacy FANUC fan unit. Contact Autronexa for current lead time and availability before placing your order.
Does this fan unit suit FANUC System 3/5/6 CNC cabinets?
Yes. The A02B-0047-C902 is a cooling fan unit for FANUC System 3/5/6 CNC cabinet ventilation. It has no fieldbus or network interface, so replacement is a mechanical and electrical fit task rather than a configuration step.
Is the A02B-0047-C902 still supported by FANUC?
The part is listed as a legacy spare for early FANUC CNC generations and appears in aftermarket channels. Contact Autronexa to verify OEM support status and current availability for your machine.
Related & compatible parts
FANUC · FANUC System 3/5/6 CNC
A02B-0047-C062
Genuine FANUC A02B-0047-C062 BTR cable for System 3/5/6 CNC, without reel. Verified surplus and refurbished units from Autronexa.
FANUC
A02B-0030-C004
Genuine surplus FANUC A02B-0030-C004 MDI keypad panel for Series 5 CNC controls, verified and available through Autronexa.
FANUC · FANUC System 3/5/6 CNC
A02B-0047-C311
Genuine surplus FANUC A02B-0047-C311 HMI option unit for System 3/5/6 CNC, verified and ready to ship from Autronexa.
FANUC
A02B-0050-C032
Genuine surplus FANUC A02B-0050-C032 9-inch monochrome CRT/MDI unit for System 6T CNC, verified and available through Autronexa.
News & guides for FANUC
FANUC CRX-3iA and P-55/15-21A at FABTECH 2026: What Maintenance Teams Should Stock
In short: FANUC America put two new machines on the FABTECH 2026 floor — the 11 kg CRX-3iA collaborative robot…
FANUC spare parts: buying guide, series overview and how to order
FANUC spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
