Lenze E82CV751K2C
Replaced by a bare metal cooling plate connected to a separate customer-side
Genuine surplus Lenze E82CV751K2C cold-plate inverter: 0.75 kW, 4.0 A, IP20. Verified condition and practical sourcing support from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated motor power | 0.75 kW typical (4-pole three-phase asynchronous motor) |
|---|---|
| Rated output current | 4.0 A nominal at 8 kHz switching frequency |
| Max. output current | 6.0 A for 60 s (1 min overload at Imax / 2 min base load at 75% Ir) |
| Supply voltage | 1/N/PE or 3/PE AC 180 V -0% … 264 V +0%; 45 … 65 Hz |
| Operating temperature | -10 … +55 °C (derated by 2.5%/°C above +40 °C) |
| Storage temperature | -25 … +60 °C |
| Protection rating | IP20 |
| Built-in ports | X3 control terminal strip (analog/digital I/O) |
| Communication expansion | FIF slot for plug-in function modules (E82ZAF* family) |
| Protocols | None built-in (fieldbus requires plug-in function module) |
Description
The Lenze E82CV751K2C is a 0.75 kW frequency inverter from the 8200 vector series in cold-plate special design, where the heatsink is replaced by a bare metal cooling plate connected to a separate customer-side cooler. Maintenance and procurement teams choose genuine surplus or refurbished units when this configuration is needed for a running machine and OEM lead times are impractical.
What Does the Cold-Plate Design Solve?
In cabinets where heat removal happens through a separate cooling circuit, a standard heatsink can be the wrong fit. This unit addresses that by transferring loss heat through the cooling plate to the customer-side cooler. The dissipated power loss is 40 W, and thermal resistance between cooler and cooling medium is Rth ≤ 1.0 K/W. The maximum permissible cooling-plate temperature is 75 °C. Because the plate replaces the heatsink, published numerical dimensions and weight do not apply to this variant; mounting follows the cold-plate dimension drawings. This unit is rated IP20 and operates from -10 … +55 °C, derated by 2.5%/°C above +40 °C.

Which Drive Specs Matter on the Production Floor?
This unit delivers 0.75 kW typical for a 4-pole three-phase asynchronous motor, with 4.0 A nominal output current at 8 kHz switching frequency. For short load peaks it supplies 6.0 A for 60 s, following a periodic cycle of 1 min overload at Imax and 2 min base load at 75% Ir. Supply voltage is 1/N/PE or 3/PE AC 180 V -0% … 264 V +0% at 45 … 65 Hz. Control covers V/f characteristic (linear/quadratic) and sensorless vector control, with an output frequency range of -650 … +650 Hz. An integrated brake transistor and built-in I/O — 1 analog input, 1 analog output, 4 digital inputs, 1 digital output and 1 relay output (changeover contact, 250 V AC / 3 A) — support practical machine integration.

Why Source This Model as Genuine Surplus?
Lenze lists the 8200 vector among its previous products, and the cold-plate special design is available on request. There is no drop-in same-order-code replacement; Lenze confirms the i950 emulates 8200 vector behaviour via the i950 PROFIBUS module and L_ICIP library. For a running machine, matching the existing order code matters more than migrating. Autronexa supplies genuine surplus and refurbished units with verified condition and clear lead times, so you can keep the existing drive configuration in service. Built-in fieldbus is absent — the FIF slot accepts E82ZAF* plug-in function modules, so confirm the module you need before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is the Lenze E82CV751K2C a genuine Lenze unit or a clone?
Autronexa verifies units against OEM datasheet markings and part-number cross-reference before offering them. The E82CV751K2C is supplied as a genuine Lenze 8200 vector cold-plate inverter, not a copy.
What condition will the E82CV751K2C arrive in?
Autronexa supplies the E82CV751K2C as refurbished by default, tested against OEM datasheet specifications and functionally verified by the sourcing team. Confirm the condition grade you require when requesting the part.
How fast can Autronexa ship the E82CV751K2C?
Lead time depends on current verified stock. Contact Autronexa with the E82CV751K2C part number for current availability and lead time before committing to a maintenance window.
Does the E82CV751K2C include a built-in fieldbus port?
No. The Lenze E82CV751K2C has no built-in protocol; fieldbus communication requires a plug-in function module in the FIF slot from the E82ZAF* family. Confirm the required module separately.
Related & compatible parts
Lenze
E82CV223K4B201
Genuine surplus Lenze E82CV223K4B201 cold-plate inverter: 22 kW, 47 A, IP20. Verified condition and practical sourcing support from…
Lenze
E82CV222K4C
Genuine surplus Lenze E82CV222K4C cold-plate inverter: 2.2 kW, 5.6 A, IP20. Verified condition and practical sourcing support from…
Lenze
ERBP027R200W
Genuine surplus Lenze ERBP027R200W brake resistor: 27 Ω, 200 W continuous braking, 800 V DC maximum, with integrated…
Lenze
ESMD752L4TXA
Genuine Lenze ESMD752L4TXA frequency inverter, 7.5 kW, IP 20, 0–500 Hz output. Verified surplus and refurbished units with…
News & guides for Lenze
Lenze spare parts: buying guide, series overview and how to order
Lenze spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…