SICK I/O & Function Modules

SICK C4C-SA10530A10000

Impressive

Manufacturer: SICK Part Number: C4C-SA10530A10000

Genuine SICK C4C-SA10530A10000 deTec4 Core sender light curtain, 1,050 mm protective field, 30 mm resolution, M12 5-pin connector. Verified surplus sourcing from Autronexa.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Protective Field Height 1,050 mm
Resolution 30 mm
Scanning Range 15 m
Response Time 11 ms
Supply Voltage 24 V DC
Connector Type M12, 5-pin male
Enclosure Rating IP65 / IP67
Ambient Operating Temperature –30 °C to +55 °C
Housing Material Aluminum extruded profile
Weight 970 g

Description

When a safety light curtain fails on a guarded production line, restarting the cell safely becomes the priority. The SICK C4C-SA10530A10000 is a deTec4 Core sender unit with a 1,050 mm protective field height and 30 mm resolution, supplied as a genuine surplus or refurbished component with verified condition. Engineers specify this sender because it pairs with the matching receiver to restore Type 4 hand protection without waiting on OEM lead times.

What the deTec4 Core Sender Does in a Guarding System

The C4C-SA10530A10000 is the sender half of a deTec4 Core safety light curtain pair. It emits an infrared beam field across a 1,050 mm protective height, and the companion receiver evaluates the beam interruption. The 30 mm resolution suits hand detection at the guarded opening, while the 15 m scanning range covers most machine envelopes. Because the unit uses optical synchronisation, no separate sync cable runs between sender and receiver. The M12 5-pin male connector carries supply and signal to the evaluation device. A single sender is not a complete curtain, so confirm the receiver part number before ordering.

Figure 1: Front view of the SICK C4C-SA10530A10000 Impressive showing its physical design and enclosure.

Key Specifications That Drive Selection

Three values matter most when matching this sender to an existing guard. First, the 1,050 mm protective field height defines the vertical coverage; measure the opening rather than assuming a standard size. Second, the 30 mm resolution sets the smallest detectable object, which determines whether the guard suits hand or finger protection. Third, the 15 m scanning range gives installation flexibility on larger frames. The sender operates from 24 V DC and carries IP65 and IP67 enclosure ratings for washdown or dusty areas. Ambient operating temperature spans –30 °C to +55 °C, so cold-storage and outdoor enclosures are workable. Response time is 11 ms, which matters when calculating safety distance.

Figure 2: Technical layout and connection details for the SICK C4C-SA10530A10000 Impressive.

Why Genuine Surplus Makes Sense for This Sender

Safety components are rarely stockpiled, so a failed sender can idle a guarded cell while a new unit ships. Autronexa holds genuine surplus and refurbished deTec4 Core units that are tested against OEM datasheet specifications and functionally verified before dispatch. That approach gives maintenance teams a practical alternative to full OEM list pricing without accepting unverified grey-market stock. Each unit is checked for the correct model marking and connector configuration. For engineers maintaining several machines, keeping a verified spare sender on the shelf shortens recovery time on the next fault.

Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: C4C-SA10530A10000-datasheet.pdf

Frequently asked questions

Is the SICK C4C-SA10530A10000 a genuine SICK part or a copy?

Autronexa supplies genuine surplus and refurbished SICK components. Each C4C-SA10530A10000 sender is checked against OEM datasheet markings and the part number before it is listed.

What condition will the C4C-SA10530A10000 arrive in?

Units are supplied as refurbished unless otherwise stated. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch.

How fast can Autronexa ship the C4C-SA10530A10000?

Lead time depends on current stock. Contact Autronexa for the present lead time and availability of this deTec4 Core sender.

Does this sender work with my existing deTec4 Core receiver?

The C4C-SA10530A10000 is the sender half of a pair. Confirm the receiver part number and the 1,050 mm protective field height match your installation before ordering.

Related & compatible parts

SICK

DL100-12AA2109

Genuine surplus SICK DL100-12AA2109 laser sensor for ASRS positioning with 15 m/s tracking and ±2 mm accuracy. Verified…

In Stock

SICK

DT50-N2123

Genuine surplus SICK DT50-N2123 distance sensor with 1x NPN output, 13 m range, and Class 1 laser—verified and…

In Stock

SICK

DFS60B-S1MA10000

Genuine SICK DFS60B-S1MA10000 incremental encoder with 10,000 PPR and 6 x 10 mm shaft — verified surplus stock…

In Stock

SICK

S30B-3011CA

Genuine SICK S30B-3011CA safety laser scanner with 8 m range and IP65 rating. Verified surplus stock for fast,…

In Stock

News & guides for SICK

View all articles

Request a quote for this part

Part number: C4C-SA10530A10000

We reply within one business day.

C4C-SA10530A10000 Quote reply within 1 business day