Flexem Vibration Monitoring FPad Series
Flexem FPad712
Vibration Monitoring
12.1-inch 16:10 web-based HMI panel with 1280×800 resolution, quad-A72/quad-A53 CPU, dual Gigabit Ethernet, and Linux OS.
- New Surplus
- Available on request
Availability & pricing
| Condition | Price | Stock / lead time | Action |
|---|---|---|---|
| New Surplus | On request | Available on request |
Ships within 7 business days
Technical specifications
| Model | FPad712 |
|---|---|
| Brand | Flexem |
| Series | FPad Series |
| CPU | 4×Cortex-A72 + 4×Cortex-A53, up to 2.2 GHz |
| Memory | 2 GB DDR4 + 16 GB eMMC |
| OS | Linux |
| SD card slot | Not available |
| Real-time clock | Built-in |
| Programming software | FStudio Unified |
| Display | 12.1" 16:10 TFT LCD |
| Resolution | 1280×800 |
| Colors | 24-bit |
| Brightness | 400 cd/m² |
| Viewing angles (T/B/L/R) | 80°/80°/80°/80° |
| Touch panel | 4-wire industrial resistive touchscreen |
| Backlight | LED |
| LCD lifetime | 50,000 hours |
| Built-in ports | 2×Gigabit RJ45 (10/100/1000 Mbps auto-adaptive); 2×USB 3.0 Type-A; COM1 (RS232/RS485/RS422); COM2 (RS485/RS422); COM3 (RS232) |
| Protocols | Not published in official datasheet |
| Communication expansion | None |
| Supply voltage | DC 24V nominal, operating range DC 18–28V |
| Power consumption | <15W maximum |
| Power protection | Lightning surge protection |
| Power interruption tolerance | <5 ms |
| EMC | EN61000-6-2:2019, EN61000-6-4:2019, RoHS; lightning surge ±1 kV, group pulse ±2 kV; electrostatic contact 4 kV, air discharge 8 kV |
| Operating temperature | -10 to 60 °C |
| Storage temperature | -20 to 70 °C |
| Relative humidity | 10 to 90 %RH (non-condensing) |
| Protection rating | Front IP65, rear IP20 |
| Vibration endurance | 10–25 Hz (X/Y/Z direction, 2G/30 min) |
| UV resistance | Not for use in high UV environments |
| Cooling | Natural convection |
| Dimensions (H×W×D) | 228×313×38 mm |
| Panel cutout (W×H) | 295×217 mm |
| Weight | ~2.30 kg (about 2300 g, supplier-reported) |
| Enclosure | Non-ferrous alloy |
| Installation | Flush mount / VESA mount |
Description
The FPad712 is a catalog part supplied for replacement and new-build use in industrial control installations. Every rating below is taken from the manufacturer documentation for this part number. Headline figures: supply voltage DC 24V nominal, operating range DC 18–28V; weight ~2.30 kg (about 2300 g, supplier-reported); operating temperature -10 to 60 °C
Electrical Ratings
Supply voltage is DC 24V nominal, operating range DC 18–28V. match this against the supply available at the installation site, including any tolerance on the incoming feed. Power consumption is <15W maximum. size the power supply and the rack load around this figure; it is the draw the part places on the supply it is installed in. Power protection is Lightning surge protection. this describes how the part behaves during supply disturbances, which matters where an outage must not cause an unplanned trip. Power interruption tolerance is <5 ms. this describes how the part behaves during supply disturbances, which matters where an outage must not cause an unplanned trip. UV resistance is Not for use in high UV environments. compare this against the requirement it must satisfy in the application before release to site.
Mechanical & Dimensional Data
Dimensions (H×W×D) is 228×313×38 mm. take this measurement into account when setting panel depth, rail position or enclosure clearance, since oversize is the normal reason a correct part will not physically fit. Weight is ~2.30 kg (about 2300 g, supplier-reported). factor this into lifting, rail-loading and shipping decisions; it is also the figure to quote when a handling study is required. Enclosure is Non-ferrous alloy. the material determines corrosion behaviour and thermal performance in the installed environment.
Environmental & Compliance Ratings
Operating temperature is -10 to 60 °C. check the enclosure temperature at the planned mounting location stays inside this band during the hottest operating period. Storage temperature is -20 to 70 °C. observe this figure during transport and warehouse storage, which are not the same condition as operation. Relative humidity is 10 to 90 %RH (non-condensing). maintain the stated humidity range in the cabinet; condensation is the usual cause of failure in equipment installed in humid plant rooms. Vibration endurance is 10–25 Hz (X/Y/Z direction, 2G/30 min). confirm the installed location falls within this environmental capability.
Additional Verified Data
CPU is 4×Cortex-A72 + 4×Cortex-A53, up to 2.2 GHz. Memory is 2 GB DDR4 + 16 GB eMMC. OS is Linux. Real-time clock is Built-in. Programming software is FStudio Unified. Display is 12.1" 16:10 TFT LCD. Resolution is 1280×800. Colors is 24-bit. Brightness is 400 cd/m². Viewing angles (T/B/L/R) is 80°/80°/80°/80°. Touch panel is 4-wire industrial resistive touchscreen. Backlight is LED. LCD lifetime is 50,000 hours. Built-in ports is 2×Gigabit RJ45 (10/100/1000 Mbps auto-adaptive); 2×USB 3.0 Type-A; COM1 (RS232/RS485/RS422); COM2 (RS485/RS422); COM3 (RS232). EMC is EN61000-6-2:2019, EN61000-6-4:2019, RoHS; lightning surge ±1 kV, group pulse ±2 kV; electrostatic contact 4 kV, air discharge 8 kV. Protection rating is Front IP65, rear IP20. Panel cutout (W×H) is 295×217 mm. Installation is Flush mount / VESA mount.
Models in This Series
Autronexa currently lists this product entry as the only model in its entry. Cross-reference requests for equivalent or superseded part numbers are handled on request.
Confirming the Correct Variant Before Ordering
Read the part number marked on the unit being replaced and compare it character by character with the ordering code above, including any option suffix. Check the values in the technical specification table of this page against the nameplate on the existing unit rather than against a previous purchase record. Confirm the supply voltage available at the installation site is DC 24V nominal, operating range DC 18–28V, which is the documented requirement for this model.
Request a Quote
Autronexa supplies the FPad712 as a quote-based item. Send the part number, quantity and destination for current stock, lead time and pricing; no fixed price is published for this part.
Frequently asked questions
What is the FPad712?
Flexem FPad712 is an industrial automation component we supply from surplus and refurbished stock. Confirm the exact configuration, condition and lead time with our team before purchase.
Is the FPad712 in stock, and what is the lead time?
We list the FPad712 as in stock in New Surplus condition. Request a quote for current availability, pricing and confirmed lead time — most items ship within 1–3 business days.
Do you provide a datasheet for the FPad712?
Where available, the product page links the original manufacturer datasheet (PDF). Use the request-a-quote form to receive the full documentation pack and compliance information.
Can the FPad712 be cross-referenced to an equivalent?
Many automation parts have equivalents or legacy replacements. Send us the FPad712 together with your application details and we will confirm compatibility and alternatives.
What input voltage does the FPad712 use?
The FPad712 operates at DC 24V nominal, operating range DC 18–28V. Verify the exact range and any hazardous-area limits against the product label before installation, because input requirements vary by ordered variant.
What is the operating temperature range of the FPad712?
The FPad712 operating temperature is listed as -10 to 60 °C. Stay within the documented band during operation; storage limits may differ. Elevated ambient conditions can reduce the continuous current or power rating of the module.
What are the dimensions and weight of the FPad712?
The FPad712 measures 228×313×38 mm and weighs ~2.30 kg (about 2300 g, supplier-reported). Confirm clearance and rack or panel space before ordering.
What is the FPad712 and what is it used for?
The FPad712 is a industrial component device. It is used in industrial control and automation systems where a verified part number and specification match are required for replacement or new design.
What supply voltage does the FPad712 need?
The manufacturer documentation lists supply voltage DC 24V nominal, operating range DC 18–28V. for this model. Confirm the supply at the installation site matches, including any tolerance on the incoming feed, before the part is ordered.
How much does the FPad712 weigh?
The documented weight is ~2.30 kg (about 2300 g, supplier-reported).. Use it for lifting, rail-loading and shipping decisions, and quote it when a handling study is required for the installation.
Related & compatible parts
Flexem
FE7070C
Genuine surplus Flexem FE7070C HMI panel with a 7-inch 800×480 resistive touchscreen, verified condition and practical sourcing support.
Flexem
FL8-E32-D
Genuine surplus Flexem FL8-E32-D CPU module with 32-axis EtherCAT control and 8 digital inputs for motion automation.
Flexem
FE6100WE
Genuine surplus Flexem FE6100WE 10.1-inch resistive HMI with Ethernet and 24V DC input, verified and ready to ship…
Flexem
F110
Genuine Flexem F110 HMI panel with 10.1" 1280×800 capacitive touch, dual-core CPU, and quad COM ports — verified…
News & guides for Flexem
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…