Lenze E82CV551K2C
Replaced by a bare metal cooling plate connected to a separate customer-side
Genuine surplus Lenze E82CV551K2C cold-plate inverter: 0.55 kW, 3.0 A, IP20, verified condition and practical sourcing support.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated motor power | 0.55 kW typical (4-pole three-phase asynchronous motor) |
|---|---|
| Rated output current | 3.0 A nominal at 8 kHz switching frequency |
| Max. output current | 4.5 A for 60 s (1 min overload at Imax / 2 min base load at 75% Ir) |
| Supply voltage | 1/N/PE or 3/PE AC 180 V -0% … 264 V +0%; 45 … 65 Hz |
| Operating temperature | -10 … +55 °C (derated by 2.5%/°C above +40 °C) |
| Protection rating | IP20 |
| Cooling plate | Dissipated power loss 30 W; Rth ≤ 1.0 K/W; max. permissible plate temperature 75 °C |
| Built-in ports | X3 control terminal strip (analog/digital I/O) |
| Communication expansion | FIF slot for plug-in function modules (E82ZAF* family) |
Description
When a cold-plate inverter fails on a running machine, every hour of downtime adds cost. The Lenze E82CV551K2C is a genuine 8200 vector frequency inverter in cold-plate technology, rated 0.55 kW typical, and Autronexa supplies it as verified surplus or refurbished stock for maintenance and repair teams.
What the E82CV551K2C Does in an 8200 vector System
This unit belongs to the Lenze 8200 vector family, but its special design replaces the standard heatsink with a bare metal cooling plate. That plate connects to a separate customer-side cooler, so heat leaves through the mounting surface rather than through fins and forced air. The inverter delivers 3.0 A nominal output current at 8 kHz switching frequency and accepts a 1/N/PE or 3/PE AC supply from 180 V to 264 V at 45 to 65 Hz. Control covers V/f characteristic (linear or quadratic) and sensorless vector control, with an output frequency range of -650 to +650 Hz. Built-in I/O includes one analog input, one analog output, four digital inputs, one digital output and one relay changeover contact rated 250 V AC / 3 A. An integrated brake transistor supports braking duties without extra hardware.

Cold-Plate Thermal Limits and Service Checks
For maintenance engineers, the cooling path is the first thing to inspect. This unit dissipates 30 W, and thermal resistance between cooler and cooling medium must stay at or below 1.0 K/W. The maximum permissible cooling-plate temperature is 75 °C. Keep the plate surface clean and confirm the customer-side cooler is delivering flow before returning the drive to service. The inverter is rated IP20 and operates from -10 to +55 °C, derated by 2.5 %/°C above +40 °C, so cabinet ventilation matters. Storage range is -25 to +60 °C at an average 85 % RH without condensation. Fieldbus is not built in; the FIF slot accepts E82ZAF* plug-in function modules when network control is needed.

Why Genuine Surplus Fits This Legacy Drive
Lenze lists the 8200 vector among its previous products, and the cold-plate special design is available on request. There is no drop-in same-order-code replacement, and the official migration path to the i950 requires engineering work. That makes verified surplus and refurbished units a practical route for keeping existing machines running. Autronexa checks each unit against OEM datasheet markings and part-number cross-reference, and refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Lenze E82CV551K2C, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it is listed. The E82CV551K2C is supplied as genuine surplus or refurbished stock, not as a copy.
What condition will the E82CV551K2C arrive in?
Units are supplied as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask Autronexa for the specific condition grade of the unit in stock.
How fast can you ship the E82CV551K2C?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability before ordering.
Does the E82CV551K2C need an external cooler to run?
Yes. The standard heatsink is replaced by a bare metal cooling plate that connects to a separate customer-side cooler. Thermal resistance must stay at or below 1.0 K/W, and the plate temperature must not exceed 75 °C.
Is the Lenze 8200 vector still supported by Lenze?
Lenze lists the 8200 vector among its previous products, and the cold-plate special design is available on request. There is no drop-in same-order-code replacement; the official migration path is to the i950. Verify current lifecycle status with Autronexa before ordering.
Related & compatible parts
Lenze
E82CV751K2C
Genuine surplus Lenze E82CV751K2C cold-plate inverter: 0.75 kW, 4.0 A, IP20. Verified condition and practical sourcing support from…
Lenze
E94AYM22
Genuine surplus Lenze E94AYM22 memory module with 2 MB flash and CAN address switch for 9400 HighLine servo…
Lenze
I5DAE175F10010000S
Genuine surplus Lenze i550 inverter, 0.75 kW, 400/480 VAC three-phase, IP20. Verified condition and clear lead times from…
Lenze
EPM-S404
Genuine surplus Lenze EPM-S404 analog input module with four RTD channels, 16-bit resolution, and verified condition from Autronexa.
News & guides for Lenze
Lenze spare parts: buying guide, series overview and how to order
Lenze spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…