SICK I/O & Function Modules

SICK DT50-N2123

Digital Output: 1x NPN

Manufacturer: SICK Part Number: DT50-N2123

Genuine surplus SICK DT50-N2123 distance sensor with 1x NPN output, 13 m range, and Class 1 laser—verified and ready to ship.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Measuring Range 200 mm ... 13,000 mm (90% remission)
Measurement Principle HDDM™ Optical Time-of-Flight
Repeatability ≥ 1 mm
Measurement Accuracy Typ. ± 7 mm
Supply Voltage DC 10 V ... 30 V
Output Interface 1x NPN (≤ 100 mA); 1x current output (4 mA ... 20 mA)
Response Time 15 ms / 30 ms / 80 ms (selectable)
Enclosure Protection Rating IP65 (EN 60529)
Operating Temperature -30 °C ... +65 °C
Dimensions (W x H x D) 36.1 mm x 62.7 mm x 57.7 mm

Description

The SICK DT50-N2123 is a Digital Output: 1x NPN for industrial control and automation applications.

The SICK DT50-N2123 is a digital output distance sensor from the Dx50 series, featuring a 1x NPN output and a measuring range up to 13,000 mm. For maintenance teams, a genuine surplus unit delivers verified performance without the long lead times of new OEM orders.

Product Overview

This sensor uses HDDM™ optical time-of-flight measurement to deliver repeatability of ≥ 1 mm and typical accuracy of ± 7 mm. The visible red laser (658 nm) is Class 1 eye-safe per IEC 60825-1:2014, so it suits open production areas without extra guarding. Response time is selectable at 15 ms, 30 ms, or 80 ms, letting you balance speed against signal stability for your process. The zinc die-cast housing (ZNAL4CU1) with PMMA window and IP65 rating handles dusty or washdown-adjacent environments.

Figure 1: Front view of the SICK DT50-N2123 Digital Output: 1x NPN showing its physical design and enclosure.

Surplus Advantage

New OEM lead times can stretch weeks, and every day of downtime erodes margin. Autronexa stocks genuine surplus and refurbished this unit units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. You get a practical alternative to full list price without sacrificing authenticity. The 1x NPN output (≤ 100 mA) and 4 mA … 20 mA analog output (≤ 300 Ω, 16-bit) cover common PLC input cards, reducing integration cost. Supply voltage of DC 10 V … 30 V with reverse-polarity protection adds robustness in real panels. Contact Autronexa with your part number for verified condition and current availability.

Figure 2: Technical layout and connection details for the SICK DT50-N2123 Digital Output: 1x NPN.

Selection & Sourcing Guide

Before ordering, confirm the exact model and output configuration: This unit provides 1x NPN digital output, while other Dx50 variants may differ. Check that your application’s range and remission match the sensor’s specifications—200 mm … 13,000 mm at 90% remission, 200 mm … 5,800 mm at 18%, and 200 mm … 3,400 mm at 6%. The M12 5-pin male connector is standard, so verify your cable assembly. For high-temperature zones, the standard operating range is -30 °C … +65 °C; cooling plates extend it to +80 °C or +140 °C, but confirm accessory compatibility. Autronexa helps you match the right revision and condition—surplus or refurbished—so you avoid costly missteps. Request a quote with your exact part number.

Frequently asked questions

Is the SICK DT50-N2123 a genuine SICK product or a clone?

Autronexa verifies every SICK DT50-N2123 unit against OEM datasheet markings and part-number cross-references. We source only genuine surplus and refurbished components, so you receive authentic SICK quality.

What condition will the SICK DT50-N2123 arrive in?

Our default condition for this model is refurbished, meaning it is tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available—contact us for current stock and grading.

How fast can you ship the SICK DT50-N2123?

Lead time depends on current stock. Contact Autronexa for a precise lead time and availability update for the SICK DT50-N2123.

Does the SICK DT50-N2123 work with my PLC?

The SICK DT50-N2123 provides a 1x NPN digital output (≤ 100 mA) and a 4 mA ... 20 mA analog output. Check your PLC input compatibility; our team can help confirm wiring requirements.

Related & compatible parts

SICK

DL50-N2228

Genuine surplus SICK DL50-N2228 laser distance sensor with 200 mm to 50,000 mm range, 100 µm resolution and…

In Stock

SICK

CLV650-6000

Genuine surplus SICK CLV650-6000 barcode scanner with oscillating mirror, 600–1,000 Hz scan rate, and IP65 housing — verified…

In Stock

SICK · Dx50

DL50-2B215252

Retro-reflective measurement up to 50 m on reflective tape Advanced HDDM™ time-of-flight technology offering high measuring rate up…

Available on request

SICK

BEF-FA-036-100

Genuine SICK BEF-FA-036-100 aluminum flange adapter — verified surplus and refurbished units for 36 mm to 100 mm…

In Stock

News & guides for SICK

View all articles

Request a quote for this part

Part number: DT50-N2123

We reply within one business day.

DT50-N2123 Quote reply within 1 business day