Lenze I/O & Function Modules

Lenze E82CV152K4C

Replaced by a bare metal cooling plate connected to a separate customer-side

Manufacturer: Lenze Part Number: E82CV152K4C

Genuine surplus Lenze E82CV152K4C cold-plate inverter: 1.5 kW, 3.9 A, IP20. Verified condition and practical sourcing support from Autronexa.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Rated motor power 1.5 kW typical (4-pole three-phase asynchronous motor)
Rated output current 3.9 A nominal at 8 kHz switching frequency
Max. output current 5.9 A for 60 s (1 min overload at Imax / 2 min base load at 75 % Ir)
Supply voltage 3/PE AC 320 V -0% … 550 V +0%; 45 … 65 Hz
Operating temperature -10 … +55 °C (derated by 2.5 %/°C above +40 °C)
Storage temperature -25 … +60 °C
Protection rating IP20
Built-in ports X3 control terminal strip (analog/digital I/O)
Communication expansion FIF slot for plug-in function modules (E82ZAF* family)

Description

The Lenze E82CV152K4C is a 1.5 kW 8200 vector frequency inverter in cold-plate special design, where a bare metal cooling plate replaces the heatsink for connection to a customer-side cooler. Maintenance and procurement teams choose genuine surplus or refurbished units for this model because the cold-plate variant remains available only on request, and the official migration path to the i950 requires re-engineering rather than a drop-in swap.

What the Cold-Plate Design Changes for Your Panel

The E82CV152K4C removes the standard heatsink and relies on a bare metal cooling plate connected to a separate customer-side cooler. That arrangement suits enclosures where heat is routed to a shared liquid or cabinet cooling circuit instead of being dissipated inside the panel. The thermal data is central to cost planning: dissipated power loss is 65 W, thermal resistance between cooler and cooling medium is Rth ≤ 0.3 K/W, and the maximum permissible cooling-plate temperature is 75 °C. A correctly sized customer-side cooler therefore protects the inverter and avoids the cost of oversizing panel air conditioning. The unit is rated IP20 and operates from -10 to +55 °C, derated by 2.5 %/°C above +40 °C, so ambient headroom directly affects usable output.

Figure 1: Front view of the Lenze E82CV152K4C Replaced by a bare metal cooling plate connected to a separate customer-side showing its physical design and enclosure.

Electrical Ratings and Overload Cost

This unit delivers 1.5 kW typical for a 4-pole three-phase asynchronous motor, with 3.9 A nominal output current at 8 kHz switching frequency. Maximum output current is 5.9 A for 60 s under a periodic load cycle of 1 min overload at Imax and 2 min base load at 75 % Ir. That overload window covers many starts and short peaks without forcing a larger frame size, which keeps both purchase cost and panel space in check. Supply voltage is 3/PE AC 320 V -0% … 550 V +0% at 45 … 65 Hz, and an integrated brake transistor reduces the need for separate braking hardware. V/f characteristic control and sensorless vector control cover the output frequency range -650 … +650 Hz.

Figure 2: Technical layout and connection details for the Lenze E82CV152K4C Replaced by a bare metal cooling plate connected to a separate customer-side.

Control, Expansion and Sourcing Checks

The X3 control terminal strip provides analog and digital I/O, and no fieldbus protocol is built in; communication requires a plug-in function module in the FIF slot from the E82ZAF family. Budget for that module when comparing against a networked drive. Because this is a legacy cold-plate special design, verify the exact order code, condition and cooler interface before ordering. Autronexa supplies genuine surplus and refurbished units, verified against OEM datasheet markings, with practical help on the E82ZAF expansion path. Contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: E82CV152K4C-datasheet.pdf

Frequently asked questions

Is the Lenze E82CV152K4C a genuine part or a clone?

Autronexa verifies each unit against OEM datasheet markings and part-number cross-references before it is listed. The E82CV152K4C is supplied as genuine surplus or refurbished stock, not as a copy.

What condition will the E82CV152K4C arrive in?

Units are supplied refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask Autronexa to confirm the condition grade of the specific unit before you order.

How fast can Autronexa ship the E82CV152K4C?

Lead time depends on current stock. Contact Autronexa for the present lead time and availability of this cold-plate inverter.

Does the E82CV152K4C include a fieldbus port?

No. Protocols are not built in; fieldbus communication requires a plug-in function module in the FIF slot from the E82ZAF* family.

Is the E82CV152K4C still supported by Lenze?

Lenze lists the 8200 vector among its previous products, and the cold-plate special design is available on request. The official migration path is the i950, which emulates 8200 vector behaviour but is not a drop-in same-order-code replacement. Contact Autronexa to verify OEM support status.

Related & compatible parts

Lenze

ECSEP016C4B

Genuine surplus Lenze ECSEP016C4B ECS servo drive module, verified and refurbished. Sourcing help for this 16.0 A axis…

Quote on request

Lenze

E82CV551K2C

Genuine surplus Lenze E82CV551K2C cold-plate inverter: 0.55 kW, 3.0 A, IP20, verified condition and practical sourcing support.

In Stock

Lenze

ESMD152L4TXA

The ESMD152L4TXA component from Lenze is designed as a three-phase drive with a power rating of 1.5 kW.…

Available on request

Lenze

E94ASHE0864

Genuine surplus Lenze E94ASHE0864 axis module: 45 kW, 86 A rated output, CANopen onboard, IP20. Verified condition and…

Quote on request

News & guides for Lenze

View all articles

Request a quote for this part

Part number: E82CV152K4C

We reply within one business day.

E82CV152K4C Quote reply within 1 business day