Technical specifications

Measurement Range 200-30000 mm
Measurement Principle HDDM™ Optical Time-of-Flight
Measurement Accuracy Typ. ± 7 mm
Light Source Visible red laser diode, 658 nm, Class 1
Supply Voltage 10-30 VDC
Electrical Connection Male connector M12, 5-pin
Enclosure Protection Rating IP65, IP67 (EN 60529)
Operating Temperature -40 °C ... +65 °C
Device Weight Approx. 235 g

Description

The SICK DT50-2B215552 is a Distance Sensor for industrial control and automation applications.

The SICK DT50-2B215552 is a mid-range distance sensor from the Dx50-2 series that measures from 200 mm to 30,000 mm using HDDM optical time-of-flight technology. Maintenance teams and integrators choose genuine surplus units of this model when they need a verified replacement without waiting on OEM lead times. It delivers Class 1 eye-safe laser measurement with a typical accuracy of ± 7 mm.

What This Distance Sensor Does in a System

this sensor belongs to the SICK Dx50-2 Next Generation family. Its HDDM measurement principle uses a visible red laser diode at 658 nm to calculate distance across the full 200 mm to 30,000 mm range. Because the laser is Class 1 per IEC 60825-1:2014, it is eye-safe during normal operation. The sensor provides a configurable analog output of 4 mA to 20 mA or 0 V to 10 V, plus a push-pull digital output and IO-Link V1.1 communication. A multifunctional input adds further control flexibility. The M12 5-pin male connector simplifies wiring into existing harnesses. The zinc die-cast housing with acrylic glass optical window measures 36.2 mm x 67.3 mm x 58 mm and weighs approximately 235 g.

Figure 1: Front view of the SICK DT50-2B215552 Distance Sensor showing its physical design and enclosure.

Why Genuine Surplus Makes Sense for This Model

When a this sensor fails on a running line, the priority is a verified replacement that matches the original specification. Autronexa supplies genuine surplus and refurbished SICK units that are tested against OEM datasheet specifications and functionally verified before dispatch. That approach gives you a practical alternative to waiting on factory lead times for a new-build unit. Each sensor is checked for the correct part number and configuration, so you receive the Dx50-2 variant you ordered. For maintenance managers, this means less time spent chasing availability and more confidence in the spare on the shelf.

Figure 2: Technical layout and connection details for the SICK DT50-2B215552 Distance Sensor.

Key Specifications Buyers Should Confirm

Before ordering, confirm that the 200 mm to 30,000 mm measuring range suits your application. Note that the protective range varies with target remission: 30,000 mm at 90% remission, 15,000 mm at 18%, and 7,000 mm at 6%. The supply voltage must fall within 10 VDC to 30 VDC, and power consumption is ≤ 2.1 W. The sensor operates from -40 °C to +65 °C and stores from -40 °C to +75 °C. Its IP65 and IP67 ratings suit washdown and dusty environments. Response time is configurable from 0.83 ms to 75 ms depending on speed settings, and repeatability ranges from ≥ 0.5 mm to 5 mm. Verify the M12 5-pin connector matches your cabling, and confirm whether you need the analog, digital, or IO-Link output path.

Frequently asked questions

Is the SICK DT50-2B215552 a genuine SICK unit or a clone?

Autronexa verifies each SICK DT50-2B215552 against OEM datasheet markings and part-number cross-reference before listing. We supply genuine surplus and refurbished units, not grey-market copies.

What condition will the DT50-2B215552 arrive in?

The DT50-2B215552 is supplied as refurbished unless otherwise stated. Our sourcing team tests each unit against OEM datasheet specifications and functionally verifies it before dispatch.

How fast can Autronexa ship the DT50-2B215552?

Lead time for the SICK DT50-2B215552 depends on current verified stock. Contact Autronexa with your part number for current availability and lead time.

Does the DT50-2B215552 support IO-Link?

Yes. The SICK DT50-2B215552 provides IO-Link V1.1 communication, a push-pull digital output, and a configurable analog output of 4 mA to 20 mA or 0 V to 10 V.

Related & compatible parts

SICK

DL100-11AA2109

Genuine surplus SICK DL100-11AA2109 laser distance sensor with 60 m range, CANopen, and 15 m/s tracking for ASRS…

In Stock

SICK

DL100-12AA2109

Genuine surplus SICK DL100-12AA2109 laser sensor for ASRS positioning with 15 m/s tracking and ±2 mm accuracy. Verified…

In Stock

SICK

CLV621-1120

Genuine SICK CLV621-1120 connectors for reliable barcode scanner integration. Verified surplus and refurbished units with clear lead times…

In Stock

SICK

DL100-11AA2102

Genuine surplus SICK DL100-11AA2102 laser distance sensor for racking systems, offering 15 m/s tracking and PROFIBUS DP for…

In Stock

News & guides for SICK

View all articles

Request a quote for this part

Part number: DT50-2B215552

We reply within one business day.

DT50-2B215552 Quote reply within 1 business day