SICK I/O & Function Modules

SICK DT500-A112

Analog Output: 1x Current output

Manufacturer: SICK Part Number: DT500-A112

Genuine SICK DT500-A112 surplus laser distance sensor with 0.2–30 m range, 4–20 mA output, and IP65 housing — verified and ready to ship.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Measuring Range 0.2 m ... 30 m (90% white remission); 0.8 m ... 15 m (6% black remission)
Measurement Principle Pulsed optical laser time-of-flight
Light Source Visible red laser diode, 650 nm, Class 2 (IEC 60825-1:2014)
Measurement Accuracy Typ. ±3 mm ... ±10 mm
Repeatability 3 mm ... 5 mm
Response Time 250 ms (Fast mode) / 1,000 ms (Standard mode)
Output Interface 1x current output (4 mA ... 20 mA, ≤500 Ω); RS-422; 1x PNP MF
Supply Voltage DC 10 V ... 30 V (reverse-polarity protected)
Enclosure Rating IP65 (EN 60529)
Dimensions (W x H x D) 69 mm x 50 mm x 153 mm

Description

The SICK DT500-A112 is a Analog Output: 1x Current output for industrial control and automation applications.

The SICK DT500-A112 is a pulsed optical laser time-of-flight distance sensor from the Dx500 Standard family, offering a 0.2 m to 30 m measuring range on 90% white remission surfaces and a 4 mA to 20 mA current output. Maintenance teams choose genuine surplus or refurbished units of this model to restore measurement reliability without waiting on OEM lead times.

What this unit Measures and How It Fits Your Line

This sensor uses a visible red laser diode at 650 nm, Class 2 per IEC 60825-1:2014, with average optical power below 1 mW. It measures distance to natural surfaces without a reflector, covering 0.2 m to 30 m on white targets and 0.8 m to 15 m on 6% black remission targets. Typical accuracy is ±3 mm to ±10 mm, and repeatability is 3 mm to 5 mm. Response time is selectable at 250 ms in Fast mode or 1,000 ms in Standard mode. The front panel display and keypad allow on-site setup without a laptop, which simplifies commissioning and service checks.

Figure 1: Front view of the SICK DT500-A112 Analog Output: 1x Current output showing its physical design and enclosure.

Electrical and Mechanical Details for Service Planning

this unit runs on DC 10 V to 30 V with reverse-polarity protection and draws ≤3.5 W to 4 W without load. The electrical connection is a male M12 5-pin connector, and the output interface includes one current output (4 mA to 20 mA, ≤500 Ω) plus an RS-422 serial interface and one PNP MF output. The heavy-duty aluminum die-cast housing measures 69 mm x 50 mm x 153 mm and weighs approximately 1,000 g. Enclosure protection is IP65 per EN 60529, and operating ambient temperature ranges from -10 °C to +45 °C, with storage from -25 °C to +75 °C.

Figure 2: Technical layout and connection details for the SICK DT500-A112 Analog Output: 1x Current output.

Why Genuine Surplus Makes Sense for This Sensor

When a this unit fails, production lines that depend on continuous distance feedback can stall quickly. Autronexa supplies genuine surplus and refurbished units that are verified against OEM datasheet markings and functionally tested by our sourcing team. Refurbished units are checked against the original specifications, including the 4 mA to 20 mA output and the 0.2 m to 30 m range. Because these sensors are often pulled from decommissioned systems, availability can be faster than ordering new from the OEM. For maintenance engineers, that means a practical path to restore measurement without redesigning the mounting or wiring. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is the SICK DT500-A112 a genuine SICK unit or a clone?

Autronexa verifies every SICK DT500-A112 against OEM datasheet markings and part-number cross-reference before listing. We supply genuine surplus and refurbished units, not grey-market copies.

What condition will the DT500-A112 arrive in?

The SICK DT500-A112 is supplied as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available depending on stock.

How fast can Autronexa ship the DT500-A112?

Lead time for the SICK DT500-A112 depends on current stock. Contact Autronexa for a verified lead time and availability before placing your order.

Does the DT500-A112 work with my existing 4–20 mA input card?

The SICK DT500-A112 provides one current output of 4 mA to 20 mA with a maximum load of 500 Ω. Confirm your input card's compliance voltage and wiring with your controls engineer.

Related & compatible parts

SICK

DL100-11AA2110

Genuine surplus SICK DL100-11AA2110 laser distance sensor with 60 m range, EtherNet/IP dual-port and 15 m/s tracking for…

In Stock

SICK

C4C-SA10530A10000

Genuine SICK C4C-SA10530A10000 deTec4 Core sender light curtain, 1,050 mm protective field, 30 mm resolution, M12 5-pin connector.…

In Stock

SICK

DL100-12AA2102

Genuine surplus SICK DL100-12AA2102 laser distance sensor with 130 m range and PROFIBUS DP, verified and ready for…

In Stock

SICK

S30A-6011AA

Genuine SICK S30A-6011AA safety laser scanner for cold storage — 5.5 m protective field, IP67, and verified surplus…

In Stock

News & guides for SICK

View all articles

Request a quote for this part

Part number: DT500-A112

We reply within one business day.

DT500-A112 Quote reply within 1 business day