Manufacturer: Bently Nevada Part Number: 3500/42-06-01

Bently Nevada 3500/42-06-01 Proximitor Seismic Monitor. Transducer Type: Velomitor on channels 1 through 4; Output Impedance: 550 Ω.

  • Available on request
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

Technical specifications

Manufacturer Bently Nevada
Product No. 3500/42-06-01
Product type Proximitor Seismic Monitor
I/O Module Type 06
I/O Description I/O Module with internal barriers, internal terminations, 4 x Velomitor
Transducer Type Velomitor on channels 1 through 4
Hazardous Area Approval Option 01= CSA / NRTL / C (Class 1, Division 2)
Signal Accepts from 1 to 4 proximity, velocity or acceleration transducer signals
Power consumption 7.7 watts, typical
Standard I/O 10 kΩ (Proximitor and acceleration inputs)
Sensitivity Radial Vibration: 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil)
Thrust 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil)
Eccentricity 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil)
Differential Expansion 0.394 mV/μm (10 mV/mil) or 0.787 mV/μm (20 mV/mil) REBAM ; 40 mV/μm (1000 mV/mil) or 80 mV/μm (2000 mV/mil)
Acceleration & Acceleration2 10 mV/ (m/s2) (100 mV/g)
OK LED Indicates when the 3500/42M Proximitor Seismic Monitor is operating properly.
TX/RX LED Indicates when the 3500/42M Proximitor Seismic Monitor is communicating with other modules in the 3500 rack.
Bypass LED Indicates when the 3500/42M Proximitor Seismic Monitor is in Bypass Mode.
Buffered Transducer Outputs The front of each monitor has one coaxial connector for each channel.
Output Impedance 550 Ω
Transducer Power Supply -24 Vdc
Resolution 0.3662 µA per bit ±0.25% error at room temperature ±0.7% error over temperature range
Shaft Absolute Buffered Outputs The Shaft Absolute I/O modules have one output for each channel group.
Shaft Absolute Output Impedance 300 Ω
Signal Conditioning Specified at +25 ºC (+77 ºF) unless otherwise noted.
Direct filter User-programmable Single-pole -3db at 4 Hz to 4000 Hz or 1 Hz to 600 Hz ± 1% accuracy
Gap filter -3 dB at 0.09 Hz
Not 1X filter 60 cpm to 15.8 times running speed Constant Q notch filter Minimum rejection in stopband of -34.9 dB
Smax 0.125 to 15.8 times running speed 1X and 2X vector filter: Constant Q Filter Minimum rejection in stopband of -57.7 dB
Direct and Gap Exclusive of filtering Within ±0.33% of full-scale typical ±1% maximum 1X and 2X: Within ±0.33% of full-scale typical ±1% maximum
Smax Within ±5% maximum
Not 1X ±3% for machine speeds less than 30,000 cpm ±8.5% for machine speeds greater than 30,000 cpm
Accuracy Within ±0.33% of full-scale typical ±1% maximum
Direct filter -3 dB at 1.2 Hz
Gap filter -3 dB at 0.41 Hz
Direct filter -3 dB at 15.6 Hz
Accuracy Within ±0.33% of full-scale typical ±1% maximum Exclusive of filters
High-pass 4-pole (80 dB per decade, 24 dB per octave)
Low-pass 4-pole (80 dB per decade, 24 dB per octave)
Accuracy Within ± 0.33% of full scale typical ± 1% maximum Exclusive of filters
Bias filter -3 dB at 0.01 Hz
Not OK filter -3 dB at 2400 Hz 1X and 2X vector filter: Valid for machine speeds of 60 cpm to 100,000 cpm
Accuracy Within ±0.33% of full-scale typical ±1% maximum +1% -3% with MTL 764(-) Zener External Barrier Exclusive of filters Velomitor sensor accuracy:
Full Scale 0-0.5 ±3% typical
Full Scale 0-1.0 ±2% typical
Full Scale 0-2.0 ±1% typical
Velomitor sensor accuracy with barriers Under radiated immunity conditions, add ± 11% for all full scale ranges. The total Velomitor sensor accuracy will be ± 15%.
Bias -3dB at 0.01 Hz ; Velocity II only
Not OK filter -3 dB at 40 Hz; Velocity II only
RMS 10 to 5,500 Hz, -3 dB
Peak or peak to-peak 3 to 5,500 Hz, -3 dB 1X and 2X vector filter: Valid for machine speeds of 60 to 100,000 cpm Velocity II only
Low-pass 2-pole (40 dB per decade, 12 dB per octave)
Dimensions (Height x Widthx Depth) 241.3 mm x 24.4 mm x 241.8mm (9.50 in x 0.96 in x 9.52 in)

Description

The Bently Nevada 3500/42-06-01 is a proximitor seismic monitor for the 3500 Machinery Protection System. It conditions field transducer signals into vibration and position measurements and compares them against programmable alarm setpoints inside the 3500 rack. Dimensions are (height x widthx depth) 241.3 mm x 24.4 mm x 241.8mm (9.50 in x 0.96 in x 9.52 in) It monitors critical rotating equipment such as turbines, compressors, and pumps, and communicates monitor status and measured values to the 3500 rack and to recorder outputs for machinery protection. Configuration is performed with 3500 Rack Configuration Software; no field calibration is required.

Product Identification

  • Manufacturer: Bently Nevada.
  • Product No.: 3500/42-06-01.
  • Product type: Proximitor Seismic Monitor.

Ordering & Configuration

  • I/O Module Type: 06.
  • Hazardous Area Approval Option: 01= CSA / NRTL / C (Class 1, Division 2).

Electrical & Signal

  • Power consumption: 7.7 watts, typical.
  • Output Impedance: 550 Ω.
  • Resolution: 0.3662 µA per bit ±0.25% error at room temperature ±0.7% error over temperature range.
  • Shaft Absolute Output Impedance: 300 Ω.
  • Signal Conditioning: Specified at +25 ºC (+77 ºF) unless otherwise noted..
  • Accuracy: Within ±0.33% of full-scale typical ±1% maximum.
  • Accuracy: Within ±0.33% of full-scale typical ±1% maximum Exclusive of filters.
  • Accuracy: Within ± 0.33% of full scale typical ± 1% maximum Exclusive of filters.
  • Accuracy: Within ±0.33% of full-scale typical ±1% maximum +1% -3% with MTL 764(-) Zener External Barrier Exclusive of filters Velomitor sensor accuracy:.
  • Velomitor sensor accuracy with barriers: Under radiated immunity conditions, add ± 11% for all full scale ranges. The total Velomitor sensor accuracy will be ± 15%..

Physical & Mechanical

  • Dimensions: (Height x Widthx Depth) 241.3 mm x 24.4 mm x 241.8mm (9.50 in x 0.96 in x 9.52 in).

Specifications

  • I/O Description: I/O Module with internal barriers, internal terminations, 4 x Velomitor.
  • Transducer Type: Velomitor on channels 1 through 4.
  • Signal: Accepts from 1 to 4 proximity, velocity or acceleration transducer signals.
  • Standard I/O: 10 kΩ (Proximitor and acceleration inputs).
  • Sensitivity: Radial Vibration: 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil).
  • Thrust: 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil).
  • Eccentricity: 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil).
  • Differential Expansion: 0.394 mV/μm (10 mV/mil) or 0.787 mV/μm (20 mV/mil) REBAM ; 40 mV/μm (1000 mV/mil) or 80 mV/μm (2000 mV/mil).
  • Acceleration & Acceleration2: 10 mV/ (m/s2) (100 mV/g).
  • OK LED: Indicates when the 3500/42M Proximitor Seismic Monitor is operating properly..
  • TX/RX LED: Indicates when the 3500/42M Proximitor Seismic Monitor is communicating with other modules in the 3500 rack..
  • Bypass LED: Indicates when the 3500/42M Proximitor Seismic Monitor is in Bypass Mode..
  • Buffered Transducer Outputs: The front of each monitor has one coaxial connector for each channel..
  • Transducer Power Supply: -24 Vdc.
  • Shaft Absolute Buffered Outputs: The Shaft Absolute I/O modules have one output for each channel group..
  • Direct filter: User-programmable Single-pole -3db at 4 Hz to 4000 Hz or 1 Hz to 600 Hz ± 1% accuracy.
  • Gap filter: -3 dB at 0.09 Hz.
  • Not 1X filter: 60 cpm to 15.8 times running speed Constant Q notch filter Minimum rejection in stopband of -34.9 dB.
  • Smax: 0.125 to 15.8 times running speed 1X and 2X vector filter: Constant Q Filter Minimum rejection in stopband of -57.7 dB.
  • Direct and Gap: Exclusive of filtering Within ±0.33% of full-scale typical ±1% maximum 1X and 2X: Within ±0.33% of full-scale typical ±1% maximum.
  • Smax: Within ±5% maximum.
  • Not 1X: ±3% for machine speeds less than 30,000 cpm ±8.5% for machine speeds greater than 30,000 cpm.
  • Direct filter: -3 dB at 1.2 Hz.
  • Gap filter: -3 dB at 0.41 Hz.
  • Direct filter: -3 dB at 15.6 Hz.
  • High-pass: 4-pole (80 dB per decade, 24 dB per octave).
  • Low-pass: 4-pole (80 dB per decade, 24 dB per octave).
  • Bias filter: -3 dB at 0.01 Hz.
  • Not OK filter: -3 dB at 2400 Hz 1X and 2X vector filter: Valid for machine speeds of 60 cpm to 100,000 cpm.
  • Full Scale 0-0.5: ±3% typical.
  • Full Scale 0-1.0: ±2% typical.
  • Full Scale 0-2.0: ±1% typical.
  • Bias: -3dB at 0.01 Hz ; Velocity II only.
  • Not OK filter: -3 dB at 40 Hz; Velocity II only.
  • RMS: 10 to 5,500 Hz, -3 dB.
  • Peak or peak to-peak: 3 to 5,500 Hz, -3 dB 1X and 2X vector filter: Valid for machine speeds of 60 to 100,000 cpm Velocity II only.
  • Low-pass: 2-pole (40 dB per decade, 12 dB per octave).

Model Comparison

Compare the 3500/42-06-01 against the closest Bently Nevada configurations below to confirm ordering options, ratings and physical interchange.

Model Product No. Product type Direct filter Gap filter Accuracy High-pass Low-pass Dimensions
3500/42-06-01 3500/42-06-01 Proximitor Seismic Monitor -3 dB at 15.6 Hz -3 dB at 0.41 Hz Within ±0.33% of full-scale typical ±1% maximum +1% -3% with MTL 764(-) Zener External Barrier Exclusive of filters Velomitor sensor accuracy: 4-pole (80 dB per decade, 24 dB per octave) 2-pole (40 dB per decade, 12 dB per octave) (Height x Widthx Depth) 241.3 mm x 24.4 mm x 241.8mm (9.50 in x 0.96 in x 9.52 in)
3500/42-06-00 3500/42-06-00 Proximitor Seismic Monitor -3 dB at 15.6 Hz -3 dB at 0.41 Hz Within ±0.33% of full-scale typical ±1% maximum +1% -3% with MTL 764(-) Zener External Barrier Exclusive of filters Velomitor sensor accuracy: 4-pole (80 dB per decade, 24 dB per octave) 2-pole (40 dB per decade, 12 dB per octave) (Height x Widthx Depth) 241.3 mm x 24.4 mm x 241.8mm (9.50 in x 0.96 in x 9.52 in)
3500/42-02-01 3500/42-02-01 — — — — — — —
3500/42-01-02 3500/42-01-02 3500/42m Proximitor Seismic Monitor User-programmable 4 Hz to 4000 Hz or 1 Hz to 600 Hz -3 dB at 0.09 Hz 1X vector filter : Valid for machine speeds of 240 cpm to 60,000 cpm Within ±0.33% of full scale typical ±1% maximum Exclusive of filters 2-pole (40 dB per decade, 12 dB per octave) 2-pole (40 dB per decade, 12 dB per octave) 1X vector filter: Constant Q Filter Minimum rejection in stopband of -57.7 dB (Height x Widthx Depth) 241.3 mm x 24.4 mm x 163.1mm (9.50 in x 0.96 in x 6.42 in)
3500/42-02-00 3500/42-02-00 Proximitor Seismic Monitor -3 dB at 15.6 Hz -3 dB at 0.41 Hz Within ±0.33% of full-scale typical ±1% maximum +1% -3% with MTL 764(-) Zener External Barrier Exclusive of filters Velomitor sensor accuracy: 4-pole (80 dB per decade, 24 dB per octave) 2-pole (40 dB per decade, 12 dB per octave) (Height x Widthx Depth) 241.3 mm x 24.4 mm x 241.8mm (9.50 in x 0.96 in x 9.52 in)
3500/42-04-00 3500/42-04-00 Proximitor Seismic Monitor -3 dB at 15.6 Hz -3 dB at 0.41 Hz Within ±0.33% of full-scale typical ±1% maximum +1% -3% with MTL 764(-) Zener External Barrier Exclusive of filters Velomitor sensor accuracy: 4-pole (80 dB per decade, 24 dB per octave) 2-pole (40 dB per decade, 12 dB per octave) (Height x Widthx Depth) 241.3 mm x 24.4 mm x 241.8mm (9.50 in x 0.96 in x 9.52 in)
3500/42-04-02 3500/42-04-02 Proximitor Seismic Monitor -3 dB at 15.6 Hz -3 dB at 0.41 Hz Within ±0.33% of full-scale typical ±1% maximum +1% -3% with MTL 764(-) Zener External Barrier Exclusive of filters Velomitor sensor accuracy: 4-pole (80 dB per decade, 24 dB per octave) 2-pole (40 dB per decade, 12 dB per octave) (Height x Widthx Depth) 241.3 mm x 24.4 mm x 241.8mm (9.50 in x 0.96 in x 9.52 in)

Frequently asked questions

What is the Bently Nevada 3500/42-06-01 and what does it do?

The Bently Nevada 3500/42-06-01 is a proximitor seismic monitor for the 3500 Machinery Protection System. It conditions field transducer signals into vibration and position measurements and compares them against user-programmable alarm setpoints within the 3500 rack.

What are the physical dimensions of the 3500/42-06-01?

The 3500/42-06-01 measures (Height x Widthx Depth) 241.3 mm x 24.4 mm x 241.8mm (9.50 in x 0.96 in x 9.52 in) and weighs It occupies a standard 3500 rack slot and installs on the rack backplane.

How is the 3500/42-06-01 installed and configured?

The 3500/42-06-01 mounts in a 3500 rack rear slot and draws power from the rack backplane. Channels are configured with 3500 Rack Configuration Software; alarm setpoints and full-scale ranges are set in software with no field calibration required.

Related & compatible parts

Bently Nevada · 330901 / 330902 / 330908 Series

330901-22-90-05-02-00

Bently Nevada 330901-22-90-05-02-00 Proximity Probes & Sensors. Total Length: 0.5 meter (20 in); Agency Approval: Not required.

Available on request

Bently Nevada · 3500

3500/77-03-00

Bently Nevada 3500/77-03-00 3500 System Module. Pressure I/O: 50 kΩ; Indicates when the: 3500/77M is operating properly.

Available on request

Bently Nevada · 3500

3500/61-02-02

Bently Nevada 3500/61-02-02 Temperature Monitors with Recorder Outputs. Bulkhead Rack: ±3 °C at 25 °C (±5.4 °F at…

Available on request

Bently Nevada

107770-02-02

Genuine Bently Nevada 107770-02-02 velocity transducer housing with 3/4-14 NPT mounting and 1/2-14 NPT explosion-proof cable exit, CENELEC…

In Stock

News & guides for Bently Nevada

View all articles

Request a quote for this part

Part number: 3500/42-06-01

We reply within one business day.

3500/42-06-01 Quote reply within 1 business day