Honeywell I/O & Function Modules
Honeywell MLE-DR16A
MLE-DR16A: Digital Input
Genuine surplus Honeywell MLE-DR16A digital input and relay output module with 8 channels each, verified condition and clear lead times from Autronexa.
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
Technical specifications
| Input points | 8 points |
|---|---|
| Rated input voltage | DC24V |
| Rated input current | 4 mA |
| Operation voltage range | DC20.4~28.8V (ripple rate < 5%) |
| Input response time (default) | 3ms |
| Output points | 8 points |
| Relay output rating | DC 24V 2A (resistive load) / AC 220V 2A (Cos Ø = 1) |
| Max. load current | AC250V, DC125V |
| External connection | 9-pin terminal block connector |
| Weight | 81g |
Description
The Honeywell MLE-DR16A is a MLE-DR16A: Digital Input for industrial control and automation applications.
The Honeywell MLE-DR16A is a digital input and relay output module with 8 input channels rated for DC24V and 8 relay output channels, built for control panels that need reliable signal handling. Autronexa supplies this module as genuine surplus, verified before dispatch, so you get a practical replacement without the wait of a new-build order.
What this unit Does in a Control System
This module combines two functions in one unit: it accepts eight DC input signals and switches eight relay outputs. The input side uses a photo coupler insulation method and draws a rated input current of 4 mA at DC24V. Its operation voltage range is DC20.4~28.8V with a ripple rate below 5%, so it tolerates normal supply variation in industrial cabinets. The input resistance is 5.6 kΩ, and each input point shares a common method of 8 point / COM. On the output side, the relay contacts are rated for DC 24V 2A (resistive load) and AC 220V 2A (Cos Ø = 1), with a maximum load current of AC250V or DC125V. The module weighs 81g and connects through a 9-pin terminal block connector.

Response Times and Their Cost Impact
Response time settings affect how quickly a machine reacts to a sensor or command. This unit input response can be set by CPU parameter to 1ms, 3ms, 5ms, 10ms, 20ms, 70ms or 100ms for both Off-to-On and On-to-Off transitions, with a default of 3ms. The relay output response is 10ms or less Off-to-On and 12ms or less On-to-Off. For buyers, these values matter because a faster response can reduce scrap on high-speed lines, while a slower setting can filter chatter from mechanical contacts. Matching the response setting to the actual machine cycle helps avoid unnecessary rejects and keeps throughput predictable.

Why Genuine Surplus Makes Sense for This Module
this unit carries a mechanical service life of 20 million operations or more, and its electrical life is rated at 100,000 operations or more under defined load conditions. That durability means a verified surplus unit can still deliver substantial remaining life. Autronexa checks each module against OEM datasheet markings and confirms condition before shipping, which gives maintenance teams a practical alternative to waiting on a factory lead time. The module also includes an output-on LED indicator and an internal current consumption of 280mA, details that help you plan panel load and troubleshooting routines.
Sourcing Checklist Before You Order
Confirm the exact model number and terminal style your panel expects, since this unit uses a 9-pin terminal block connector. Check whether your CPU parameter settings require a specific input response time, and note the default of 3ms. Ask for the verified condition grade and current lead time before committing. Autronexa supports sourcing across Allen-Bradley, Bently Nevada, Siemens, Schneider and more, so you can consolidate spare-part requests. Share your part number with Autronexa and we will confirm verified condition and current availability.
Frequently asked questions
Is the Honeywell MLE-DR16A a genuine part or a clone?
Autronexa verifies each Honeywell MLE-DR16A against OEM datasheet markings and part-number cross-reference before listing it as genuine surplus.
What condition will the MLE-DR16A arrive in?
The Honeywell MLE-DR16A is supplied as genuine surplus or refurbished stock, and Autronexa confirms the verified condition grade with you before dispatch.
How fast can Autronexa ship the MLE-DR16A?
Lead time for the Honeywell MLE-DR16A depends on current stock, so contact Autronexa with your part number to confirm verified condition and current availability.
What input response time does the MLE-DR16A support?
The Honeywell MLE-DR16A input response can be set by CPU parameter to 1ms, 3ms, 5ms, 10ms, 20ms, 70ms or 100ms, with a default of 3ms.
Related & compatible parts
Honeywell
2MLQ-RY1A
Genuine surplus Honeywell 2MLQ-RY1A relay output module with 8 points and relay isolation. Verified condition, practical sourcing support.
Honeywell
2MLF-DC8A
Genuine surplus Honeywell 2MLF-DC8A analog output module with 8 current channels and selectable DC 4~20mA or DC 0~20mA…
Honeywell
TC-FIL081
Genuine surplus Honeywell TC-FIL081 thermocouple input: 8 channels, 16-bit resolution, and support for Type B through Type TXK/XK…
Honeywell
900R04-0300
Genuine surplus Honeywell 900R04-0300 4 I/O slot rack. Verified condition, practical sourcing for maintenance and procurement teams.
News & guides for Honeywell
Honeywell spare parts: buying guide, series overview and how to order
Honeywell spare parts buying guide: 3 parts online, popular series, condition options and how our RFQ process works.
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Siemens Kärnten Netz Grid Software Contract: Scope and Limits
TL;DR: On 9 November 2026 Siemens announced a six-year software contract with Kärnten Netz GmbH (KNG), the Carinthian distribution system…